Cargando…

Interface Pressures Derived from a Tubular Elastic Bandage

Objective: We sought to clarify the interface pressure (IP) when using a tubular elastic bandage (TEB) and examine the possibility for TEBs to provide IPs comparable to those provided by anti-thrombotic stockings. Materials and Methods: In 40 healthy patients, IPs were measured at the level of calf...

Descripción completa

Detalles Bibliográficos
Autores principales: Suehiro, Kotaro, Morikage, Noriyasu, Harada, Takasuke, Samura, Makoto, Nagase, Takashi, Takeuchi, Yuriko, Mizoguchi, Takahiro, Suzuki, Ryo, Kurazumi, Hiroshi, Hamano, Kimikazu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7758598/
https://www.ncbi.nlm.nih.gov/pubmed/33391559
http://dx.doi.org/10.3400/avd.oa.20-00136
_version_ 1783626975794954240
author Suehiro, Kotaro
Morikage, Noriyasu
Harada, Takasuke
Samura, Makoto
Nagase, Takashi
Takeuchi, Yuriko
Mizoguchi, Takahiro
Suzuki, Ryo
Kurazumi, Hiroshi
Hamano, Kimikazu
author_facet Suehiro, Kotaro
Morikage, Noriyasu
Harada, Takasuke
Samura, Makoto
Nagase, Takashi
Takeuchi, Yuriko
Mizoguchi, Takahiro
Suzuki, Ryo
Kurazumi, Hiroshi
Hamano, Kimikazu
author_sort Suehiro, Kotaro
collection PubMed
description Objective: We sought to clarify the interface pressure (IP) when using a tubular elastic bandage (TEB) and examine the possibility for TEBs to provide IPs comparable to those provided by anti-thrombotic stockings. Materials and Methods: In 40 healthy patients, IPs were measured at the level of calf at its maximum diameter (C) and transition of the medial gastrocnemius muscle into the Achilles tendon (B1) while a single or double layer of TEBs (17.5 cm in circumference) were applied with the patient in a supine position. Results: Including both the C and B1 levels, circumferences and IPs showed a good correlation (single layer; r=0.72, double layer; r=0.75). The IP obtained with a single layer of TEB at the C level (median, 17 mmHg [range, 12–23 mmHg]) was higher than that at the B1 level (14 mmHg [11–18 mmHg], p<0.001). When double-layer TEB was used, the IP at B1 level increased to 18 (14–23) mmHg (p<0.001 vs. single layer). Conclusion: Considering the characteristics of TEBs and using a single or double layer appropriately, creating a pressure profile mimicking that of an anti-thrombotic stocking seemed to be feasible when using a TEB.
format Online
Article
Text
id pubmed-7758598
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology
record_format MEDLINE/PubMed
spelling pubmed-77585982020-12-31 Interface Pressures Derived from a Tubular Elastic Bandage Suehiro, Kotaro Morikage, Noriyasu Harada, Takasuke Samura, Makoto Nagase, Takashi Takeuchi, Yuriko Mizoguchi, Takahiro Suzuki, Ryo Kurazumi, Hiroshi Hamano, Kimikazu Ann Vasc Dis Original Article Objective: We sought to clarify the interface pressure (IP) when using a tubular elastic bandage (TEB) and examine the possibility for TEBs to provide IPs comparable to those provided by anti-thrombotic stockings. Materials and Methods: In 40 healthy patients, IPs were measured at the level of calf at its maximum diameter (C) and transition of the medial gastrocnemius muscle into the Achilles tendon (B1) while a single or double layer of TEBs (17.5 cm in circumference) were applied with the patient in a supine position. Results: Including both the C and B1 levels, circumferences and IPs showed a good correlation (single layer; r=0.72, double layer; r=0.75). The IP obtained with a single layer of TEB at the C level (median, 17 mmHg [range, 12–23 mmHg]) was higher than that at the B1 level (14 mmHg [11–18 mmHg], p<0.001). When double-layer TEB was used, the IP at B1 level increased to 18 (14–23) mmHg (p<0.001 vs. single layer). Conclusion: Considering the characteristics of TEBs and using a single or double layer appropriately, creating a pressure profile mimicking that of an anti-thrombotic stocking seemed to be feasible when using a TEB. Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology 2020-12-25 /pmc/articles/PMC7758598/ /pubmed/33391559 http://dx.doi.org/10.3400/avd.oa.20-00136 Text en © 2020 The Editorial Committee of Annals of Vascular Diseases. http://creativecommons.org/licenses/by/2.5/ This article is distributed under the terms of the Creative Commons Attribution License, which permits use, distribution, and reproduction in any medium, provided the credit of the original work, a link to the license, and indication of any change are properly given, and the original work is not used for commercial purposes. Remixed or transformed contributions must be distributed under the same license as the original.
spellingShingle Original Article
Suehiro, Kotaro
Morikage, Noriyasu
Harada, Takasuke
Samura, Makoto
Nagase, Takashi
Takeuchi, Yuriko
Mizoguchi, Takahiro
Suzuki, Ryo
Kurazumi, Hiroshi
Hamano, Kimikazu
Interface Pressures Derived from a Tubular Elastic Bandage
title Interface Pressures Derived from a Tubular Elastic Bandage
title_full Interface Pressures Derived from a Tubular Elastic Bandage
title_fullStr Interface Pressures Derived from a Tubular Elastic Bandage
title_full_unstemmed Interface Pressures Derived from a Tubular Elastic Bandage
title_short Interface Pressures Derived from a Tubular Elastic Bandage
title_sort interface pressures derived from a tubular elastic bandage
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7758598/
https://www.ncbi.nlm.nih.gov/pubmed/33391559
http://dx.doi.org/10.3400/avd.oa.20-00136
work_keys_str_mv AT suehirokotaro interfacepressuresderivedfromatubularelasticbandage
AT morikagenoriyasu interfacepressuresderivedfromatubularelasticbandage
AT haradatakasuke interfacepressuresderivedfromatubularelasticbandage
AT samuramakoto interfacepressuresderivedfromatubularelasticbandage
AT nagasetakashi interfacepressuresderivedfromatubularelasticbandage
AT takeuchiyuriko interfacepressuresderivedfromatubularelasticbandage
AT mizoguchitakahiro interfacepressuresderivedfromatubularelasticbandage
AT suzukiryo interfacepressuresderivedfromatubularelasticbandage
AT kurazumihiroshi interfacepressuresderivedfromatubularelasticbandage
AT hamanokimikazu interfacepressuresderivedfromatubularelasticbandage