Fluid-Structure Interaction Simulation of an Intra-Atrial Fontan Connection
SIMPLE SUMMARY: A fluid-structure interaction (FSI) simulation of an intra-atrial Fontan connection was performed. Power loss and pressure drop results fluctuated less during the FSI simulation than during the simulation run with rigid walls, but there were no observable differences in time-averaged...
Autores principales: | Tang, Elaine, Wei, Zhenglun (Alan), Fogel, Mark A., Veneziani, Alessandro, Yoganathan, Ajit P. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7760396/ https://www.ncbi.nlm.nih.gov/pubmed/33255292 http://dx.doi.org/10.3390/biology9120412 |
Ejemplares similares
-
Respiratory pulsations affect fontan connection power loss: using real time velocity mapping to improve the accuracy of computational simulations
por: Tang, Elaine, et al.
Publicado: (2015) -
Relationship between collateral flow and exercise performance in Fontan patients: an exercise CMR study
por: Whitehead, Kevin K, et al.
Publicado: (2015) -
Growth of the inferior cavopulmonary pathway in patients with a lateral tunnel fontan connection: quantification from serial magnetic resonance images
por: Restrepo, Maria, et al.
Publicado: (2012) -
Transcatheter Hepatic Conduit-Azygous Vein Connection Reduces Pulmonary Arteriovenous Malformations in a Cyanotic Fontan Patient
por: Ratnayaka, Kanishka, et al.
Publicado: (2023) -
Strain to evaluate ventricular function in Fontan patients undergoing exercise cardiac magnetic resonance imaging
por: Anwar, Shafkat, et al.
Publicado: (2014)