Cargando…
Collecting e‐cigarette aerosols for in vitro applications: A survey of the biomedical literature and opportunities to increase the value of submerged cell culture‐based assessments
Electronic nicotine delivery systems (ENDS) are being developed as potentially reduced‐risk alternatives to the continued use of combustible tobacco products. Because of the widespread uptake of ENDS—in particular, e‐cigarettes—the biological effects, including the toxic potential, of their aerosols...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7756347/ https://www.ncbi.nlm.nih.gov/pubmed/33015847 http://dx.doi.org/10.1002/jat.4064 |
_version_ | 1783626521204752384 |
---|---|
author | Smart, Daniel J. Phillips, Gary |
author_facet | Smart, Daniel J. Phillips, Gary |
author_sort | Smart, Daniel J. |
collection | PubMed |
description | Electronic nicotine delivery systems (ENDS) are being developed as potentially reduced‐risk alternatives to the continued use of combustible tobacco products. Because of the widespread uptake of ENDS—in particular, e‐cigarettes—the biological effects, including the toxic potential, of their aerosols are under investigation. Preclinically, collection of such aerosols is a prerequisite for testing in submerged cell culture‐based in vitro assays; however, despite the growth in this research area, there is no apparent standardized collection method for this application. To this end, through an Institute for in vitro Sciences, Inc. workshop initiative, we surveyed the biomedical literature catalogued in PubMed® to map the types of methods hitherto used and reported publicly. From the 47 relevant publications retrieved, we identified seven distinct collection methods. Bubble‐through (with aqueous solvents) and Cambridge filter pad (CFP) (with polar solvents) collection were the most frequently cited methods (57% and 18%, respectively), while the five others (CFP + bubble‐through; condensation; cotton filters; settle‐upon; settle‐upon + dry) were cited less often (2–10%). Critically, the collected aerosol fractions were generally found to be only minimally characterized chemically, if at all. Furthermore, there was large heterogeneity among other experimental parameters (e.g., vaping regimen). Consequently, we recommend that more comprehensive research be conducted to identify the method(s) that produce the fraction(s) most representative of the native aerosol. We also endorse standardization of the aerosol generation process. These should be regarded as opportunities for increasing the value of in vitro assessments in relation to predicting effects on human health. |
format | Online Article Text |
id | pubmed-7756347 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-77563472020-12-28 Collecting e‐cigarette aerosols for in vitro applications: A survey of the biomedical literature and opportunities to increase the value of submerged cell culture‐based assessments Smart, Daniel J. Phillips, Gary J Appl Toxicol Review Articles Electronic nicotine delivery systems (ENDS) are being developed as potentially reduced‐risk alternatives to the continued use of combustible tobacco products. Because of the widespread uptake of ENDS—in particular, e‐cigarettes—the biological effects, including the toxic potential, of their aerosols are under investigation. Preclinically, collection of such aerosols is a prerequisite for testing in submerged cell culture‐based in vitro assays; however, despite the growth in this research area, there is no apparent standardized collection method for this application. To this end, through an Institute for in vitro Sciences, Inc. workshop initiative, we surveyed the biomedical literature catalogued in PubMed® to map the types of methods hitherto used and reported publicly. From the 47 relevant publications retrieved, we identified seven distinct collection methods. Bubble‐through (with aqueous solvents) and Cambridge filter pad (CFP) (with polar solvents) collection were the most frequently cited methods (57% and 18%, respectively), while the five others (CFP + bubble‐through; condensation; cotton filters; settle‐upon; settle‐upon + dry) were cited less often (2–10%). Critically, the collected aerosol fractions were generally found to be only minimally characterized chemically, if at all. Furthermore, there was large heterogeneity among other experimental parameters (e.g., vaping regimen). Consequently, we recommend that more comprehensive research be conducted to identify the method(s) that produce the fraction(s) most representative of the native aerosol. We also endorse standardization of the aerosol generation process. These should be regarded as opportunities for increasing the value of in vitro assessments in relation to predicting effects on human health. John Wiley and Sons Inc. 2020-10-04 2021-01 /pmc/articles/PMC7756347/ /pubmed/33015847 http://dx.doi.org/10.1002/jat.4064 Text en © 2020 The Authors. Journal of Applied Toxicology published by John Wiley & Sons Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Articles Smart, Daniel J. Phillips, Gary Collecting e‐cigarette aerosols for in vitro applications: A survey of the biomedical literature and opportunities to increase the value of submerged cell culture‐based assessments |
title | Collecting e‐cigarette aerosols for in vitro applications: A survey of the biomedical literature and opportunities to increase the value of submerged cell culture‐based assessments |
title_full | Collecting e‐cigarette aerosols for in vitro applications: A survey of the biomedical literature and opportunities to increase the value of submerged cell culture‐based assessments |
title_fullStr | Collecting e‐cigarette aerosols for in vitro applications: A survey of the biomedical literature and opportunities to increase the value of submerged cell culture‐based assessments |
title_full_unstemmed | Collecting e‐cigarette aerosols for in vitro applications: A survey of the biomedical literature and opportunities to increase the value of submerged cell culture‐based assessments |
title_short | Collecting e‐cigarette aerosols for in vitro applications: A survey of the biomedical literature and opportunities to increase the value of submerged cell culture‐based assessments |
title_sort | collecting e‐cigarette aerosols for in vitro applications: a survey of the biomedical literature and opportunities to increase the value of submerged cell culture‐based assessments |
topic | Review Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7756347/ https://www.ncbi.nlm.nih.gov/pubmed/33015847 http://dx.doi.org/10.1002/jat.4064 |
work_keys_str_mv | AT smartdanielj collectingecigaretteaerosolsforinvitroapplicationsasurveyofthebiomedicalliteratureandopportunitiestoincreasethevalueofsubmergedcellculturebasedassessments AT phillipsgary collectingecigaretteaerosolsforinvitroapplicationsasurveyofthebiomedicalliteratureandopportunitiestoincreasethevalueofsubmergedcellculturebasedassessments |