Cargando…

Diagnostic Accuracy and Clinical Impact of Sentinel Lymph Node Sampling in Endometrial Cancer at High Risk of Recurrence: A Meta-Analysis

Purpose. To assess the value of sentinel lymph node (SLN) sampling in high risk endometrial cancer according to the ESMO-ESGO-ESTRO classification. Methods. We performed a comprehensive search on PubMed for clinical trials evaluating SLN sampling in patients with high risk endometrial cancer: stage...

Descripción completa

Detalles Bibliográficos
Autores principales: Lecointre, Lise, Lodi, Massimo, Faller, Émilie, Boisramé, Thomas, Agnus, Vincent, Baldauf, Jean-Jacques, Gallix, Benoît, Akladios, Chérif
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7761304/
https://www.ncbi.nlm.nih.gov/pubmed/33260511
http://dx.doi.org/10.3390/jcm9123874
_version_ 1783627537348296704
author Lecointre, Lise
Lodi, Massimo
Faller, Émilie
Boisramé, Thomas
Agnus, Vincent
Baldauf, Jean-Jacques
Gallix, Benoît
Akladios, Chérif
author_facet Lecointre, Lise
Lodi, Massimo
Faller, Émilie
Boisramé, Thomas
Agnus, Vincent
Baldauf, Jean-Jacques
Gallix, Benoît
Akladios, Chérif
author_sort Lecointre, Lise
collection PubMed
description Purpose. To assess the value of sentinel lymph node (SLN) sampling in high risk endometrial cancer according to the ESMO-ESGO-ESTRO classification. Methods. We performed a comprehensive search on PubMed for clinical trials evaluating SLN sampling in patients with high risk endometrial cancer: stage I endometrioid, grade 3, with at least 50% myometrial invasion, regardless of lymphovascular space invasion status; or stage II; or node-negative stage III endometrioid, no residual disease; or non-endometrioid (serous or clear cell or undifferentiated carcinoma, or carcinosarcoma). All patients underwent SLN sampling followed by pelvic with or without para-aortic lymphadenectomy. Results. We included 17 original studies concerning 1322 women. Mean detection rates were 89% for unilateral and 68% for bilateral. Pooled sensitivity was 88.5% (95%CI: 81.2–93.2%), negative predictive value was 96.0% (95%CI: 93.1–97.7%), and false negative rate was 11.5% (95%CI: 6.8; 18.8%). We noted heterogeneity in SLN techniques between studies, concerning the tracer and its detection, the injection site, the number of injections, and the surgical approach. Finally, we found a correlation between the number of patients included and the SLN sampling performances. Discussion. This meta-analysis estimated the SLN sampling performances in high risk endometrial cancer patients. Data from the literature show the feasibility, the safety, the limits, and the impact on surgical de-escalation of this technique. In conclusion, our study supports the hypothesis that SLN sampling could be a valuable technique to diagnose lymph node involvement for patients with high risk endometrial cancer in replacement of conventional lymphadenectomy. Consequently, randomized clinical trials are necessary to confirm this hypothesis.
format Online
Article
Text
id pubmed-7761304
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77613042020-12-26 Diagnostic Accuracy and Clinical Impact of Sentinel Lymph Node Sampling in Endometrial Cancer at High Risk of Recurrence: A Meta-Analysis Lecointre, Lise Lodi, Massimo Faller, Émilie Boisramé, Thomas Agnus, Vincent Baldauf, Jean-Jacques Gallix, Benoît Akladios, Chérif J Clin Med Review Purpose. To assess the value of sentinel lymph node (SLN) sampling in high risk endometrial cancer according to the ESMO-ESGO-ESTRO classification. Methods. We performed a comprehensive search on PubMed for clinical trials evaluating SLN sampling in patients with high risk endometrial cancer: stage I endometrioid, grade 3, with at least 50% myometrial invasion, regardless of lymphovascular space invasion status; or stage II; or node-negative stage III endometrioid, no residual disease; or