Cargando…

Portable Oxygen Therapy: Is the 6-Minute Walking Test Overestimating the Actual Oxygen Needs?

The appropriate titration for the personalized oxygen needs of patients with chronic obstructive pulmonary disease (COPD) and severe hypoxemia is a determining factor in the success of long-term oxygen therapy. There are no standardized procedures to assist in determining the patient’s needs during...

Descripción completa

Detalles Bibliográficos
Autores principales: Sanchez-Morillo, Daniel, Lara-Doña, Alejandro, Priego-Torres, Blanca, Morales-Gonzalez, Maria, Montoro-Ballesteros, Francisca, Leon-Jimenez, Antonio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7764027/
https://www.ncbi.nlm.nih.gov/pubmed/33322352
http://dx.doi.org/10.3390/jcm9124007
_version_ 1783628158900109312
author Sanchez-Morillo, Daniel
Lara-Doña, Alejandro
Priego-Torres, Blanca
Morales-Gonzalez, Maria
Montoro-Ballesteros, Francisca
Leon-Jimenez, Antonio
author_facet Sanchez-Morillo, Daniel
Lara-Doña, Alejandro
Priego-Torres, Blanca
Morales-Gonzalez, Maria
Montoro-Ballesteros, Francisca
Leon-Jimenez, Antonio
author_sort Sanchez-Morillo, Daniel
collection PubMed
description The appropriate titration for the personalized oxygen needs of patients with chronic obstructive pulmonary disease (COPD) and severe hypoxemia is a determining factor in the success of long-term oxygen therapy. There are no standardized procedures to assist in determining the patient’s needs during the physical activities of daily life. Despite that effort tests are a wide broad approach, further research concerning the development of protocols to titrate O(2) therapy is needed. The main objective of this study was to assess whether the level of oxygen titrated through the 6-minute walking test (6MWT) for patients with COPD and exertional hypoxemia is adequate to meet the patients’ demand during their activities of daily living. Physiological and subjective variables were estimated for a study population during two walking tests: a 6MWT and a 20-minute walking circuit (20MWC), designed ad-hoc to reproduce daily physical activities more truthfully. The results indicate that in a significant proportion of patients, the 6MWT might not accurately predict their oxygen needs at a domiciliary environment. Therefore, the titration of the portable O(2) therapy could not be optimal in these cases, with the detrimental impact on the patient’s health (hyperoxia episodes), the autonomy of the oxygen device, and the decrease of time out of the home.
format Online
Article
Text
id pubmed-7764027
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77640272020-12-27 Portable Oxygen Therapy: Is the 6-Minute Walking Test Overestimating the Actual Oxygen Needs? Sanchez-Morillo, Daniel Lara-Doña, Alejandro Priego-Torres, Blanca Morales-Gonzalez, Maria Montoro-Ballesteros, Francisca Leon-Jimenez, Antonio J Clin Med Article The appropriate titration for the personalized oxygen needs of patients with chronic obstructive pulmonary disease (COPD) and severe hypoxemia is a determining factor in the success of long-term oxygen therapy. There are no standardized procedures to assist in determining the patient’s needs during the physical activities of daily life. Despite that effort tests are a wide broad approach, further research concerning the development of protocols to titrate O(2) therapy is needed. The main objective of this study was to assess whether the level of oxygen titrated through the 6-minute walking test (6MWT) for patients with COPD and exertional hypoxemia is adequate to meet the patients’ demand during their activities of daily living. Physiological and subjective variables were estimated for a study population during two walking tests: a 6MWT and a 20-minute walking circuit (20MWC), designed ad-hoc to reproduce daily physical activities more truthfully. The results indicate that in a significant proportion of patients, the 6MWT might not accurately predict their oxygen needs at a domiciliary environment. Therefore, the titration of the portable O(2) therapy could not be optimal in these cases, with the detrimental impact on the patient’s health (hyperoxia episodes), the autonomy of the oxygen device, and the decrease of time out of the home. MDPI 2020-12-11 /pmc/articles/PMC7764027/ /pubmed/33322352 http://dx.doi.org/10.3390/jcm9124007 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sanchez-Morillo, Daniel
Lara-Doña, Alejandro
Priego-Torres, Blanca
Morales-Gonzalez, Maria
Montoro-Ballesteros, Francisca
Leon-Jimenez, Antonio
Portable Oxygen Therapy: Is the 6-Minute Walking Test Overestimating the Actual Oxygen Needs?
title Portable Oxygen Therapy: Is the 6-Minute Walking Test Overestimating the Actual Oxygen Needs?
title_full Portable Oxygen Therapy: Is the 6-Minute Walking Test Overestimating the Actual Oxygen Needs?
title_fullStr Portable Oxygen Therapy: Is the 6-Minute Walking Test Overestimating the Actual Oxygen Needs?
title_full_unstemmed Portable Oxygen Therapy: Is the 6-Minute Walking Test Overestimating the Actual Oxygen Needs?
title_short Portable Oxygen Therapy: Is the 6-Minute Walking Test Overestimating the Actual Oxygen Needs?
title_sort portable oxygen therapy: is the 6-minute walking test overestimating the actual oxygen needs?
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7764027/
https://www.ncbi.nlm.nih.gov/pubmed/33322352
http://dx.doi.org/10.3390/jcm9124007
work_keys_str_mv AT sanchezmorillodaniel portableoxygentherapyisthe6minutewalkingtestoverestimatingtheactualoxygenneeds
AT laradonaalejandro portableoxygentherapyisthe6minutewalkingtestoverestimatingtheactualoxygenneeds
AT priegotorresblanca portableoxygentherapyisthe6minutewalkingtestoverestimatingtheactualoxygenneeds
AT moralesgonzalezmaria portableoxygentherapyisthe6minutewalkingtestoverestimatingtheactualoxygenneeds
AT montoroballesterosfrancisca portableoxygentherapyisthe6minutewalkingtestoverestimatingtheactualoxygenneeds
AT leonjimenezantonio portableoxygentherapyisthe6minutewalkingtestoverestimatingtheactualoxygenneeds