Cargando…

High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model

PURPOSE: To compare the biomechanical properties of high-tensile strength tape and a high-tensile strength suture in subpectoral biceps tenodesis using a suture anchor in a porcine tendon model. METHODS: A total of 24 artificial composite (polymer and glass fiber) humeri and porcine flexor profundus...

Descripción completa

Detalles Bibliográficos
Autores principales: Hong, Chih-Kai, Su, Wei-Ren, Kuan, Fa-Chuan, Chen, Yueh, Chiang, Chen-Hao, Hsu, Kai-Lan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7754602/
https://www.ncbi.nlm.nih.gov/pubmed/33376994
http://dx.doi.org/10.1016/j.asmr.2020.07.018
_version_ 1783626228909998080
author Hong, Chih-Kai
Su, Wei-Ren
Kuan, Fa-Chuan
Chen, Yueh
Chiang, Chen-Hao
Hsu, Kai-Lan
author_facet Hong, Chih-Kai
Su, Wei-Ren
Kuan, Fa-Chuan
Chen, Yueh
Chiang, Chen-Hao
Hsu, Kai-Lan
author_sort Hong, Chih-Kai
collection PubMed
description PURPOSE: To compare the biomechanical properties of high-tensile strength tape and a high-tensile strength suture in subpectoral biceps tenodesis using a suture anchor in a porcine tendon model. METHODS: A total of 24 artificial composite (polymer and glass fiber) humeri and porcine flexor profundus tendons were used. Two types of suture materials, high-tensile strength sutures (group S) and high-tensile strength tapes (group T), were evaluated. After we inserted metallic suture anchors with either 2 sutures or tapes 5 cm from the superomedial corner of the greater tuberosity, a Krackow suture technique was used to secure the tendons. After a preload of 5 N for 2 minutes, a cyclic loading test from 5 to 70 N was conducted for 500 cycles. Finally, the specimen was loaded to failure at a rate of 1 mm/s. RESULTS: There were no significant between-group differences in elongation after cyclic loading and elongation at failure load for group S and group T (P = .977 and .630, respectively). The ultimate failure loads in group T (278.2 ± 54 N) were significantly greater than those in group S (249.4 ± 32 N) (P = .028). In contrast, the stiffness values in group T (28.5 ± 4.0 N/mm) were significantly lower than those in group S (32.3 ± 4.5 N) (P = .028). Ten specimens in group S and 8 specimens in group T failed, with tendons being cut through by the sutures, whereas the other 2 specimens in group S and 4 specimens in group T failed due to suture breakage. CONCLUSIONS: Using high-tensile strength tapes in subpectoral biceps tenodesis using a suture anchor leads to significantly greater ultimate failure load as compared with using high-tensile strength sutures in a porcine model. Although lower levels of stiffness were found in high-tensile strength tape group, the difference in the means were not large between 2 groups. CLINICAL RELEVANCE: A strong suture–tendon structure may prevent clinical failure of a subpectoral biceps tenodesis using a suture anchor.
format Online
Article
Text
id pubmed-7754602
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-77546022020-12-28 High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model Hong, Chih-Kai Su, Wei-Ren Kuan, Fa-Chuan Chen, Yueh Chiang, Chen-Hao Hsu, Kai-Lan Arthrosc Sports Med Rehabil Original Article PURPOSE: To compare the biomechanical properties of high-tensile strength tape and a high-tensile strength suture in subpectoral biceps tenodesis using a suture anchor in a porcine tendon model. METHODS: A total of 24 artificial composite (polymer and glass fiber) humeri and porcine flexor profundus tendons were used. Two types of suture materials, high-tensile strength sutures (group S) and high-tensile strength tapes (group T), were evaluated. After we inserted metallic suture anchors with either 2 sutures or tapes 5 cm from the superomedial corner of the greater tuberosity, a Krackow suture technique was used to secure the tendons. After a preload of 5 N for 2 minutes, a cyclic loading test from 5 to 70 N was conducted for 500 cycles. Finally, the specimen was loaded to failure at a rate of 1 mm/s. RESULTS: There were no significant between-group differences in elongation after cyclic loading and elongation at failure load for group S and group T (P = .977 and .630, respectively). The ultimate failure loads in group T (278.2 ± 54 N) were significantly greater than those in group S (249.4 ± 32 N) (P = .028). In contrast, the stiffness values in group T (28.5 ± 4.0 N/mm) were significantly lower than those in group S (32.3 ± 4.5 N) (P = .028). Ten specimens in group S and 8 specimens in group T failed, with tendons being cut through by the sutures, whereas the other 2 specimens in group S and 4 specimens in group T failed due to suture breakage. CONCLUSIONS: Using high-tensile strength tapes in subpectoral biceps tenodesis using a suture anchor leads to significantly greater ultimate failure load as compared with using high-tensile strength sutures in a porcine model. Although lower levels of stiffness were found in high-tensile strength tape group, the difference in the means were not large between 2 groups. CLINICAL RELEVANCE: A strong suture–tendon structure may prevent clinical failure of a subpectoral biceps tenodesis using a suture anchor. Elsevier 2020-10-15 /pmc/articles/PMC7754602/ /pubmed/33376994 http://dx.doi.org/10.1016/j.asmr.2020.07.018 Text en © 2020 Published by Elsevier on behalf of the Arthroscopy Association of North America. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Hong, Chih-Kai
Su, Wei-Ren
Kuan, Fa-Chuan
Chen, Yueh
Chiang, Chen-Hao
Hsu, Kai-Lan
High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model
title High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model
title_full High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model
title_fullStr High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model
title_full_unstemmed High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model
title_short High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model
title_sort high-tensile strength tapes show greater ultimate failure load and less stiffness than high-tensile strength sutures in a subpectoral biceps tenodesis porcine model
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7754602/
https://www.ncbi.nlm.nih.gov/pubmed/33376994
http://dx.doi.org/10.1016/j.asmr.2020.07.018
work_keys_str_mv AT hongchihkai hightensilestrengthtapesshowgreaterultimatefailureloadandlessstiffnessthanhightensilestrengthsuturesinasubpectoralbicepstenodesisporcinemodel
AT suweiren hightensilestrengthtapesshowgreaterultimatefailureloadandlessstiffnessthanhightensilestrengthsuturesinasubpectoralbicepstenodesisporcinemodel
AT kuanfachuan hightensilestrengthtapesshowgreaterultimatefailureloadandlessstiffnessthanhightensilestrengthsuturesinasubpectoralbicepstenodesisporcinemodel
AT chenyueh hightensilestrengthtapesshowgreaterultimatefailureloadandlessstiffnessthanhightensilestrengthsuturesinasubpectoralbicepstenodesisporcinemodel
AT chiangchenhao hightensilestrengthtapesshowgreaterultimatefailureloadandlessstiffnessthanhightensilestrengthsuturesinasubpectoralbicepstenodesisporcinemodel
AT hsukailan hightensilestrengthtapesshowgreaterultimatefailureloadandlessstiffnessthanhightensilestrengthsuturesinasubpectoralbicepstenodesisporcinemodel