Cargando…

Clinical Feasibility of a High-Resolution Thermal Monitoring Sheet for Superficial Hyperthermia in Breast Cancer Patients

SIMPLE SUMMARY: Hyperthermia, i.e., heating tumors to 41–43 °C, combined with radiotherapy improves treatment response, for patients with recurrent breast cancer after previous irradiation. During hyperthermia of superficial tumors, the skin surface temperature must be monitored to ensure that thera...

Descripción completa

Detalles Bibliográficos
Autores principales: Bakker, Akke, Zweije, Remko, Kok, Henny Petra, Kolff, Merel Willemijn, van den Bongard, H. J. G. Desiree, Schmidt, Manfred, van Tienhoven, Geertjan, Crezee, Hans
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7761988/
https://www.ncbi.nlm.nih.gov/pubmed/33291685
http://dx.doi.org/10.3390/cancers12123644
_version_ 1783627697770987520
author Bakker, Akke
Zweije, Remko
Kok, Henny Petra
Kolff, Merel Willemijn
van den Bongard, H. J. G. Desiree
Schmidt, Manfred
van Tienhoven, Geertjan
Crezee, Hans
author_facet Bakker, Akke
Zweije, Remko
Kok, Henny Petra
Kolff, Merel Willemijn
van den Bongard, H. J. G. Desiree
Schmidt, Manfred
van Tienhoven, Geertjan
Crezee, Hans
author_sort Bakker, Akke
collection PubMed
description SIMPLE SUMMARY: Hyperthermia, i.e., heating tumors to 41–43 °C, combined with radiotherapy improves treatment response, for patients with recurrent breast cancer after previous irradiation. During hyperthermia of superficial tumors, the skin surface temperature must be monitored to ensure that therapeutic temperatures are reached without hotspots that can cause additional toxicity. A thin sheet with a dense grid of 56 temperature sensors was developed, this sheet is placed on the skin of the patient. The influence of the sheet on the hyperthermia applicator performance was investigated and found to be negligible. Next, the clinical feasibility was evaluated in 10 women with locoregional recurrent breast cancer, and resulted in precise monitoring of skin surface temperatures. In conclusion, this novel method can be implemented for thermal monitoring of the skin surface to ensure treatment quality during superficial hyperthermia treatment of patients with locoregional recurrent breast cancer. ABSTRACT: Background: Accurate monitoring of skin surface temperatures is necessary to ensure treatment quality during superficial hyperthermia. A high-resolution thermal monitoring sheet (TMS) was developed to monitor the skin surface temperature distribution. The influence of the TMS on applicator performance was investigated, feasibility and ability to reliably monitor the temperature distribution were evaluated in a clinical study. Methods: Phantom experiments were performed to determine the influence of the TMS on power deposition patterns, applicator efficiency, and heat transfer of the water bolus for 434 and 915 MHz applicators. Clinical feasibility was evaluated in 10 women with locoregional recurrent breast cancer. Skin surface temperatures during consecutive treatments were monitored alternatingly with either standard Amsterdam UMC thermometry or TMS. Treatments were compared using (generalized) linear mixed models. Results: The TMS did not significantly affect power deposition patterns and applicator efficiency (1–2%), the reduced heat transfer of the water boluses (51–56%) could be compensated by adjusting the water bolus flow. Skin surface temperatures were monitored reliably, and no alteration of thermal toxicity was observed compared to standard Amsterdam UMC thermometry. Conclusion: Clinical application of the TMS is feasible. Power deposition patterns and applicator efficiency were not affected. Surface temperatures were monitored reliably.
format Online
Article
Text
id pubmed-7761988
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77619882020-12-26 Clinical Feasibility of a High-Resolution Thermal Monitoring Sheet for Superficial Hyperthermia in Breast Cancer Patients Bakker, Akke Zweije, Remko Kok, Henny Petra Kolff, Merel Willemijn van den Bongard, H. J. G. Desiree Schmidt, Manfred van Tienhoven, Geertjan Crezee, Hans Cancers (Basel) Article SIMPLE SUMMARY: Hyperthermia, i.e., heating tumors to 41–43 °C, combined with radiotherapy improves treatment response, for patients with recurrent breast cancer after previous irradiation. During hyperthermia of superficial tumors, the skin surface temperature must be monitored to ensure that therapeutic temperatures are reached without hotspots that can cause additional