Cargando…
Effects of Overlap Length on Flammability and Fire Hazard of Vertical Polymethyl Methacrylate (PMMA) Plate Array
Polymethyl methacrylate (PMMA) plates are widely used in buildings or factories for natural lighting. Commonly PMMA plates are installed as a discrete array. However, PMMA plates are very susceptible to fire. Therefore, experimental study on flammability and fire hazard of vertical PMMA plate array...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7760985/ https://www.ncbi.nlm.nih.gov/pubmed/33261199 http://dx.doi.org/10.3390/polym12122826 |
_version_ | 1783627461965119488 |
---|---|
author | An, Weiguang Hu, Kaiyang Wang, Tao Peng, Lujun Li, Song Hu, Xiangming |
author_facet | An, Weiguang Hu, Kaiyang Wang, Tao Peng, Lujun Li, Song Hu, Xiangming |
author_sort | An, Weiguang |
collection | PubMed |
description | Polymethyl methacrylate (PMMA) plates are widely used in buildings or factories for natural lighting. Commonly PMMA plates are installed as a discrete array. However, PMMA plates are very susceptible to fire. Therefore, experimental study on flammability and fire hazard of vertical PMMA plate array with different overlap length (D) was conducted in this work. The average flame height ([Formula: see text]) increases first and then decreases with an increase in the overlap length, and reaches the maximum when D = 40 mm. The discrete flame spread speed ([Formula: see text]) also rises first and then drops with the increase of D, which is mainly due to the heat transfer from the PMMA flame to the next plate. A model for predicting the flame spread rate of discrete PMMA array is established. The predicted results are consistent with experimental ones, with a predicted error smaller than 15%. The average temperature of flame zone rises first and then drops as D increases, reaching the maximum when D = 40 mm. This leads to the same changing trend of radiative heat flux. Results obtained in this work provide a reference for fire hazard evaluation and fire safety design of PMMA plates employed in buildings or industrial sites. |
format | Online Article Text |
id | pubmed-7760985 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77609852020-12-26 Effects of Overlap Length on Flammability and Fire Hazard of Vertical Polymethyl Methacrylate (PMMA) Plate Array An, Weiguang Hu, Kaiyang Wang, Tao Peng, Lujun Li, Song Hu, Xiangming Polymers (Basel) Article Polymethyl methacrylate (PMMA) plates are widely used in buildings or factories for natural lighting. Commonly PMMA plates are installed as a discrete array. However, PMMA plates are very susceptible to fire. Therefore, experimental study on flammability and fire hazard of vertical PMMA plate array with different overlap length (D) was conducted in this work. The average flame height ([Formula: see text]) increases first and then decreases with an increase in the overlap length, and reaches the maximum when D = 40 mm. The discrete flame spread speed ([Formula: see text]) also rises first and then drops with the increase of D, which is mainly due to the heat transfer from the PMMA flame to the next plate. A model for predicting the flame spread rate of discrete PMMA array is established. The predicted results are consistent with experimental ones, with a predicted error smaller than 15%. The average temperature of flame zone rises first and then drops as D increases, reaching the maximum when D = 40 mm. This leads to the same changing trend of radiative heat flux. Results obtained in this work provide a reference for fire hazard evaluation and fire safety design of PMMA plates employed in buildings or industrial sites. MDPI 2020-11-27 /pmc/articles/PMC7760985/ /pubmed/33261199 http://dx.doi.org/10.3390/polym12122826 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article An, Weiguang Hu, Kaiyang Wang, Tao Peng, Lujun Li, Song Hu, Xiangming Effects of Overlap Length on Flammability and Fire Hazard of Vertical Polymethyl Methacrylate (PMMA) Plate Array |
title | Effects of Overlap Length on Flammability and Fire Hazard of Vertical Polymethyl Methacrylate (PMMA) Plate Array |
title_full | Effects of Overlap Length on Flammability and Fire Hazard of Vertical Polymethyl Methacrylate (PMMA) Plate Array |
title_fullStr | Effects of Overlap Length on Flammability and Fire Hazard of Vertical Polymethyl Methacrylate (PMMA) Plate Array |
title_full_unstemmed | Effects of Overlap Length on Flammability and Fire Hazard of Vertical Polymethyl Methacrylate (PMMA) Plate Array |
title_short | Effects of Overlap Length on Flammability and Fire Hazard of Vertical Polymethyl Methacrylate (PMMA) Plate Array |
title_sort | effects of overlap length on flammability and fire hazard of vertical polymethyl methacrylate (pmma) plate array |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7760985/ https://www.ncbi.nlm.nih.gov/pubmed/33261199 http://dx.doi.org/10.3390/polym12122826 |
work_keys_str_mv | AT anweiguang effectsofoverlaplengthonflammabilityandfirehazardofverticalpolymethylmethacrylatepmmaplatearray AT hukaiyang effectsofoverlaplengthonflammabilityandfirehazardofverticalpolymethylmethacrylatepmmaplatearray AT wangtao effectsofoverlaplengthonflammabilityandfirehazardofverticalpolymethylmethacrylatepmmaplatearray AT penglujun effectsofoverlaplengthonflammabilityandfirehazardofverticalpolymethylmethacrylatepmmaplatearray AT lisong effectsofoverlaplengthonflammabilityandfirehazardofverticalpolymethylmethacrylatepmmaplatearray AT huxiangming effectsofoverlaplengthonflammabilityandfirehazardofverticalpolymethylmethacrylatepmmaplatearray |