Test-retest repeatability of ultrasonographic shear wave elastography in a rat liver fibrosis model: toward a quantitative biomarker for preclinical trials

PURPOSE: This study evaluated the test-retest repeatability and measurement variability of ultrasonographic shear wave elastography (SWE) for liver stiffness in a rat liver fibrosis model. METHODS: In 31 Sprague-Dawley rats divided into three groups (high-dose, low-dose, and control), liver fibrosis...

Descripción completa

Detalles Bibliográficos
Autores principales: Shin, Youngbin, Huh, Jimi, Ham, Su Jung, Cho, Young Chul, Choi, Yoonseok, Woo, Dong-Cheol, Lee, Jeongjin, Kim, Kyung Won
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Ultrasound in Medicine 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7758098/
https://www.ncbi.nlm.nih.gov/pubmed/32580267
http://dx.doi.org/10.14366/usg.19088
_version_ 1783626866266996736
author Shin, Youngbin
Huh, Jimi
Ham, Su Jung
Cho, Young Chul
Choi, Yoonseok
Woo, Dong-Cheol
Lee, Jeongjin
Kim, Kyung Won
author_facet Shin, Youngbin
Huh, Jimi
Ham, Su Jung
Cho, Young Chul
Choi, Yoonseok
Woo, Dong-Cheol
Lee, Jeongjin
Kim, Kyung Won
author_sort Shin, Youngbin
collection PubMed
description PURPOSE: This study evaluated the test-retest repeatability and measurement variability of ultrasonographic shear wave elastography (SWE) for liver stiffness in a rat liver fibrosis model. METHODS: In 31 Sprague-Dawley rats divided into three groups (high-dose, low-dose, and control), liver fibrosis was induced by intraperitoneal administration of thioacetamide for 8 weeks. A dedicated radiographer performed SWE to measure liver stiffness in kilopascals in two sessions at a 3-day interval. We calculated correlations between liver stiffness and histopathologic results, measurement variability in each session using coefficients of variation (CoVs) and interquartile/median (IQR/M), and test-retest repeatability between both sessions using the repeatability coefficient. RESULTS: Different levels of liver fibrosis in each group were successfully induced in the animal model. The mean liver stiffness values were 8.88±1.48 kPa in the control group, 11.62±1.70 kPa in the low-dose group, and 11.91±1.73 kPa in the high-dose group. The correlation between collagen areas and liver stiffness values was moderate (r=0.6). In all groups, the second session yielded lower CoVs (i.e., more reliable results) for liver stiffness than the first session, suggesting a training effect for the operator. The mean IQR/M values were also lower in the second session than in the first session, which had four outliers (0.21 vs. 0.12, P<0.001). The test-retest repeatability coefficient was 3.75 kPa and decreased to 2.82 kPa after removing the four outliers. CONCLUSION: The use of ultrasonographic SWE was confirmed to be feasible and repeatable for evaluating liver fibrosis in preclinical trials. Operator training might reduce variability in liver stiffness measurements.
format Online
Article
Text
id pubmed-7758098
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Society of Ultrasound in Medicine
record_format MEDLINE/PubMed
spelling pubmed-77580982021-01-05 Test-retest repeatability of ultrasonographic shear wave elastography in a rat liver fibrosis model: toward a quantitative biomarker for preclinical trials Shin, Youngbin Huh, Jimi Ham, Su Jung Cho, Young Chul Choi, Yoonseok Woo, Dong-Cheol Lee, Jeongjin Kim, Kyung Won Ultrasonography Original Article PURPOSE: This study evaluated the test-retest repeatability and measurement variability of ultrasonographic shear wave elastography (SWE) for liver stiffness in a rat liver fibrosis model. METHODS: In 31 Sprague-Dawley rats divided into three groups (high-dose, low-dose, and control), liver fibrosis was induced by intraperitoneal administration of thioacetamide for 8 weeks. A dedicated radiographer performed SWE to measure liver stiffness in kilopascals in two sessions at a 3-day interval. We calculated correlations between liver stiffness and histopathologic results, measurement variability in