Cargando…

Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds

Determining the blood glucose level is important for the prevention and treatment of diabetes mellitus. We developed a sensor system using Quartz Crystal Microbalance (QCM) to determine the blood glucose level from human blood serum. This study consists of two experimental stages: artificial glucose...

Descripción completa

Detalles Bibliográficos
Autores principales: ŞAHİN SADIK, Evin, SARAOĞLU, Hamdi Melih, GÜROL, İlke, EBEOĞLU, Mehmet Ali, KOÇAK, Fatma Emel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Scientific and Technological Research Council of Turkey 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7754727/
https://www.ncbi.nlm.nih.gov/pubmed/33488230
http://dx.doi.org/10.3906/kim-1911-69
_version_ 1783626249761980416
author ŞAHİN SADIK, Evin
SARAOĞLU, Hamdi Melih
GÜROL, İlke
EBEOĞLU, Mehmet Ali
KOÇAK, Fatma Emel
author_facet ŞAHİN SADIK, Evin
SARAOĞLU, Hamdi Melih
GÜROL, İlke
EBEOĞLU, Mehmet Ali
KOÇAK, Fatma Emel
author_sort ŞAHİN SADIK, Evin
collection PubMed
description Determining the blood glucose level is important for the prevention and treatment of diabetes mellitus. We developed a sensor system using Quartz Crystal Microbalance (QCM) to determine the blood glucose level from human blood serum. This study consists of two experimental stages: artificial glucose/pure water solution tests and human blood serum tests. In the first stage of the study, the QCM sensor with the highest performance was identified using artificial glucose solution concentrations. In the second stage of the study, human blood serum measurements were performed using QCM to determine blood glucose levels. QCM sensors were coated with phthalocyanines (Pcs) by jet spray method. The blood glucose values of 96 volunteers, which ranged from 71 mg/dL to 329 mg/dL, were recorded. As a result of the study, human glucose values were determined with an average error of 3.25%.
format Online
Article
Text
id pubmed-7754727
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Scientific and Technological Research Council of Turkey
record_format MEDLINE/PubMed
spelling pubmed-77547272021-01-22 Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds ŞAHİN SADIK, Evin SARAOĞLU, Hamdi Melih GÜROL, İlke EBEOĞLU, Mehmet Ali KOÇAK, Fatma Emel Turk J Chem Article Determining the blood glucose level is important for the prevention and treatment of diabetes mellitus. We developed a sensor system using Quartz Crystal Microbalance (QCM) to determine the blood glucose level from human blood serum. This study consists of two experimental stages: artificial glucose/pure water solution tests and human blood serum tests. In the first stage of the study, the QCM sensor with the highest performance was identified using artificial glucose solution concentrations. In the second stage of the study, human blood serum measurements were performed using QCM to determine blood glucose levels. QCM sensors were coated with phthalocyanines (Pcs) by jet spray method. The blood glucose values of 96 volunteers, which ranged from 71 mg/dL to 329 mg/dL, were recorded. As a result of the study, human glucose values were determined with an average error of 3.25%. The Scientific and Technological Research Council of Turkey 2020-10-26 /pmc/articles/PMC7754727/ /pubmed/33488230 http://dx.doi.org/10.3906/kim-1911-69 Text en Copyright © 2020 The Author(s) This article is distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/4.0/ ), which permits unrestricted use and redistribution provided that the original author and source are credited.
spellingShingle Article
ŞAHİN SADIK, Evin
SARAOĞLU, Hamdi Melih
GÜROL, İlke
EBEOĞLU, Mehmet Ali
KOÇAK, Fatma Emel
Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds
title Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds
title_full Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds
title_fullStr Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds
title_full_unstemmed Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds
title_short Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds
title_sort determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7754727/
https://www.ncbi.nlm.nih.gov/pubmed/33488230
http://dx.doi.org/10.3906/kim-1911-69
work_keys_str_mv AT sahinsadikevin determinationofbloodglucoseparameterfromhumanbloodserumbyusingaquartzcrystalmicrobalancesensorcoatedwithphthalocyaninescompounds
AT saraogluhamdimelih determinationofbloodglucoseparameterfromhumanbloodserumbyusingaquartzcrystalmicrobalancesensorcoatedwithphthalocyaninescompounds
AT gurolilke determinationofbloodglucoseparameterfromhumanbloodserumbyusingaquartzcrystalmicrobalancesensorcoatedwithphthalocyaninescompounds
AT ebeoglumehmetali determinationofbloodglucoseparameterfromhumanbloodserumbyusingaquartzcrystalmicrobalancesensorcoatedwithphthalocyaninescompounds
AT kocakfatmaemel determinationofbloodglucoseparameterfromhumanbloodserumbyusingaquartzcrystalmicrobalancesensorcoatedwithphthalocyaninescompounds