Cargando…
Diagnostic Accuracy and Clinical Impact of Sentinel Lymph Node Sampling in Endometrial Cancer at High Risk of Recurrence: A Meta-Analysis
Purpose. To assess the value of sentinel lymph node (SLN) sampling in high risk endometrial cancer according to the ESMO-ESGO-ESTRO classification. Methods. We performed a comprehensive search on PubMed for clinical trials evaluating SLN sampling in patients with high risk endometrial cancer: stage...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7761304/ https://www.ncbi.nlm.nih.gov/pubmed/33260511 http://dx.doi.org/10.3390/jcm9123874 |
_version_ | 1783627537348296704 |
---|---|
author | Lecointre, Lise Lodi, Massimo Faller, Émilie Boisramé, Thomas Agnus, Vincent Baldauf, Jean-Jacques Gallix, Benoît Akladios, Chérif |
author_facet | Lecointre, Lise Lodi, Massimo Faller, Émilie Boisramé, Thomas Agnus, Vincent Baldauf, Jean-Jacques Gallix, Benoît Akladios, Chérif |
author_sort | Lecointre, Lise |
collection | PubMed |
description | Purpose. To assess the value of sentinel lymph node (SLN) sampling in high risk endometrial cancer according to the ESMO-ESGO-ESTRO classification. Methods. We performed a comprehensive search on PubMed for clinical trials evaluating SLN sampling in patients with high risk endometrial cancer: stage I endometrioid, grade 3, with at least 50% myometrial invasion, regardless of lymphovascular space invasion status; or stage II; or node-negative stage III endometrioid, no residual disease; or non-endometrioid (serous or clear cell or undifferentiated carcinoma, or carcinosarcoma). All patients underwent SLN sampling followed by pelvic with or without para-aortic lymphadenectomy. Results. We included 17 original studies concerning 1322 women. Mean detection rates were 89% for unilateral and 68% for bilateral. Pooled sensitivity was 88.5% (95%CI: 81.2–93.2%), negative predictive value was 96.0% (95%CI: 93.1–97.7%), and false negative rate was 11.5% (95%CI: 6.8; 18.8%). We noted heterogeneity in SLN techniques between studies, concerning the tracer and its detection, the injection site, the number of injections, and the surgical approach. Finally, we found a correlation between the number of patients included and the SLN sampling performances. Discussion. This meta-analysis estimated the SLN sampling performances in high risk endometrial cancer patients. Data from the literature show the feasibility, the safety, the limits, and the impact on surgical de-escalation of this technique. In conclusion, our study supports the hypothesis that SLN sampling could be a valuable technique to diagnose lymph node involvement for patients with high risk endometrial cancer in replacement of conventional lymphadenectomy. Consequently, randomized clinical trials are necessary to confirm this hypothesis. |
format | Online Article Text |
id | pubmed-7761304 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77613042020-12-26 Diagnostic Accuracy and Clinical Impact of Sentinel Lymph Node Sampling in Endometrial Cancer at High Risk of Recurrence: A Meta-Analysis Lecointre, Lise Lodi, Massimo Faller, Émilie Boisramé, Thomas Agnus, Vincent Baldauf, Jean-Jacques Gallix, Benoît Akladios, Chérif J Clin Med Review Purpose. To assess the value of sentinel lymph node (SLN) sampling in high risk endometrial cancer according to the ESMO-ESGO-ESTRO classification. Methods. We performed a comprehensive search on PubMed for clinical trials evaluating SLN sampling in patients with high risk endometrial cancer: stage I endometrioid, grade 3, with at least 50% myometrial invasion, regardless of lymphovascular space invasion status; or stage II; or node-negative stage III endometrioid, no residual disease; or non-endometrioid (serous or clear cell or undifferentiated carcinoma, or carcinosarcoma). All