Cargando…

Incorporating Antimicrobial Nanomaterial and its Effect on the Antimicrobial Activity, Flow and Radiopacity of Endodontic Sealers

OBJECTIVE: This preliminary study aimed to evaluate the antimicrobial activity, flow and radiopacity of endodontic sealers with nanostructured silver vanadate decorated with silver nanoparticles (AgVO3). METHODS: The minimum inhibitory concentration (MIC) of AgVO3 was evaluated against Enterococcus...

Descripción completa

Detalles Bibliográficos
Autores principales: Teixeira, Ana Beatriz Vilela, Vidal, Carla Larissa, de Castro, Denise Tornavoi, de Oliveira-Santos, Christiano, Schiavon, Marco Antônio, dos Reis, Andréa Cândido
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kare Publishing 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7757947/
https://www.ncbi.nlm.nih.gov/pubmed/33403330
http://dx.doi.org/10.14744/eej.2017.16029
_version_ 1783626833317593088
author Teixeira, Ana Beatriz Vilela
Vidal, Carla Larissa
de Castro, Denise Tornavoi
de Oliveira-Santos, Christiano
Schiavon, Marco Antônio
dos Reis, Andréa Cândido
author_facet Teixeira, Ana Beatriz Vilela
Vidal, Carla Larissa
de Castro, Denise Tornavoi
de Oliveira-Santos, Christiano
Schiavon, Marco Antônio
dos Reis, Andréa Cândido
author_sort Teixeira, Ana Beatriz Vilela
collection PubMed
description OBJECTIVE: This preliminary study aimed to evaluate the antimicrobial activity, flow and radiopacity of endodontic sealers with nanostructured silver vanadate decorated with silver nanoparticles (AgVO3). METHODS: The minimum inhibitory concentration (MIC) of AgVO3 was evaluated against Enterococcus faecalis, Pseudomonas aeruginosa and Escherichia coli. Specimens were prepared from the following endodontic sealers: AH Plus (DENTSPLY DeTrey GmbH, Konstanz, Germany), Sealapex (Sybron Endo, Orange, CA, USA), Sealer 26 (DENTSPLY, Petrópolis, Brazil) and Endofill (DENTSPLY, Petrópolis, Brazil), with concentrations of 0%, 2.5%, 5% and 10% of AgVO3. Agar diffusion was used to evaluate the materials after 48 hours and 7 days (n=6). Flow (n=6) and radiopacity (n=9) were evaluated. The data were analysed by analysis of variance (ANOVA) and the Tukey honestly significant difference (HSD) (α=0.05). RESULTS: The MIC of AgVO3 was 500 μg/mL for E. faecalis and 31.25 μg/mL for P. aeruginosa and E. coli. The AgVO3 did not influence the antimicrobial activity of AH Plus against E. faecalis (P>0.05) but did promote this activity for Sealapex (P<0.01). Moreover, this activity increased for Endofill from 2.5% and for Sealer 26 from 5% (P<0.05). Against P. aeruginosa, only AH Plus and Endofill 10% inhibited zone formation (P<0.01). The antimicrobial activity of Endofill increased from 2.5% against E. coli (P<0.01). Sealapex 5% and 10% (P<0.01), Sealer 26 10% and AH Plus promoted antimicrobial activity against E. coli. An increase in the zone of inhibition occurred between 48 hours and 7 days in the Sealapex 10% and Endofill 5% groups against E. coli. The flow of AH Plus and Endofill decreased with the increase of AgVO3 (P<0.05), and the flow of Sealer 26 and Sealapex was not affected (P>0.05). The radiopacity of AH Plus increased with AgVO3 (P<0.05). Endofill 5% and 10% did not differ from the control Endofill (P>0.05). The incorporation of AgVO3 did not influence the radiopacity of Sealer 26 (P>0.05). The incorporation of 2.5% and 5% AgVO3 reduced the radiopacity of Sealapex (P<0.05). CONCLUSION: Adding AgVO3 may increase the antimicrobial effect of endodontic sealers without major changes in their physicochemical properties.
format Online
Article
Text
id pubmed-7757947
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Kare Publishing
record_format MEDLINE/PubMed
spelling pubmed-77579472021-01-04 Incorporating Antimicrobial Nanomaterial and its Effect on the Antimicrobial Activity, Flow and Radiopacity of Endodontic Sealers Teixeira, Ana Beatriz Vilela Vidal, Carla Larissa de Castro, Denise Tornavoi de Oliveira-Santos, Christiano Schiavon, Marco Antônio dos Reis, Andréa Cândido Eur Endod J Original Article OBJECTIVE: This preliminary study aimed to evaluate the antimicrobial activity, flow and radiopacity of endodontic sealers with nanostructured silver vanadate decorated with silver nanoparticles (AgVO3). METHODS: The minimum inhibitory concentration (MIC) of AgVO3 was evaluated against Enterococcus faecalis, Pseudomonas