Cargando…

Comparison of DMA-80 and ICP-MS Combined with Closed-Vessel Microwave Digestion for the Determination of Mercury in Coal

As one of the most widely used techniques for concentration determination of trace elements in coal, inductively coupled plasma mass spectrometry (ICP-MS) has also been used in several studies for the determination of mercury concentration in coal. ICP-MS after closed-vessel microwave digestion and...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Siyu, Zhou, Mingxuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7762631/
https://www.ncbi.nlm.nih.gov/pubmed/33381352
http://dx.doi.org/10.1155/2020/8867653
_version_ 1783627851702992896
author Zhang, Siyu
Zhou, Mingxuan
author_facet Zhang, Siyu
Zhou, Mingxuan
author_sort Zhang, Siyu
collection PubMed
description As one of the most widely used techniques for concentration determination of trace elements in coal, inductively coupled plasma mass spectrometry (ICP-MS) has also been used in several studies for the determination of mercury concentration in coal. ICP-MS after closed-vessel microwave digestion and a Milestone DMA-80 are employed in this study to determine the mercury concentration in coal. Three NIST  standard references of coal samples were selected as references to verify the accuracy of the test results. The Au rinse solution (200 μg/L, 5% HNO(3)) can diminish mercury memory effects to a blank level within 80 seconds. The results showed that ICP-MS can accurately determine the mercury content in mercury standard solutions, but the mercury concentration in most NIST samples after microwave digestion is lower than the detection level of the ICP-MS. The inaccuracy may be due to volatilization of mercury during solid sample digestion process. By contrast, the determined concentrations in NIST samples by the Milestone DMA-80 are very close to the verified values. Therefore, ICP-MS is not recommended to analyze mercury in coal after digestion even in a closed-vessel digestion system, but the mercury direct analyzer (without digestion) is recommended to analyze mercury in coal.
format Online
Article
Text
id pubmed-7762631
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-77626312020-12-29 Comparison of DMA-80 and ICP-MS Combined with Closed-Vessel Microwave Digestion for the Determination of Mercury in Coal Zhang, Siyu Zhou, Mingxuan J Anal Methods Chem Research Article As one of the most widely used techniques for concentration determination of trace elements in coal, inductively coupled plasma mass spectrometry (ICP-MS) has also been used in several studies for the determination of mercury concentration in coal. ICP-MS after closed-vessel microwave digestion and a Milestone DMA-80 are employed in this study to determine the mercury concentration in coal. Three NIST  standard references of coal samples were selected as references to verify the accuracy of the test results. The Au rinse solution (200 μg/L, 5% HNO(3)) can diminish mercury memory effects to a blank level within 80 seconds. The results showed that ICP-MS can accurately determine the mercury content in mercury standard solutions, but the mercury concentration in most NIST samples after microwave digestion is lower than the detection level of the ICP-MS. The inaccuracy may be due to volatilization of mercury during solid sample digestion process. By contrast, the determined concentrations in NIST samples by the Milestone DMA-80 are very close to the verified values. Therefore, ICP-MS is not recommended to analyze mercury in coal after digestion even in a closed-vessel digestion system, but the mercury direct analyzer (without digestion) is recommended to analyze mercury in coal. Hindawi 2020-12-18 /pmc/articles/PMC7762631/ /pubmed/33381352 http://dx.doi.org/10.1155/2020/8867653 Text en Copyright © 2020 Siyu Zhang and Mingxuan Zhou. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Zhang, Siyu
Zhou, Mingxuan
Comparison of DMA-80 and ICP-MS Combined with Closed-Vessel Microwave Digestion for the Determination of Mercury in Coal
title Comparison of DMA-80 and ICP-MS Combined with Closed-Vessel Microwave Digestion for the Determination of Mercury in Coal
title_full Comparison of DMA-80 and ICP-MS Combined with Closed-Vessel Microwave Digestion for the Determination of Mercury in Coal
title_fullStr Comparison of DMA-80 and ICP-MS Combined with Closed-Vessel Microwave Digestion for the Determination of Mercury in Coal
title_full_unstemmed Comparison of DMA-80 and ICP-MS Combined with Closed-Vessel Microwave Digestion for the Determination of Mercury in Coal
title_short Comparison of DMA-80 and ICP-MS Combined with Closed-Vessel Microwave Digestion for the Determination of Mercury in Coal
title_sort comparison of dma-80 and icp-ms combined with closed-vessel microwave digestion for the determination of mercury in coal
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7762631/
https://www.ncbi.nlm.nih.gov/pubmed/33381352
http://dx.doi.org/10.1155/2020/8867653
work_keys_str_mv AT zhangsiyu comparisonofdma80andicpmscombinedwithclosedvesselmicrowavedigestionforthedeterminationofmercuryincoal
AT zhoumingxuan comparisonofdma80andicpmscombinedwithclosedvesselmicrowavedigestionforthedeterminationofmercuryincoal