Cargando…
Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds
Determining the blood glucose level is important for the prevention and treatment of diabetes mellitus. We developed a sensor system using Quartz Crystal Microbalance (QCM) to determine the blood glucose level from human blood serum. This study consists of two experimental stages: artificial glucose...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Scientific and Technological Research Council of Turkey
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7754727/ https://www.ncbi.nlm.nih.gov/pubmed/33488230 http://dx.doi.org/10.3906/kim-1911-69 |
_version_ | 1783626249761980416 |
---|---|
author | ŞAHİN SADIK, Evin SARAOĞLU, Hamdi Melih GÜROL, İlke EBEOĞLU, Mehmet Ali KOÇAK, Fatma Emel |
author_facet | ŞAHİN SADIK, Evin SARAOĞLU, Hamdi Melih GÜROL, İlke EBEOĞLU, Mehmet Ali KOÇAK, Fatma Emel |
author_sort | ŞAHİN SADIK, Evin |
collection | PubMed |
description | Determining the blood glucose level is important for the prevention and treatment of diabetes mellitus. We developed a sensor system using Quartz Crystal Microbalance (QCM) to determine the blood glucose level from human blood serum. This study consists of two experimental stages: artificial glucose/pure water solution tests and human blood serum tests. In the first stage of the study, the QCM sensor with the highest performance was identified using artificial glucose solution concentrations. In the second stage of the study, human blood serum measurements were performed using QCM to determine blood glucose levels. QCM sensors were coated with phthalocyanines (Pcs) by jet spray method. The blood glucose values of 96 volunteers, which ranged from 71 mg/dL to 329 mg/dL, were recorded. As a result of the study, human glucose values were determined with an average error of 3.25%. |
format | Online Article Text |
id | pubmed-7754727 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | The Scientific and Technological Research Council of Turkey |
record_format | MEDLINE/PubMed |
spelling | pubmed-77547272021-01-22 Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds ŞAHİN SADIK, Evin SARAOĞLU, Hamdi Melih GÜROL, İlke EBEOĞLU, Mehmet Ali KOÇAK, Fatma Emel Turk J Chem Article Determining the blood glucose level is important for the prevention and treatment of diabetes mellitus. We developed a sensor system using Quartz Crystal Microbalance (QCM) to determine the blood glucose level from human blood serum. This study consists of two experimental stages: artificial glucose/pure water solution tests and human blood serum tests. In the first stage of the study, the QCM sensor with the highest performance was identified using artificial glucose solution concentrations. In the second stage of the study, human blood serum measurements were performed using QCM to determine blood glucose levels. QCM sensors were coated with phthalocyanines (Pcs) by jet spray method. The blood glucose values of 96 volunteers, which ranged from 71 mg/dL to 329 mg/dL, were recorded. As a result of the study, human glucose values were determined with an average error of 3.25%. The Scientific and Technological Research Council of Turkey 2020-10-26 /pmc/articles/PMC7754727/ /pubmed/33488230 http://dx.doi.org/10.3906/kim-1911-69 Text en Copyright © 2020 The Author(s) This article is distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/4.0/ ), which permits unrestricted use and redistribution provided that the original author and source are credited. |
spellingShingle | Article ŞAHİN SADIK, Evin SARAOĞLU, Hamdi Melih GÜROL, İlke EBEOĞLU, Mehmet Ali KOÇAK, Fatma Emel Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds |
title | Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds |
title_full | Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds |
title_fullStr | Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds |
title_full_unstemmed | Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds |
title_short | Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds |
title_sort | determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7754727/ https://www.ncbi.nlm.nih.gov/pubmed/33488230 http://dx.doi.org/10.3906/kim-1911-69 |
work_keys_str_mv | AT sahinsadikevin determinationofbloodglucoseparameterfromhumanbloodserumbyusingaquartzcrystalmicrobalancesensorcoatedwithphthalocyaninescompounds AT saraogluhamdimelih determinationofbloodglucoseparameterfromhumanbloodserumbyusingaquartzcrystalmicrobalancesensorcoatedwithphthalocyaninescompounds AT gurolilke determinationofbloodglucoseparameterfromhumanbloodserumbyusingaquartzcrystalmicrobalancesensorcoatedwithphthalocyaninescompounds AT ebeoglumehmetali determinationofbloodglucoseparameterfromhumanbloodserumbyusingaquartzcrystalmicrobalancesensorcoatedwithphthalocyaninescompounds AT kocakfatmaemel determinationofbloodglucoseparameterfromhumanbloodserumbyusingaquartzcrystalmicrobalancesensorcoatedwithphthalocyaninescompounds |