Cargando…

Diagnostic Performance of Different Simulated Low-Dose Levels in Patients with Suspected Cervical Abscess Using a Third-Generation Dual-Source CT Scanner

The aim of this study was to investigate the effects of dose reduction on diagnostic accuracy and image quality of cervical computed tomography (CT) in patients with suspected cervical abscess. Forty-eight patients (mean age 45.5 years) received a CT for suspected cervical abscess. Low-dose CT (LDCT...

Descripción completa

Detalles Bibliográficos
Autores principales: Winkelmann, Moritz T., Afat, Saif, Walter, Sven S., Stock, Eva, Schwarze, Vincent, Brendlin, Andreas, Kolb, Manuel, Artzner, Christoph P., Othman, Ahmed E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7764070/
https://www.ncbi.nlm.nih.gov/pubmed/33322074
http://dx.doi.org/10.3390/diagnostics10121072
_version_ 1783628169217048576
author Winkelmann, Moritz T.
Afat, Saif
Walter, Sven S.
Stock, Eva
Schwarze, Vincent
Brendlin, Andreas
Kolb, Manuel
Artzner, Christoph P.
Othman, Ahmed E.
author_facet Winkelmann, Moritz T.
Afat, Saif
Walter, Sven S.
Stock, Eva
Schwarze, Vincent
Brendlin, Andreas
Kolb, Manuel
Artzner, Christoph P.
Othman, Ahmed E.
author_sort Winkelmann, Moritz T.
collection PubMed
description The aim of this study was to investigate the effects of dose reduction on diagnostic accuracy and image quality of cervical computed tomography (CT) in patients with suspected cervical abscess. Forty-eight patients (mean age 45.5 years) received a CT for suspected cervical abscess. Low-dose CT (LDCT) datasets with 25%, 50%, and 75% of the original dose were generated with a realistic simulation. The image data were reconstructed with filtered back projection (FBP) and with advanced modeled iterative reconstruction (ADMIRE) (strengths 3 and 5). A five-point Likert scale was used to assess subjective image quality and diagnostic confidence. The signal-to-noise ratio (SNR) of the sternocleidomastoid muscle and submandibular gland and the contrast-to-noise ratio (CNR) of the sternocleidomastoid muscle and submandibular glandular fat were calculated to assess the objective image quality. Diagnostic accuracy was calculated for LDCT using the original dose as the reference standard. The prevalence of cervical abscesses was high (72.9%) in the cohort; the mean effective dose for all 48 scans was 1.8 ± 0.8 mSv. Sternocleidomastoid and submandibular SNR and sternocleidomastoid muscle fat and submandibular gland fat CNR increased with higher doses and were significantly higher for ADMIRE compared to FBP, with the best results in ADMIRE 5 (all p < 0.001). Subjective image quality was highest for ADMIRE 5 at 75% and lowest for FBP at 25% of the original dose (p < 0.001). Diagnostic confidence was highest for ADMIRE 5 at 75% and lowest for FBP at 25% (p < 0.001). Patient-based diagnostic accuracy was high for all LDCT datasets, down to 25% for ADMIRE 3 and 5 (sensitivity: 100%; specificity: 100%) and lower for FBP at 25% dose reduction (sensitivity: 88.6–94.3%; specificity: 92.3–100%). The use of a modern dual-source CT of the third generation and iterative reconstruction allows a reduction in the radiation dose to 25% (0.5 mSv) of the original dose with the same diagnostic accuracy for the assessment of neck abscesses.
format Online
Article
Text
id pubmed-7764070
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77640702020-12-27 Diagnostic Performance of Different Simulated Low-Dose Levels in Patients with Suspected Cervical Abscess Using a Third-Generation Dual-Source CT Scanner Winkelmann, Moritz T. Afat, Saif Walter, Sven S. Stock, Eva Schwarze, Vincent Brendlin, Andreas Kolb, Manuel Artzner, Christoph P. Othman, Ahmed E. Diagnostics (Basel) Article The aim of this study was to investigate the effects of dose reduction on diagnostic accuracy and image quality of cervical computed tomography (CT) in patients with suspected cervical abscess. Forty-eight patients (mean age 45.5 years) received a CT for suspected cervical abscess. Low-dose CT (LDCT) datasets