toxicity. A thin sheet with a dense grid of 56 temperature sensors was developed, this sheet is placed on the skin of the patient. The influence of the sheet on the hyperthermia applicator performance was investigated and found to be negligible. Next, the clinical feasibility was evaluated in 10 women with locoregional recurrent breast cancer, and resulted in precise monitoring of skin surface temperatures. In conclusion, this novel method can be implemented for thermal monitoring of the skin surface to ensure treatment quality during superficial hyperthermia treatment of patients with locoregional recurrent breast cancer. ABSTRACT: Background: Accurate monitoring of skin surface temperatures is necessary to ensure treatment quality during superficial hyperthermia. A high-resolution thermal monitoring sheet (TMS) was developed to monitor the skin surface temperature distribution. The influence of the TMS on applicator performance was investigated, feasibility and ability to reliably monitor the temperature distribution were evaluated in a clinical study. Methods: Phantom experiments were performed to determine the influence of the TMS on power deposition patterns, applicator efficiency, and heat transfer of the water bolus for 434 and 915 MHz applicators. Clinical feasibility was evaluated in 10 women with locoregional recurrent breast cancer. Skin surface temperatures during consecutive treatments were monitored alternatingly with either standard Amsterdam UMC thermometry or TMS. Treatments were compared using (generalized) linear mixed models. Results: The TMS did not significantly affect power deposition patterns and applicator efficiency (1–2%), the reduced heat transfer of the water boluses (51–56%) could be compensated by adjusting the water bolus flow. Skin surface temperatures were monitored reliably, and no alteration of thermal toxicity was observed compared to standard Amsterdam UMC thermometry. Conclusion: Clinical application of the TMS is feasible. Power deposition patterns and applicator efficiency were not affected. Surface temperatures were monitored reliably. MDPI 2020-12-04 /pmc/articles/PMC7761988/ /pubmed/33291685 http://dx.doi.org/10.3390/cancers12123644 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bakker, Akke
Zweije, Remko
Kok, Henny Petra
Kolff, Merel Willemijn
van den Bongard, H. J. G. Desiree
Schmidt, Manfred
van Tienhoven, Geertjan
Crezee, Hans
Clinical Feasibility of a High-Resolution Thermal Monitoring Sheet for Superficial Hyperthermia in Breast Cancer Patients
title Clinical Feasibility of a High-Resolution Thermal Monitoring Sheet for Superficial Hyperthermia in Breast Cancer Patients
title_full Clinical Feasibility of a High-Resolution Thermal Monitoring Sheet for Superficial Hyperthermia in Breast Cancer Patients
title_fullStr Clinical Feasibility of a High-Resolution Thermal Monitoring Sheet for Superficial Hyperthermia in Breast Cancer Patients
title_full_unstemmed Clinical Feasibility of a High-Resolution Thermal Monitoring Sheet for Superficial Hyperthermia in Breast Cancer Patients
title_short Clinical Feasibility of a High-Resolution Thermal Monitoring Sheet for Superficial Hyperthermia in Breast Cancer Patients
title_sort clinical feasibility of a high-resolution thermal monitoring sheet for superficial hyperthermia in breast cancer patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7761988/
https://www.ncbi.nlm.nih.gov/pubmed/33291685
http://dx.doi.org/10.3390/cancers12123644
work_keys_str_mv AT bakkerakke clinicalfeasibilityofahighresolutionthermalmonitoringsheetforsuperficialhyperthermiainbreastcancerpatients
AT zweijeremko clinicalfeasibilityofahighresolutionthermalmonitoringsheetforsuperficialhyperthermiainbreastcancerpatients
AT kokhennypetra clinicalfeasibilityofahighresolutionthermalmonitoringsheetforsuperficialhyperthermiainbreastcancerpatients
AT kolffmerelwillemijn clinicalfeasibilityofahighresolutionthermalmonitoringsheetforsuperficialhyperthermiainbreastcancerpatients
AT vandenbongardhjgdesiree clinicalfeasibilityofahighresolutionthermalmonitoringsheetforsuperficialhyperthermiainbreastcancerpatients
AT schmidtmanfred clinicalfeasibilityofahighresolutionthermalmonitoringsheetforsuperficialhyperthermiainbreastcancerpatients
AT vantienhovengeertjan clinicalfeasibilityofahighresolutionthermalmonitoringsheetforsuperficialhyperthermiainbreastcancerpatients
AT crezeehans clinicalfeasibilityofahighresolutionthermalmonitoringsheetforsuperficialhyperthermiainbreastcancerpatients