Cargando…

Inclusion of the Acetabular Labrum Reduces Simulated Range of Motion of the Hip Compared With Bone Contact Models

PURPOSE: To determine whether inclusion of the acetabular labrum affects the maximum range of motion (ROM) during simulation of the flexion–adduction–internal rotation impingement examination. METHODS: Three-dimensional surface reconstructions of the femur, hemi-pelvis, and labrum from computed tomo...

Descripción completa

Detalles Bibliográficos
Autores principales: Atkins, Penny R., Hananouchi, Takehito, Anderson, Andrew E., Aoki, Stephen K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7754612/
https://www.ncbi.nlm.nih.gov/pubmed/33376992
http://dx.doi.org/10.1016/j.asmr.2020.07.014
_version_ 1783626230972547072
author Atkins, Penny R.
Hananouchi, Takehito
Anderson, Andrew E.
Aoki, Stephen K.
author_facet Atkins, Penny R.
Hananouchi, Takehito
Anderson, Andrew E.
Aoki, Stephen K.
author_sort Atkins, Penny R.
collection PubMed
description PURPOSE: To determine whether inclusion of the acetabular labrum affects the maximum range of motion (ROM) during simulation of the flexion–adduction–internal rotation impingement examination. METHODS: Three-dimensional surface reconstructions of the femur, hemi-pelvis, and labrum from computed tomography arthrography images of 19 participants were used to simulate maximum ROM during the flexion–adduction–internal rotation examination. Simulations were conducted for positions between 70° and 110° flexion and 0° and 20° adduction at 10° increments to measure maximum internal rotation and the position of contact between the femur and acetabular rim (bone-to-bone) or the femur and labrum (bone-to-labrum). Internal rotation angles and clock-face position values were compared between the 2 contact scenarios for each position. RESULTS: The ROM in the bone-to-labrum contact model was significantly less than that of the bone-to-bone contact model for all evaluated positions (P ≤ .001, except at 110° flexion and 20° adduction, P = .114). The inclusion of the labrum reduced internal rotation by a median [interquartile range] of 18 [15, 25]° while altering the position of contact on the acetabular clock-face by –0:01 [–0:27, 0:16]. The variability in contact location for the bone-to-labrum contact scenario was nearly double that of the bone-to-bone contact scenario, as indicated by the interquartile range. CONCLUSIONS: Inclusion of the anatomy of the acetabular labrum in collision models used to simulate impingement examinations reduced the internal rotation ROM by approximately 20° and increased variability in the location of contact relative to the acetabular rim. CLINICAL RELEVANCE: While standard bone-to-bone contact ROM simulations may be informative with respect to the relative change in ROM based on a surgical intervention (e.g., pre- and post-osteochondroplasty for cam-type femoroacetabular impingement), they may not accurately represent the clinical ROM of the joint or the kinematic position at which damage may occur due to shape mismatch between the femur and acetabulum.
format Online
Article
Text
id pubmed-7754612
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-77546122020-12-28 Inclusion of the Acetabular Labrum Reduces Simulated Range of Motion of the Hip Compared With Bone Contact Models Atkins, Penny R. Hananouchi, Takehito Anderson, Andrew E. Aoki, Stephen K. Arthrosc Sports Med Rehabil Original Article PURPOSE: To determine whether inclusion of the acetabular labrum affects the maximum range of motion (ROM) during simulation of the flexion–adduction–internal rotation impingement examination. METHODS: Three-dimensional surface reconstructions of the femur, hemi-pelvis, and labrum from computed tomography arthrography images of 19 participants were used to simulate maximum ROM during the flexion–adduction–internal rotation examination. Simulations were conducted for positions between 70° and 110° flexion and 0° and 20° adduction at 10° increments to measure maximum internal rotation and the position of contact between the femur and acetabular rim (bone-to-bone) or the femur and labrum (bone-to-labrum). Internal rotation angles and clock-face position values were compared between the 2 contact scenarios for each position. RESULTS: The ROM in the bone-to-labrum contact model was significantly less than that of the bone-to-bone contact model for all evaluated positions (P ≤ .001, except at 110° flexion and 20° adduction, P = .114). The inclusion of the labrum reduced internal rotation by a median [interquartile range] of 18 [15, 25]° while altering the position of contact on the acetabular clock-face by –0:01 [–0:27, 0:16]. The variability in contact location for the bone-to-labrum contact scenario was nearly double that of the bone-to-bone contact scenario, as indicated by the interquartile range. CONCLUSIONS: Inclusion of the anatomy of the acetabular labrum in collision models used to simulate impingement examinations reduced the internal rotation ROM by approximately 20° and increased variability in the location of contact relative to the acetabular rim. CLINICAL RELEVANCE: While standard bone-to-bone contact ROM simulations may be informative with respect to the relative change in ROM based on a surgical intervention (e.g., pre- and post-osteochondroplasty for cam-type femoroacetabular impingement), they may not accurately represent the clinical ROM of the joint or the kinematic position at which damage may occur due to shape mismatch between the femur and acetabulum. Elsevier 2020-10-06 /pmc/articles/PMC7754612/ /pubmed/33376992 http://dx.doi.org/10.1016/j.asmr.2020.07.014 Text en © 2020 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Atkins, Penny R.
Hananouchi, Takehito
Anderson, Andrew E.
Aoki, Stephen K.
Inclusion of the Acetabular Labrum Reduces Simulated Range of Motion of the Hip Compared With Bone Contact Models
title Inclusion of the Acetabular Labrum Reduces Simulated Range of Motion of the Hip Compared With Bone Contact Models
title_full Inclusion of the Acetabular Labrum Reduces Simulated Range of Motion of the Hip Compared With Bone Contact Models
title_fullStr Inclusion of the Acetabular Labrum Reduces Simulated Range of Motion of the Hip Compared With Bone Contact Models
title_full_unstemmed Inclusion of the Acetabular Labrum Reduces Simulated Range of Motion of the Hip Compared With Bone Contact Models
title_short Inclusion of the Acetabular Labrum Reduces Simulated Range of Motion of the Hip Compared With Bone Contact Models
title_sort inclusion of the acetabular labrum reduces simulated range of motion of the hip compared with bone contact models
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7754612/
https://www.ncbi.nlm.nih.gov/pubmed/33376992
http://dx.doi.org/10.1016/j.asmr.2020.07.014
work_keys_str_mv AT atkinspennyr inclusionoftheacetabularlabrumreducessimulatedrangeofmotionofthehipcomparedwithbonecontactmodels
AT hananouchitakehito inclusionoftheacetabularlabrumreducessimulatedrangeofmotionofthehipcomparedwithbonecontactmodels
AT andersonandrewe inclusionoftheacetabularlabrumreducessimulatedrangeofmotionofthehipcomparedwithbonecontactmodels
AT aokistephenk inclusionoftheacetabularlabrumreducessimulatedrangeofmotionofthehipcomparedwithbonecontactmodels