Cargando…
High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model
PURPOSE: To compare the biomechanical properties of high-tensile strength tape and a high-tensile strength suture in subpectoral biceps tenodesis using a suture anchor in a porcine tendon model. METHODS: A total of 24 artificial composite (polymer and glass fiber) humeri and porcine flexor profundus...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7754602/ https://www.ncbi.nlm.nih.gov/pubmed/33376994 http://dx.doi.org/10.1016/j.asmr.2020.07.018 |
_version_ | 1783626228909998080 |
---|---|
author | Hong, Chih-Kai Su, Wei-Ren Kuan, Fa-Chuan Chen, Yueh Chiang, Chen-Hao Hsu, Kai-Lan |
author_facet | Hong, Chih-Kai Su, Wei-Ren Kuan, Fa-Chuan Chen, Yueh Chiang, Chen-Hao Hsu, Kai-Lan |
author_sort | Hong, Chih-Kai |
collection | PubMed |
description | PURPOSE: To compare the biomechanical properties of high-tensile strength tape and a high-tensile strength suture in subpectoral biceps tenodesis using a suture anchor in a porcine tendon model. METHODS: A total of 24 artificial composite (polymer and glass fiber) humeri and porcine flexor profundus tendons were used. Two types of suture materials, high-tensile strength sutures (group S) and high-tensile strength tapes (group T), were evaluated. After we inserted metallic suture anchors with either 2 sutures or tapes 5 cm from the superomedial corner of the greater tuberosity, a Krackow suture technique was used to secure the tendons. After a preload of 5 N for 2 minutes, a cyclic loading test from 5 to 70 N was conducted for 500 cycles. Finally, the specimen was loaded to failure at a rate of 1 mm/s. RESULTS: There were no significant between-group differences in elongation after cyclic loading and elongation at failure load for group S and group T (P = .977 and .630, respectively). The ultimate failure loads in group T (278.2 ± 54 N) were significantly greater than those in group S (249.4 ± 32 N) (P = .028). In contrast, the stiffness values in group T (28.5 ± 4.0 N/mm) were significantly lower than those in group S (32.3 ± 4.5 N) (P = .028). Ten specimens in group S and 8 specimens in group T failed, with tendons being cut through by the sutures, whereas the other 2 specimens in group S and 4 specimens in group T failed due to suture breakage. CONCLUSIONS: Using high-tensile strength tapes in subpectoral biceps tenodesis using a suture anchor leads to significantly greater ultimate failure load as compared with using high-tensile strength sutures in a porcine model. Although lower levels of stiffness were found in high-tensile strength tape group, the difference in the means were not large between 2 groups. CLINICAL RELEVANCE: A strong suture–tendon structure may prevent clinical failure of a subpectoral biceps tenodesis using a suture anchor. |
format | Online Article Text |
id | pubmed-7754602 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-77546022020-12-28 High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model Hong, Chih-Kai Su, Wei-Ren Kuan, Fa-Chuan Chen, Yueh Chiang, Chen-Hao Hsu, Kai-Lan Arthrosc Sports Med Rehabil Original Article PURPOSE: To compare the biomechanical properties of high-tensile strength tape and a high-tensile strength suture in subpectoral biceps tenodesis using a suture anchor in a porcine tendon model. METHODS: A total of 24 artificial composite (polymer and glass fiber) humeri and porcine flexor profundus tendons were used. Two types of suture materials, high-tensile strength sutures (group S) and high-tensile strength tapes (group T), were evaluated. After we inserted metallic suture anchors with either 2 sutures or tapes 5 cm from the superomedial corner of the greater tuberosity, a Krackow suture technique was used to secure the tendons. After a preload of 5 N for 2 minutes, a cyclic loading test from 5 to 70 N was conducted for 500 cycles. Finally, the specimen was loaded to failure at a rate of 1 mm/s. RESULTS: There were no significant between-group differences in elongation after cyclic loading and elongation at failure load for group S and group T (P = .977 and .630, respectively). The ultimate failure loads in group T (278.2 ± 54 N) were significantly greater than those in group S (249.4 ± 32 N) (P = .028). In contrast, the stiffness values in group T (28.5 ± 4.0 N/mm) were significantly lower than those in group S (32.3 ± 4.5 N) (P = .028). Ten specimens in group S and 8 specimens in group T failed, with tendons being cut through by the sutures, whereas the other 2 specimens in group S and 4 specimens in group T failed due to suture breakage. CONCLUSIONS: Using high-tensile strength tapes in subpectoral biceps tenodesis using a suture anchor leads to significantly greater ultimate failure load as compared with using high-tensile strength sutures in a porcine model. Although lower levels of stiffness were found in high-tensile strength tape group, the difference in the means were not large between 2 groups. CLINICAL RELEVANCE: A strong suture–tendon structure may prevent clinical failure of a subpectoral biceps tenodesis using a suture anchor. Elsevier 2020-10-15 /pmc/articles/PMC7754602/ /pubmed/33376994 http://dx.doi.org/10.1016/j.asmr.2020.07.018 Text en © 2020 Published by Elsevier on behalf of the Arthroscopy Association of North America. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Hong, Chih-Kai Su, Wei-Ren Kuan, Fa-Chuan Chen, Yueh Chiang, Chen-Hao Hsu, Kai-Lan High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model |
title | High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model |
title_full | High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model |
title_fullStr | High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model |
title_full_unstemmed | High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model |
title_short | High-Tensile Strength Tapes Show Greater Ultimate Failure Load and Less Stiffness Than High-Tensile Strength Sutures in a Subpectoral Biceps Tenodesis Porcine Model |
title_sort | high-tensile strength tapes show greater ultimate failure load and less stiffness than high-tensile strength sutures in a subpectoral biceps tenodesis porcine model |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7754602/ https://www.ncbi.nlm.nih.gov/pubmed/33376994 http://dx.doi.org/10.1016/j.asmr.2020.07.018 |
work_keys_str_mv | AT hongchihkai hightensilestrengthtapesshowgreaterultimatefailureloadandlessstiffnessthanhightensilestrengthsuturesinasubpectoralbicepstenodesisporcinemodel AT suweiren hightensilestrengthtapesshowgreaterultimatefailureloadandlessstiffnessthanhightensilestrengthsuturesinasubpectoralbicepstenodesisporcinemodel AT kuanfachuan hightensilestrengthtapesshowgreaterultimatefailureloadandlessstiffnessthanhightensilestrengthsuturesinasubpectoralbicepstenodesisporcinemodel AT chenyueh hightensilestrengthtapesshowgreaterultimatefailureloadandlessstiffnessthanhightensilestrengthsuturesinasubpectoralbicepstenodesisporcinemodel AT chiangchenhao hightensilestrengthtapesshowgreaterultimatefailureloadandlessstiffnessthanhightensilestrengthsuturesinasubpectoralbicepstenodesisporcinemodel AT hsukailan hightensilestrengthtapesshowgreaterultimatefailureloadandlessstiffnessthanhightensilestrengthsuturesinasubpectoralbicepstenodesisporcinemodel |