Cargando…

Percutaneous Closure of Ventricular Septal Defects in 116 Patients: Experience with different devices

OBJECTIVES: This study aimed to review the experience with percutaneous closure of ventricular septal defects (VSDs) at the National Heart Center (NHC) in Muscat, Oman. METHODS: This retrospective study was conducted from November 2008 to December 2017. Patients’ electronic medical records were revi...

Descripción completa

Detalles Bibliográficos
Autores principales: Al Senaidi, Khalfan S., Al Maskary, Salim, Thomas, Eapen, Dimitrov, Boris, Al Farqani, Abdullah
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sultan Qaboos University Medical Journal, College of Medicine & Health Sciences 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7757938/
https://www.ncbi.nlm.nih.gov/pubmed/33414941
http://dx.doi.org/10.18295/squmj.2020.20.04.012
Descripción
Sumario:OBJECTIVES: This study aimed to review the experience with percutaneous closure of ventricular septal defects (VSDs) at the National Heart Center (NHC) in Muscat, Oman. METHODS: This retrospective study was conducted from November 2008 to December 2017. Patients’ electronic medical records were reviewed to identify their clinical, imaging and interventional data before and after the procedure and on the last follow-up. RESULTS: A total of 116 patients, the majority of which were female (58%), underwent 118 percutaneous procedures for VSD closure at a median age of 3.54 years (range: 0.25–33 years) and a median weight of 12 kg (range: 3.5–78 kg). The mean diameter of the VSDs as determined by transoesophageal echocardiogram was 5.6 ± 1.9 mm (n = 105). The commonest type of VSD was perimembranous (n = 75, 63.5%). Devices were successfully placed during 111 (94.1%) procedures in 109 (94.0%) patients, with the commonest device being a Amplatzer™ duct occluder I (St. Jude Medical, Little Canada, Minnesota, USA; n = 39, 35.1%). There was no mortality. Early major cardiac complications occurred in six patients (5.5%) with device embolisation being the commonest (n = 4, 3.7%). The median follow-up period was 19 months (range: 1–84 months) in 89 (81.7%) of the patients. One patient (0.9%) required a permanent pacemaker for a complete heart block. CONCLUSION: This study has demonstrated a good rate of VSD closure with low morbidity and no mortality using the percutaneous approach with different devices. Long-term follow-up is needed to specifically evaluate the function of adjacent structures and the long-term effects on conduction systems.