each session using coefficients of variation (CoVs) and interquartile/median (IQR/M), and test-retest repeatability between both sessions using the repeatability coefficient. RESULTS: Different levels of liver fibrosis in each group were successfully induced in the animal model. The mean liver stiffness values were 8.88±1.48 kPa in the control group, 11.62±1.70 kPa in the low-dose group, and 11.91±1.73 kPa in the high-dose group. The correlation between collagen areas and liver stiffness values was moderate (r=0.6). In all groups, the second session yielded lower CoVs (i.e., more reliable results) for liver stiffness than the first session, suggesting a training effect for the operator. The mean IQR/M values were also lower in the second session than in the first session, which had four outliers (0.21 vs. 0.12, P<0.001). The test-retest repeatability coefficient was 3.75 kPa and decreased to 2.82 kPa after removing the four outliers. CONCLUSION: The use of ultrasonographic SWE was confirmed to be feasible and repeatable for evaluating liver fibrosis in preclinical trials. Operator training might reduce variability in liver stiffness measurements. Korean Society of Ultrasound in Medicine 2021-01 2020-04-23 /pmc/articles/PMC7758098/ /pubmed/32580267 http://dx.doi.org/10.14366/usg.19088 Text en Copyright © 2021 Korean Society of Ultrasound in Medicine (KSUM) This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Shin, Youngbin
Huh, Jimi
Ham, Su Jung
Cho, Young Chul
Choi, Yoonseok
Woo, Dong-Cheol
Lee, Jeongjin
Kim, Kyung Won
Test-retest repeatability of ultrasonographic shear wave elastography in a rat liver fibrosis model: toward a quantitative biomarker for preclinical trials
title Test-retest repeatability of ultrasonographic shear wave elastography in a rat liver fibrosis model: toward a quantitative biomarker for preclinical trials
title_full Test-retest repeatability of ultrasonographic shear wave elastography in a rat liver fibrosis model: toward a quantitative biomarker for preclinical trials
title_fullStr Test-retest repeatability of ultrasonographic shear wave elastography in a rat liver fibrosis model: toward a quantitative biomarker for preclinical trials
title_full_unstemmed Test-retest repeatability of ultrasonographic shear wave elastography in a rat liver fibrosis model: toward a quantitative biomarker for preclinical trials
title_short Test-retest repeatability of ultrasonographic shear wave elastography in a rat liver fibrosis model: toward a quantitative biomarker for preclinical trials
title_sort test-retest repeatability of ultrasonographic shear wave elastography in a rat liver fibrosis model: toward a quantitative biomarker for preclinical trials
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7758098/
https://www.ncbi.nlm.nih.gov/pubmed/32580267
http://dx.doi.org/10.14366/usg.19088
work_keys_str_mv AT shinyoungbin testretestrepeatabilityofultrasonographicshearwaveelastographyinaratliverfibrosismodeltowardaquantitativebiomarkerforpreclinicaltrials
AT huhjimi testretestrepeatabilityofultrasonographicshearwaveelastographyinaratliverfibrosismodeltowardaquantitativebiomarkerforpreclinicaltrials
AT hamsujung testretestrepeatabilityofultrasonographicshearwaveelastographyinaratliverfibrosismodeltowardaquantitativebiomarkerforpreclinicaltrials
AT choyoungchul testretestrepeatabilityofultrasonographicshearwaveelastographyinaratliverfibrosismodeltowardaquantitativebiomarkerforpreclinicaltrials
AT choiyoonseok testretestrepeatabilityofultrasonographicshearwaveelastographyinaratliverfibrosismodeltowardaquantitativebiomarkerforpreclinicaltrials
AT woodongcheol testretestrepeatabilityofultrasonographicshearwaveelastographyinaratliverfibrosismodeltowardaquantitativebiomarkerforpreclinicaltrials
AT leejeongjin testretestrepeatabilityofultrasonographicshearwaveelastographyinaratliverfibrosismodeltowardaquantitativebiomarkerforpreclinicaltrials
AT kimkyungwon testretestrepeatabilityofultrasonographicshearwaveelastographyinaratliverfibrosismodeltowardaquantitativebiomarkerforpreclinicaltrials