with 25%, 50%, and 75% of the original dose were generated with a realistic simulation. The image data were reconstructed with filtered back projection (FBP) and with advanced modeled iterative reconstruction (ADMIRE) (strengths 3 and 5). A five-point Likert scale was used to assess subjective image quality and diagnostic confidence. The signal-to-noise ratio (SNR) of the sternocleidomastoid muscle and submandibular gland and the contrast-to-noise ratio (CNR) of the sternocleidomastoid muscle and submandibular glandular fat were calculated to assess the objective image quality. Diagnostic accuracy was calculated for LDCT using the original dose as the reference standard. The prevalence of cervical abscesses was high (72.9%) in the cohort; the mean effective dose for all 48 scans was 1.8 ± 0.8 mSv. Sternocleidomastoid and submandibular SNR and sternocleidomastoid muscle fat and submandibular gland fat CNR increased with higher doses and were significantly higher for ADMIRE compared to FBP, with the best results in ADMIRE 5 (all p < 0.001). Subjective image quality was highest for ADMIRE 5 at 75% and lowest for FBP at 25% of the original dose (p < 0.001). Diagnostic confidence was highest for ADMIRE 5 at 75% and lowest for FBP at 25% (p < 0.001). Patient-based diagnostic accuracy was high for all LDCT datasets, down to 25% for ADMIRE 3 and 5 (sensitivity: 100%; specificity: 100%) and lower for FBP at 25% dose reduction (sensitivity: 88.6–94.3%; specificity: 92.3–100%). The use of a modern dual-source CT of the third generation and iterative reconstruction allows a reduction in the radiation dose to 25% (0.5 mSv) of the original dose with the same diagnostic accuracy for the assessment of neck abscesses. MDPI 2020-12-10 /pmc/articles/PMC7764070/ /pubmed/33322074 http://dx.doi.org/10.3390/diagnostics10121072 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Winkelmann, Moritz T.
Afat, Saif
Walter, Sven S.
Stock, Eva
Schwarze, Vincent
Brendlin, Andreas
Kolb, Manuel
Artzner, Christoph P.
Othman, Ahmed E.
Diagnostic Performance of Different Simulated Low-Dose Levels in Patients with Suspected Cervical Abscess Using a Third-Generation Dual-Source CT Scanner
title Diagnostic Performance of Different Simulated Low-Dose Levels in Patients with Suspected Cervical Abscess Using a Third-Generation Dual-Source CT Scanner
title_full Diagnostic Performance of Different Simulated Low-Dose Levels in Patients with Suspected Cervical Abscess Using a Third-Generation Dual-Source CT Scanner
title_fullStr Diagnostic Performance of Different Simulated Low-Dose Levels in Patients with Suspected Cervical Abscess Using a Third-Generation Dual-Source CT Scanner
title_full_unstemmed Diagnostic Performance of Different Simulated Low-Dose Levels in Patients with Suspected Cervical Abscess Using a Third-Generation Dual-Source CT Scanner
title_short Diagnostic Performance of Different Simulated Low-Dose Levels in Patients with Suspected Cervical Abscess Using a Third-Generation Dual-Source CT Scanner
title_sort diagnostic performance of different simulated low-dose levels in patients with suspected cervical abscess using a third-generation dual-source ct scanner
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7764070/
https://www.ncbi.nlm.nih.gov/pubmed/33322074
http://dx.doi.org/10.3390/diagnostics10121072
work_keys_str_mv AT winkelmannmoritzt diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner
AT afatsaif diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner
AT waltersvens diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner
AT stockeva diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner
AT schwarzevincent diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner
AT brendlinandreas diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner
AT kolbmanuel diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner
AT artznerchristophp diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner
AT othmanahmede diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner