Cargando…
Difference in Pain and Discomfort of Comparable Wrist Movements Induced by Magnetic or Electrical Stimulation for Peripheral Nerves in the Dorsal Forearm
PURPOSE: Both repetitive peripheral magnetic stimulation (rPMS) and transcutaneous electrical current stimulation (TES) could elicit the limb movements; it is still unclear how subjective sensation is changed according to the amount of limb movements. We investigated the pain and discomfort induced...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7755354/ https://www.ncbi.nlm.nih.gov/pubmed/33376417 http://dx.doi.org/10.2147/MDER.S271258 |
_version_ | 1783626337181761536 |
---|---|
author | Abe, Genji Oyama, Hideki Liao, Zhenyi Honda, Keita Yashima, Kenji Asao, Akihiko Izumi, Shin-Ichi |
author_facet | Abe, Genji Oyama, Hideki Liao, Zhenyi Honda, Keita Yashima, Kenji Asao, Akihiko Izumi, Shin-Ichi |
author_sort | Abe, Genji |
collection | PubMed |
description | PURPOSE: Both repetitive peripheral magnetic stimulation (rPMS) and transcutaneous electrical current stimulation (TES) could elicit the limb movements; it is still unclear how subjective sensation is changed according to the amount of limb movements. We investigated the pain and discomfort induced by newly developed rPMS and TES of peripheral nerves in the dorsal forearm. METHODS: The subjects were 12 healthy adults. The stimulus site was the right dorsal forearm; thus, when stimulated, wrist dorsiflexion was induced. The rPMS was delivered by the new stimulator, Pathleader at 10 stimulus intensity levels, and TES intensity was in 1-mA increments. The duration of each stimulation was 2 s. The analysis parameters were subjective pain and discomfort, measured by a numerical rating scale. The rating scale at corresponding levels of integrated range of movement (iROM) induced by rPMS or TES was compared. The subjective values were analyzed by two-way repeated measures ANOVA with the stimulus conditions (rPMS, TES) and the seven levels of iROM (20–140 ºs). RESULTS: In the rPMS experiments, stimuli were administered to all subjects at all stimulus intensities. In the TES experiments, none of the subjects dropped out between 1 and 16 mA, but there were dropouts at each of the intensities as follows: 1 subject at 17 mA, 20 mA, 22 mA, 23 mA, 27 mA, 29 mA and 2 subjects at 21 mA, 24 mA, 26 mA. The main effects of the stimulus conditions and iROM were significant for pain and discomfort. Post hoc analysis demonstrated that pain and discomfort in rPMS were significantly lower compared to TES when the iROM was above 60 ºs and 80 ºs, respectively. CONCLUSION: New rPMS stimulator, Pathleader, caused less pain and discomfort than TES, but this was only evident when comparatively large joint movements occurred. |
format | Online Article Text |
id | pubmed-7755354 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-77553542020-12-28 Difference in Pain and Discomfort of Comparable Wrist Movements Induced by Magnetic or Electrical Stimulation for Peripheral Nerves in the Dorsal Forearm Abe, Genji Oyama, Hideki Liao, Zhenyi Honda, Keita Yashima, Kenji Asao, Akihiko Izumi, Shin-Ichi Med Devices (Auckl) Original Research PURPOSE: Both repetitive peripheral magnetic stimulation (rPMS) and transcutaneous electrical current stimulation (TES) could elicit the limb movements; it is still unclear how subjective sensation is changed according to the amount of limb movements. We investigated the pain and discomfort induced by newly developed rPMS and TES of peripheral nerves in the dorsal forearm. METHODS: The subjects were 12 healthy adults. The stimulus site was the right dorsal forearm; thus, when stimulated, wrist dorsiflexion was induced. The rPMS was delivered by the new stimulator, Pathleader at 10 stimulus intensity levels, and TES intensity was in 1-mA increments. The duration of each stimulation was 2 s. The analysis parameters were subjective pain and discomfort, measured by a numerical rating scale. The rating scale at corresponding levels of integrated range of movement (iROM) induced by rPMS or TES was compared. The subjective values were analyzed by two-way repeated measures ANOVA with the stimulus conditions (rPMS, TES) and the seven levels of iROM (20–140 ºs). RESULTS: In the rPMS experiments, stimuli were administered to all subjects at all stimulus intensities. In the TES experiments, none of the subjects dropped out between 1 and 16 mA, but there were dropouts at each of the intensities as follows: 1 subject at 17 mA, 20 mA, 22 mA, 23 mA, 27 mA, 29 mA and 2 subjects at 21 mA, 24 mA, 26 mA. The main effects of the stimulus conditions and iROM were significant for pain and discomfort. Post hoc analysis demonstrated that pain and discomfort in rPMS were significantly lower compared to TES when the iROM was above 60 ºs and 80 ºs, respectively. CONCLUSION: New rPMS stimulator, Pathleader, caused less pain and discomfort than TES, but this was only evident when comparatively large joint movements occurred. Dove 2020-12-18 /pmc/articles/PMC7755354/ /pubmed/33376417 http://dx.doi.org/10.2147/MDER.S271258 Text en © 2020 Abe et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Abe, Genji Oyama, Hideki Liao, Zhenyi Honda, Keita Yashima, Kenji Asao, Akihiko Izumi, Shin-Ichi Difference in Pain and Discomfort of Comparable Wrist Movements Induced by Magnetic or Electrical Stimulation for Peripheral Nerves in the Dorsal Forearm |
title | Difference in Pain and Discomfort of Comparable Wrist Movements Induced by Magnetic or Electrical Stimulation for Peripheral Nerves in the Dorsal Forearm |
title_full | Difference in Pain and Discomfort of Comparable Wrist Movements Induced by Magnetic or Electrical Stimulation for Peripheral Nerves in the Dorsal Forearm |
title_fullStr | Difference in Pain and Discomfort of Comparable Wrist Movements Induced by Magnetic or Electrical Stimulation for Peripheral Nerves in the Dorsal Forearm |
title_full_unstemmed | Difference in Pain and Discomfort of Comparable Wrist Movements Induced by Magnetic or Electrical Stimulation for Peripheral Nerves in the Dorsal Forearm |
title_short | Difference in Pain and Discomfort of Comparable Wrist Movements Induced by Magnetic or Electrical Stimulation for Peripheral Nerves in the Dorsal Forearm |
title_sort | difference in pain and discomfort of comparable wrist movements induced by magnetic or electrical stimulation for peripheral nerves in the dorsal forearm |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7755354/ https://www.ncbi.nlm.nih.gov/pubmed/33376417 http://dx.doi.org/10.2147/MDER.S271258 |
work_keys_str_mv | AT abegenji differenceinpainanddiscomfortofcomparablewristmovementsinducedbymagneticorelectricalstimulationforperipheralnervesinthedorsalforearm AT oyamahideki differenceinpainanddiscomfortofcomparablewristmovementsinducedbymagneticorelectricalstimulationforperipheralnervesinthedorsalforearm AT liaozhenyi differenceinpainanddiscomfortofcomparablewristmovementsinducedbymagneticorelectricalstimulationforperipheralnervesinthedorsalforearm AT hondakeita differenceinpainanddiscomfortofcomparablewristmovementsinducedbymagneticorelectricalstimulationforperipheralnervesinthedorsalforearm AT yashimakenji differenceinpainanddiscomfortofcomparablewristmovementsinducedbymagneticorelectricalstimulationforperipheralnervesinthedorsalforearm AT asaoakihiko differenceinpainanddiscomfortofcomparablewristmovementsinducedbymagneticorelectricalstimulationforperipheralnervesinthedorsalforearm AT izumishinichi differenceinpainanddiscomfortofcomparablewristmovementsinducedbymagneticorelectricalstimulationforperipheralnervesinthedorsalforearm |