aeruginosa and Escherichia coli. Specimens were prepared from the following endodontic sealers: AH Plus (DENTSPLY DeTrey GmbH, Konstanz, Germany), Sealapex (Sybron Endo, Orange, CA, USA), Sealer 26 (DENTSPLY, Petrópolis, Brazil) and Endofill (DENTSPLY, Petrópolis, Brazil), with concentrations of 0%, 2.5%, 5% and 10% of AgVO3. Agar diffusion was used to evaluate the materials after 48 hours and 7 days (n=6). Flow (n=6) and radiopacity (n=9) were evaluated. The data were analysed by analysis of variance (ANOVA) and the Tukey honestly significant difference (HSD) (α=0.05). RESULTS: The MIC of AgVO3 was 500 μg/mL for E. faecalis and 31.25 μg/mL for P. aeruginosa and E. coli. The AgVO3 did not influence the antimicrobial activity of AH Plus against E. faecalis (P>0.05) but did promote this activity for Sealapex (P<0.01). Moreover, this activity increased for Endofill from 2.5% and for Sealer 26 from 5% (P<0.05). Against P. aeruginosa, only AH Plus and Endofill 10% inhibited zone formation (P<0.01). The antimicrobial activity of Endofill increased from 2.5% against E. coli (P<0.01). Sealapex 5% and 10% (P<0.01), Sealer 26 10% and AH Plus promoted antimicrobial activity against E. coli. An increase in the zone of inhibition occurred between 48 hours and 7 days in the Sealapex 10% and Endofill 5% groups against E. coli. The flow of AH Plus and Endofill decreased with the increase of AgVO3 (P<0.05), and the flow of Sealer 26 and Sealapex was not affected (P>0.05). The radiopacity of AH Plus increased with AgVO3 (P<0.05). Endofill 5% and 10% did not differ from the control Endofill (P>0.05). The incorporation of AgVO3 did not influence the radiopacity of Sealer 26 (P>0.05). The incorporation of 2.5% and 5% AgVO3 reduced the radiopacity of Sealapex (P<0.05). CONCLUSION: Adding AgVO3 may increase the antimicrobial effect of endodontic sealers without major changes in their physicochemical properties. Kare Publishing 2017-07-06 /pmc/articles/PMC7757947/ /pubmed/33403330 http://dx.doi.org/10.14744/eej.2017.16029 Text en Copyright: © 2020 European Endodontic Journal http://creativecommons.org/licenses/by-nc/4.0 This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License
spellingShingle Original Article
Teixeira, Ana Beatriz Vilela
Vidal, Carla Larissa
de Castro, Denise Tornavoi
de Oliveira-Santos, Christiano
Schiavon, Marco Antônio
dos Reis, Andréa Cândido
Incorporating Antimicrobial Nanomaterial and its Effect on the Antimicrobial Activity, Flow and Radiopacity of Endodontic Sealers
title Incorporating Antimicrobial Nanomaterial and its Effect on the Antimicrobial Activity, Flow and Radiopacity of Endodontic Sealers
title_full Incorporating Antimicrobial Nanomaterial and its Effect on the Antimicrobial Activity, Flow and Radiopacity of Endodontic Sealers
title_fullStr Incorporating Antimicrobial Nanomaterial and its Effect on the Antimicrobial Activity, Flow and Radiopacity of Endodontic Sealers
title_full_unstemmed Incorporating Antimicrobial Nanomaterial and its Effect on the Antimicrobial Activity, Flow and Radiopacity of Endodontic Sealers
title_short Incorporating Antimicrobial Nanomaterial and its Effect on the Antimicrobial Activity, Flow and Radiopacity of Endodontic Sealers
title_sort incorporating antimicrobial nanomaterial and its effect on the antimicrobial activity, flow and radiopacity of endodontic sealers
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7757947/
https://www.ncbi.nlm.nih.gov/pubmed/33403330
http://dx.doi.org/10.14744/eej.2017.16029
work_keys_str_mv AT teixeiraanabeatrizvilela incorporatingantimicrobialnanomaterialanditseffectontheantimicrobialactivityflowandradiopacityofendodonticsealers
AT vidalcarlalarissa incorporatingantimicrobialnanomaterialanditseffectontheantimicrobialactivityflowandradiopacityofendodonticsealers
AT decastrodenisetornavoi incorporatingantimicrobialnanomaterialanditseffectontheantimicrobialactivityflowandradiopacityofendodonticsealers
AT deoliveirasantoschristiano incorporatingantimicrobialnanomaterialanditseffectontheantimicrobialactivityflowandradiopacityofendodonticsealers
AT schiavonmarcoantonio incorporatingantimicrobialnanomaterialanditseffectontheantimicrobialactivityflowandradiopacityofendodonticsealers
AT dosreisandreacandido incorporatingantimicrobialnanomaterialanditseffectontheantimicrobialactivityflowandradiopacityofendodonticsealers