Cargando…
Interface Pressures Derived from a Tubular Elastic Bandage
Objective: We sought to clarify the interface pressure (IP) when using a tubular elastic bandage (TEB) and examine the possibility for TEBs to provide IPs comparable to those provided by anti-thrombotic stockings. Materials and Methods: In 40 healthy patients, IPs were measured at the level of calf...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7758598/ https://www.ncbi.nlm.nih.gov/pubmed/33391559 http://dx.doi.org/10.3400/avd.oa.20-00136 |
_version_ | 1783626975794954240 |
---|---|
author | Suehiro, Kotaro Morikage, Noriyasu Harada, Takasuke Samura, Makoto Nagase, Takashi Takeuchi, Yuriko Mizoguchi, Takahiro Suzuki, Ryo Kurazumi, Hiroshi Hamano, Kimikazu |
author_facet | Suehiro, Kotaro Morikage, Noriyasu Harada, Takasuke Samura, Makoto Nagase, Takashi Takeuchi, Yuriko Mizoguchi, Takahiro Suzuki, Ryo Kurazumi, Hiroshi Hamano, Kimikazu |
author_sort | Suehiro, Kotaro |
collection | PubMed |
description | Objective: We sought to clarify the interface pressure (IP) when using a tubular elastic bandage (TEB) and examine the possibility for TEBs to provide IPs comparable to those provided by anti-thrombotic stockings. Materials and Methods: In 40 healthy patients, IPs were measured at the level of calf at its maximum diameter (C) and transition of the medial gastrocnemius muscle into the Achilles tendon (B1) while a single or double layer of TEBs (17.5 cm in circumference) were applied with the patient in a supine position. Results: Including both the C and B1 levels, circumferences and IPs showed a good correlation (single layer; r=0.72, double layer; r=0.75). The IP obtained with a single layer of TEB at the C level (median, 17 mmHg [range, 12–23 mmHg]) was higher than that at the B1 level (14 mmHg [11–18 mmHg], p<0.001). When double-layer TEB was used, the IP at B1 level increased to 18 (14–23) mmHg (p<0.001 vs. single layer). Conclusion: Considering the characteristics of TEBs and using a single or double layer appropriately, creating a pressure profile mimicking that of an anti-thrombotic stocking seemed to be feasible when using a TEB. |
format | Online Article Text |
id | pubmed-7758598 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology |
record_format | MEDLINE/PubMed |
spelling | pubmed-77585982020-12-31 Interface Pressures Derived from a Tubular Elastic Bandage Suehiro, Kotaro Morikage, Noriyasu Harada, Takasuke Samura, Makoto Nagase, Takashi Takeuchi, Yuriko Mizoguchi, Takahiro Suzuki, Ryo Kurazumi, Hiroshi Hamano, Kimikazu Ann Vasc Dis Original Article Objective: We sought to clarify the interface pressure (IP) when using a tubular elastic bandage (TEB) and examine the possibility for TEBs to provide IPs comparable to those provided by anti-thrombotic stockings. Materials and Methods: In 40 healthy patients, IPs were measured at the level of calf at its maximum diameter (C) and transition of the medial gastrocnemius muscle into the Achilles tendon (B1) while a single or double layer of TEBs (17.5 cm in circumference) were applied with the patient in a supine position. Results: Including both the C and B1 levels, circumferences and IPs showed a good correlation (single layer; r=0.72, double layer; r=0.75). The IP obtained with a single layer of TEB at the C level (median, 17 mmHg [range, 12–23 mmHg]) was higher than that at the B1 level (14 mmHg [11–18 mmHg], p<0.001). When double-layer TEB was used, the IP at B1 level increased to 18 (14–23) mmHg (p<0.001 vs. single layer). Conclusion: Considering the characteristics of TEBs and using a single or double layer appropriately, creating a pressure profile mimicking that of an anti-thrombotic stocking seemed to be feasible when using a TEB. Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology 2020-12-25 /pmc/articles/PMC7758598/ /pubmed/33391559 http://dx.doi.org/10.3400/avd.oa.20-00136 Text en © 2020 The Editorial Committee of Annals of Vascular Diseases. http://creativecommons.org/licenses/by/2.5/ This article is distributed under the terms of the Creative Commons Attribution License, which permits use, distribution, and reproduction in any medium, provided the credit of the original work, a link to the license, and indication of any change are properly given, and the original work is not used for commercial purposes. Remixed or transformed contributions must be distributed under the same license as the original. |
spellingShingle | Original Article Suehiro, Kotaro Morikage, Noriyasu Harada, Takasuke Samura, Makoto Nagase, Takashi Takeuchi, Yuriko Mizoguchi, Takahiro Suzuki, Ryo Kurazumi, Hiroshi Hamano, Kimikazu Interface Pressures Derived from a Tubular Elastic Bandage |
title | Interface Pressures Derived from a Tubular Elastic Bandage |
title_full | Interface Pressures Derived from a Tubular Elastic Bandage |
title_fullStr | Interface Pressures Derived from a Tubular Elastic Bandage |
title_full_unstemmed | Interface Pressures Derived from a Tubular Elastic Bandage |
title_short | Interface Pressures Derived from a Tubular Elastic Bandage |
title_sort | interface pressures derived from a tubular elastic bandage |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7758598/ https://www.ncbi.nlm.nih.gov/pubmed/33391559 http://dx.doi.org/10.3400/avd.oa.20-00136 |
work_keys_str_mv | AT suehirokotaro interfacepressuresderivedfromatubularelasticbandage AT morikagenoriyasu interfacepressuresderivedfromatubularelasticbandage AT haradatakasuke interfacepressuresderivedfromatubularelasticbandage AT samuramakoto interfacepressuresderivedfromatubularelasticbandage AT nagasetakashi interfacepressuresderivedfromatubularelasticbandage AT takeuchiyuriko interfacepressuresderivedfromatubularelasticbandage AT mizoguchitakahiro interfacepressuresderivedfromatubularelasticbandage AT suzukiryo interfacepressuresderivedfromatubularelasticbandage AT kurazumihiroshi interfacepressuresderivedfromatubularelasticbandage AT hamanokimikazu interfacepressuresderivedfromatubularelasticbandage |