Cargando…

Masking Ability of Various Metal Complexing Ligands at 1.0 mM Concentrations on the Potentiometric Determination of Fluoride in Aqueous Samples

Fluoride is a common anion present in natural waters. Among many analytical methods used for the quantification of fluoride in natural waters, potentiometric analysis is one of the most widely used methods because of minimum interferences from other ions commonly present in natural waters. The poten...

Descripción completa

Detalles Bibliográficos
Autores principales: De Silva, Sakuni M., Deraniyagala, Samitha, Walpita, Janitha K., Jayaweera, Indira, Diyabalanage, Saranga, Cooray, Asitha T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7762639/
https://www.ncbi.nlm.nih.gov/pubmed/33381350
http://dx.doi.org/10.1155/2020/6683309
_version_ 1783627853573652480
author De Silva, Sakuni M.
Deraniyagala, Samitha
Walpita, Janitha K.
Jayaweera, Indira
Diyabalanage, Saranga
Cooray, Asitha T.
author_facet De Silva, Sakuni M.
Deraniyagala, Samitha
Walpita, Janitha K.
Jayaweera, Indira
Diyabalanage, Saranga
Cooray, Asitha T.
author_sort De Silva, Sakuni M.
collection PubMed
description Fluoride is a common anion present in natural waters. Among many analytical methods used for the quantification of fluoride in natural waters, potentiometric analysis is one of the most widely used methods because of minimum interferences from other ions commonly present in natural waters. The potentiometric analysis requires the use of ionic strength adjusting buffer abbreviated as TISAB to obtain accurate and reproducible data. In most of the reported literature, higher concentrations of strong metal chelating ligands are used as masking agents generally in the concentration range of 1.0 to 0.01 M. In the present study, effectiveness of the masking agents, phosphate, citrate, CDTA ((1,2-cyclohexylenedinitrilo)tetraacetic acid), EDTA (ethylenediaminetetraacetic acid) HE-EDTA ((hydroxyethyl)ethylenediaminetriacetic acid)), triethanolamine, and tartaric acid at 1.0 mM in TISAB solutions was investigated. The experimental data were compared with a commercially available WTW 140100 TISAB solution as the reference buffer. According to the experimental data, the reference buffer always produced the highest fluoride concentrations and the measured fluoride concentrations were in the range of 0.611 to 1.956 mg/L. Out of all the masking agents investigated, only CDTA performed marginally well and approximately a quarter of the samples produced statistically comparable data to the reference buffer. All the other masking agents produced significantly low concentrations compared to the reference buffer. The most probable reasons for the underestimation of fluoride concentrations could be shorter decomplexing time and lower masking agent concentrations.
format Online
Article
Text
id pubmed-7762639
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-77626392020-12-29 Masking Ability of Various Metal Complexing Ligands at 1.0 mM Concentrations on the Potentiometric Determination of Fluoride in Aqueous Samples De Silva, Sakuni M. Deraniyagala, Samitha Walpita, Janitha K. Jayaweera, Indira Diyabalanage, Saranga Cooray, Asitha T. J Anal Methods Chem Research Article Fluoride is a common anion present in natural waters. Among many analytical methods used for the quantification of fluoride in natural waters, potentiometric analysis is one of the most widely used methods because of minimum interferences from other ions commonly present in natural waters. The potentiometric analysis requires the use of ionic strength adjusting buffer abbreviated as TISAB to obtain accurate and reproducible data. In most of the reported literature, higher concentrations of strong metal chelating ligands are used as masking agents generally in the concentration range of 1.0 to 0.01 M. In the present study, effectiveness of the masking agents, phosphate, citrate, CDTA ((1,2-cyclohexylenedinitrilo)tetraacetic acid), EDTA (ethylenediaminetetraacetic acid) HE-EDTA ((hydroxyethyl)ethylenediaminetriacetic acid)), triethanolamine, and tartaric acid at 1.0 mM in TISAB solutions was investigated. The experimental data were compared with a commercially available WTW 140100 TISAB solution as the reference buffer. According to the experimental data, the reference buffer always produced the highest fluoride concentrations and the measured fluoride concentrations were in the range of 0.611 to 1.956 mg/L. Out of all the masking agents investigated, only CDTA performed marginally well and approximately a quarter of the samples produced statistically comparable data to the reference buffer. All the other masking agents produced significantly low concentrations compared to the reference buffer. The most probable reasons for the underestimation of fluoride concentrations could be shorter decomplexing time and lower masking agent concentrations. Hindawi 2020-12-18 /pmc/articles/PMC7762639/ /pubmed/33381350 http://dx.doi.org/10.1155/2020/6683309 Text en Copyright © 2020 Sakuni M. De Silva et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
De Silva, Sakuni M.
Deraniyagala, Samitha
Walpita, Janitha K.
Jayaweera, Indira
Diyabalanage, Saranga
Cooray, Asitha T.
Masking Ability of Various Metal Complexing Ligands at 1.0 mM Concentrations on the Potentiometric Determination of Fluoride in Aqueous Samples
title Masking Ability of Various Metal Complexing Ligands at 1.0 mM Concentrations on the Potentiometric Determination of Fluoride in Aqueous Samples
title_full Masking Ability of Various Metal Complexing Ligands at 1.0 mM Concentrations on the Potentiometric Determination of Fluoride in Aqueous Samples
title_fullStr Masking Ability of Various Metal Complexing Ligands at 1.0 mM Concentrations on the Potentiometric Determination of Fluoride in Aqueous Samples
title_full_unstemmed Masking Ability of Various Metal Complexing Ligands at 1.0 mM Concentrations on the Potentiometric Determination of Fluoride in Aqueous Samples
title_short Masking Ability of Various Metal Complexing Ligands at 1.0 mM Concentrations on the Potentiometric Determination of Fluoride in Aqueous Samples
title_sort masking ability of various metal complexing ligands at 1.0 mm concentrations on the potentiometric determination of fluoride in aqueous samples
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7762639/
https://www.ncbi.nlm.nih.gov/pubmed/33381350
http://dx.doi.org/10.1155/2020/6683309
work_keys_str_mv AT desilvasakunim maskingabilityofvariousmetalcomplexingligandsat10mmconcentrationsonthepotentiometricdeterminationoffluorideinaqueoussamples
AT deraniyagalasamitha maskingabilityofvariousmetalcomplexingligandsat10mmconcentrationsonthepotentiometricdeterminationoffluorideinaqueoussamples
AT walpitajanithak maskingabilityofvariousmetalcomplexingligandsat10mmconcentrationsonthepotentiometricdeterminationoffluorideinaqueoussamples
AT jayaweeraindira maskingabilityofvariousmetalcomplexingligandsat10mmconcentrationsonthepotentiometricdeterminationoffluorideinaqueoussamples
AT diyabalanagesaranga maskingabilityofvariousmetalcomplexingligandsat10mmconcentrationsonthepotentiometricdeterminationoffluorideinaqueoussamples
AT coorayasithat maskingabilityofvariousmetalcomplexingligandsat10mmconcentrationsonthepotentiometricdeterminationoffluorideinaqueoussamples