non-endometrioid (serous or clear cell or undifferentiated carcinoma, or carcinosarcoma). All patients underwent SLN sampling followed by pelvic with or without para-aortic lymphadenectomy. Results. We included 17 original studies concerning 1322 women. Mean detection rates were 89% for unilateral and 68% for bilateral. Pooled sensitivity was 88.5% (95%CI: 81.2–93.2%), negative predictive value was 96.0% (95%CI: 93.1–97.7%), and false negative rate was 11.5% (95%CI: 6.8; 18.8%). We noted heterogeneity in SLN techniques between studies, concerning the tracer and its detection, the injection site, the number of injections, and the surgical approach. Finally, we found a correlation between the number of patients included and the SLN sampling performances. Discussion. This meta-analysis estimated the SLN sampling performances in high risk endometrial cancer patients. Data from the literature show the feasibility, the safety, the limits, and the impact on surgical de-escalation of this technique. In conclusion, our study supports the hypothesis that SLN sampling could be a valuable technique to diagnose lymph node involvement for patients with high risk endometrial cancer in replacement of conventional lymphadenectomy. Consequently, randomized clinical trials are necessary to confirm this hypothesis. MDPI 2020-11-28 /pmc/articles/PMC7761304/ /pubmed/33260511 http://dx.doi.org/10.3390/jcm9123874 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Lecointre, Lise
Lodi, Massimo
Faller, Émilie
Boisramé, Thomas
Agnus, Vincent
Baldauf, Jean-Jacques
Gallix, Benoît
Akladios, Chérif
Diagnostic Accuracy and Clinical Impact of Sentinel Lymph Node Sampling in Endometrial Cancer at High Risk of Recurrence: A Meta-Analysis
title Diagnostic Accuracy and Clinical Impact of Sentinel Lymph Node Sampling in Endometrial Cancer at High Risk of Recurrence: A Meta-Analysis
title_full Diagnostic Accuracy and Clinical Impact of Sentinel Lymph Node Sampling in Endometrial Cancer at High Risk of Recurrence: A Meta-Analysis
title_fullStr Diagnostic Accuracy and Clinical Impact of Sentinel Lymph Node Sampling in Endometrial Cancer at High Risk of Recurrence: A Meta-Analysis
title_full_unstemmed Diagnostic Accuracy and Clinical Impact of Sentinel Lymph Node Sampling in Endometrial Cancer at High Risk of Recurrence: A Meta-Analysis
title_short Diagnostic Accuracy and Clinical Impact of Sentinel Lymph Node Sampling in Endometrial Cancer at High Risk of Recurrence: A Meta-Analysis
title_sort diagnostic accuracy and clinical impact of sentinel lymph node sampling in endometrial cancer at high risk of recurrence: a meta-analysis
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7761304/
https://www.ncbi.nlm.nih.gov/pubmed/33260511
http://dx.doi.org/10.3390/jcm9123874
work_keys_str_mv AT lecointrelise diagnosticaccuracyandclinicalimpactofsentinellymphnodesamplinginendometrialcancerathighriskofrecurrenceametaanalysis
AT lodimassimo diagnosticaccuracyandclinicalimpactofsentinellymphnodesamplinginendometrialcancerathighriskofrecurrenceametaanalysis
AT falleremilie diagnosticaccuracyandclinicalimpactofsentinellymphnodesamplinginendometrialcancerathighriskofrecurrenceametaanalysis
AT boisramethomas diagnosticaccuracyandclinicalimpactofsentinellymphnodesamplinginendometrialcancerathighriskofrecurrenceametaanalysis
AT agnusvincent diagnosticaccuracyandclinicalimpactofsentinellymphnodesamplinginendometrialcancerathighriskofrecurrenceametaanalysis
AT baldaufjeanjacques diagnosticaccuracyandclinicalimpactofsentinellymphnodesamplinginendometrialcancerathighriskofrecurrenceametaanalysis
AT gallixbenoit diagnosticaccuracyandclinicalimpactofsentinellymphnodesamplinginendometrialcancerathighriskofrecurrenceametaanalysis
AT akladioscherif diagnosticaccuracyandclinicalimpactofsentinellymphnodesamplinginendometrialcancerathighriskofrecurrenceametaanalysis