patients underwent SLN sampling followed by pelvic with or without para-aortic lymphadenectomy. Results. We included 17 original studies concerning 1322 women. Mean detection rates were 89% for unilateral and 68% for bilateral. Pooled sensitivity was 88.5% (95%CI: 81.2–93.2%), negative predictive value was 96.0% (95%CI: 93.1–97.7%), and false negative rate was 11.5% (95%CI: 6.8; 18.8%). We noted heterogeneity in SLN techniques between studies, concerning the tracer and its detection, the injection site, the number of injections, and the surgical approach. Finally, we found a correlation between the number of patients included and the SLN sampling performances. Discussion. This meta-analysis estimated the SLN sampling performances in high risk endometrial cancer patients. Data from the literature show the feasibility, the safety, the limits, and the impact on surgical de-escalation of this technique. In conclusion, our study supports the hypothesis that SLN sampling could be a valuable technique to diagnose lymph node involvement for patients with high risk endometrial cancer in replacement of conventional lymphadenectomy. Consequently, randomized clinical trials are necessary to confirm this hypothesis. MDPI 2020-11-28 /pmc/articles/PMC7761304/ /pubmed/33260511 http://dx.doi.org/10.3390/jcm9123874 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Lecointre, Lise Lodi, Massimo Faller, Émilie Boisramé, Thomas Agnus, Vincent Baldauf, Jean-Jacques Gallix, Benoît Akladios, Chérif Diagnostic Accuracy and Clinical Impact of Sentinel Lymph Node Sampling in Endometrial Cancer at High Risk of Recurrence: A Meta-Analysis |
title | Diagnostic Accuracy and Clinical Impact of Sentinel Lymph Node Sampling in Endometrial Cancer at High Risk of Recurrence: A Meta-Analysis |
title_full | Diagnostic Accuracy and Clinical Impact of Sentinel Lymph Node Sampling in Endometrial Cancer at High Risk of Recurrence: A Meta-Analysis |
title_fullStr | Diagnostic Accuracy and Clinical Impact of Sentinel Lymph Node Sampling in Endometrial Cancer at High Risk of Recurrence: A Meta-Analysis |
title_full_unstemmed | Diagnostic Accuracy and Clinical Impact of Sentinel Lymph Node Sampling in Endometrial Cancer at High Risk of Recurrence: A Meta-Analysis |
title_short | Diagnostic Accuracy and Clinical Impact of Sentinel Lymph Node Sampling in Endometrial Cancer at High Risk of Recurrence: A Meta-Analysis |
title_sort | diagnostic accuracy and clinical impact of sentinel lymph node sampling in endometrial cancer at high risk of recurrence: a meta-analysis |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7761304/ https://www.ncbi.nlm.nih.gov/pubmed/33260511 http://dx.doi.org/10.3390/jcm9123874 |
work_keys_str_mv | AT lecointrelise diagnosticaccuracyandclinicalimpactofsentinellymphnodesamplinginendometrialcancerathighriskofrecurrenceametaanalysis AT lodimassimo diagnosticaccuracyandclinicalimpactofsentinellymphnodesamplinginendometrialcancerathighriskofrecurrenceametaanalysis AT falleremilie diagnosticaccuracyandclinicalimpactofsentinellymphnodesamplinginendometrialcancerathighriskofrecurrenceametaanalysis AT boisramethomas diagnosticaccuracyandclinicalimpactofsentinellymphnodesamplinginendometrialcancerathighriskofrecurrenceametaanalysis AT agnusvincent diagnosticaccuracyandclinicalimpactofsentinellymphnodesamplinginendometrialcancerathighriskofrecurrenceametaanalysis AT baldaufjeanjacques diagnosticaccuracyandclinicalimpactofsentinellymphnodesamplinginendometrialcancerathighriskofrecurrenceametaanalysis AT gallixbenoit diagnosticaccuracyandclinicalimpactofsentinellymphnodesamplinginendometrialcancerathighriskofrecurrenceametaanalysis AT akladioscherif diagnosticaccuracyandclinicalimpactofsentinellymphnodesamplinginendometrialcancerathighriskofrecurrenceametaanalysis |