Cargando…

Self-Abrading Servo Electrode Helmet for Electrical Impedance Tomography

Electrical Impedance Tomography (EIT) is a medical imaging technique which has the potential to reduce time to treatment in acute stroke by rapidly differentiating between ischaemic and haemorrhagic stroke. The potential of these methods has been demonstrated in simulation and phantoms, it has not y...

Descripción completa

Detalles Bibliográficos
Autores principales: Avery, James, Packham, Brett, Koo, Hwan, Hanson, Ben, Holder, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7763319/
https://www.ncbi.nlm.nih.gov/pubmed/33317181
http://dx.doi.org/10.3390/s20247058
_version_ 1783627990363537408
author Avery, James
Packham, Brett
Koo, Hwan
Hanson, Ben
Holder, David
author_facet Avery, James
Packham, Brett
Koo, Hwan
Hanson, Ben
Holder, David
author_sort Avery, James
collection PubMed
description Electrical Impedance Tomography (EIT) is a medical imaging technique which has the potential to reduce time to treatment in acute stroke by rapidly differentiating between ischaemic and haemorrhagic stroke. The potential of these methods has been demonstrated in simulation and phantoms, it has not yet successfully translated to clinical studies, due to high sensitivity to errors in scalp electrode mislocation and poor electrode-skin contact. To overcome these limitations, a novel electrode helmet was designed, bearing 32 independently controlled self-abrading electrodes. The contact impedance was reduced through rotation on an abrasive electrode on the scalp using a combined impedance, rotation and position feedback loop. Potentiometers within each unit measure the electrode tip displacement within 0.1 mm from the rigid helmet body. Characterisation experiments on a large-scale test rig demonstrated that approximately 20 kPa applied pressure and 5 rotations was necessary to achieve the target 5 kΩ contact impedance at 20 Hz. This performance was then replicated in a simplified self-contained unit where spring loaded electrodes are rotated by servo motors. Finally, a 32-channel helmet and controller which sequentially minimised contact impedance and simultaneously located each electrode was built which reduced the electrode application and localisation time to less than five minutes. The results demonstrated the potential of this approach to rapidly apply electrodes in an acute setting, removing a significant barrier for imaging acute stroke with EIT.
format Online
Article
Text
id pubmed-7763319
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77633192020-12-27 Self-Abrading Servo Electrode Helmet for Electrical Impedance Tomography Avery, James Packham, Brett Koo, Hwan Hanson, Ben Holder, David Sensors (Basel) Article Electrical Impedance Tomography (EIT) is a medical imaging technique which has the potential to reduce time to treatment in acute stroke by rapidly differentiating between ischaemic and haemorrhagic stroke. The potential of these methods has been demonstrated in simulation and phantoms, it has not yet successfully translated to clinical studies, due to high sensitivity to errors in scalp electrode mislocation and poor electrode-skin contact. To overcome these limitations, a novel electrode helmet was designed, bearing 32 independently controlled self-abrading electrodes. The contact impedance was reduced through rotation on an abrasive electrode on the scalp using a combined impedance, rotation and position feedback loop. Potentiometers within each unit measure the electrode tip displacement within 0.1 mm from the rigid helmet body. Characterisation experiments on a large-scale test rig demonstrated that approximately 20 kPa applied pressure and 5 rotations was necessary to achieve the target 5 kΩ contact impedance at 20 Hz. This performance was then replicated in a simplified self-contained unit where spring loaded electrodes are rotated by servo motors. Finally, a 32-channel helmet and controller which sequentially minimised contact impedance and simultaneously located each electrode was built which reduced the electrode application and localisation time to less than five minutes. The results demonstrated the potential of this approach to rapidly apply electrodes in an acute setting, removing a significant barrier for imaging acute stroke with EIT. MDPI 2020-12-09 /pmc/articles/PMC7763319/ /pubmed/33317181 http://dx.doi.org/10.3390/s20247058 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Avery, James
Packham, Brett
Koo, Hwan
Hanson, Ben
Holder, David
Self-Abrading Servo Electrode Helmet for Electrical Impedance Tomography
title Self-Abrading Servo Electrode Helmet for Electrical Impedance Tomography
title_full Self-Abrading Servo Electrode Helmet for Electrical Impedance Tomography
title_fullStr Self-Abrading Servo Electrode Helmet for Electrical Impedance Tomography
title_full_unstemmed Self-Abrading Servo Electrode Helmet for Electrical Impedance Tomography
title_short Self-Abrading Servo Electrode Helmet for Electrical Impedance Tomography
title_sort self-abrading servo electrode helmet for electrical impedance tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7763319/
https://www.ncbi.nlm.nih.gov/pubmed/33317181
http://dx.doi.org/10.3390/s20247058
work_keys_str_mv AT averyjames selfabradingservoelectrodehelmetforelectricalimpedancetomography
AT packhambrett selfabradingservoelectrodehelmetforelectricalimpedancetomography
AT koohwan selfabradingservoelectrodehelmetforelectricalimpedancetomography
AT hansonben selfabradingservoelectrodehelmetforelectricalimpedancetomography
AT holderdavid selfabradingservoelectrodehelmetforelectricalimpedancetomography