Cargando…
Diagnostic Performance of Different Simulated Low-Dose Levels in Patients with Suspected Cervical Abscess Using a Third-Generation Dual-Source CT Scanner
The aim of this study was to investigate the effects of dose reduction on diagnostic accuracy and image quality of cervical computed tomography (CT) in patients with suspected cervical abscess. Forty-eight patients (mean age 45.5 years) received a CT for suspected cervical abscess. Low-dose CT (LDCT...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7764070/ https://www.ncbi.nlm.nih.gov/pubmed/33322074 http://dx.doi.org/10.3390/diagnostics10121072 |
_version_ | 1783628169217048576 |
---|---|
author | Winkelmann, Moritz T. Afat, Saif Walter, Sven S. Stock, Eva Schwarze, Vincent Brendlin, Andreas Kolb, Manuel Artzner, Christoph P. Othman, Ahmed E. |
author_facet | Winkelmann, Moritz T. Afat, Saif Walter, Sven S. Stock, Eva Schwarze, Vincent Brendlin, Andreas Kolb, Manuel Artzner, Christoph P. Othman, Ahmed E. |
author_sort | Winkelmann, Moritz T. |
collection | PubMed |
description | The aim of this study was to investigate the effects of dose reduction on diagnostic accuracy and image quality of cervical computed tomography (CT) in patients with suspected cervical abscess. Forty-eight patients (mean age 45.5 years) received a CT for suspected cervical abscess. Low-dose CT (LDCT) datasets with 25%, 50%, and 75% of the original dose were generated with a realistic simulation. The image data were reconstructed with filtered back projection (FBP) and with advanced modeled iterative reconstruction (ADMIRE) (strengths 3 and 5). A five-point Likert scale was used to assess subjective image quality and diagnostic confidence. The signal-to-noise ratio (SNR) of the sternocleidomastoid muscle and submandibular gland and the contrast-to-noise ratio (CNR) of the sternocleidomastoid muscle and submandibular glandular fat were calculated to assess the objective image quality. Diagnostic accuracy was calculated for LDCT using the original dose as the reference standard. The prevalence of cervical abscesses was high (72.9%) in the cohort; the mean effective dose for all 48 scans was 1.8 ± 0.8 mSv. Sternocleidomastoid and submandibular SNR and sternocleidomastoid muscle fat and submandibular gland fat CNR increased with higher doses and were significantly higher for ADMIRE compared to FBP, with the best results in ADMIRE 5 (all p < 0.001). Subjective image quality was highest for ADMIRE 5 at 75% and lowest for FBP at 25% of the original dose (p < 0.001). Diagnostic confidence was highest for ADMIRE 5 at 75% and lowest for FBP at 25% (p < 0.001). Patient-based diagnostic accuracy was high for all LDCT datasets, down to 25% for ADMIRE 3 and 5 (sensitivity: 100%; specificity: 100%) and lower for FBP at 25% dose reduction (sensitivity: 88.6–94.3%; specificity: 92.3–100%). The use of a modern dual-source CT of the third generation and iterative reconstruction allows a reduction in the radiation dose to 25% (0.5 mSv) of the original dose with the same diagnostic accuracy for the assessment of neck abscesses. |
format | Online Article Text |
id | pubmed-7764070 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77640702020-12-27 Diagnostic Performance of Different Simulated Low-Dose Levels in Patients with Suspected Cervical Abscess Using a Third-Generation Dual-Source CT Scanner Winkelmann, Moritz T. Afat, Saif Walter, Sven S. Stock, Eva Schwarze, Vincent Brendlin, Andreas Kolb, Manuel Artzner, Christoph P. Othman, Ahmed E. Diagnostics (Basel) Article The aim of this study was to investigate the effects of dose reduction on diagnostic accuracy and image quality of cervical computed tomography (CT) in patients with suspected cervical abscess. Forty-eight patients (mean age 45.5 years) received a CT for suspected cervical abscess. Low-dose CT (LDCT) datasets with 25%, 50%, and 75% of the original dose were generated with a realistic simulation. The image data were reconstructed with filtered back projection (FBP) and with advanced modeled iterative reconstruction (ADMIRE) (strengths 3 and 5). A five-point Likert scale was used to assess subjective image quality and diagnostic confidence. The signal-to-noise ratio (SNR) of the sternocleidomastoid muscle and submandibular gland and the contrast-to-noise ratio (CNR) of the sternocleidomastoid muscle and submandibular glandular fat were calculated to assess the objective image quality. Diagnostic accuracy was calculated for LDCT using the original dose as the reference standard. The prevalence of cervical abscesses was high (72.9%) in the cohort; the mean effective dose for all 48 scans was 1.8 ± 0.8 mSv. Sternocleidomastoid and submandibular SNR and sternocleidomastoid muscle fat and submandibular gland fat CNR increased with higher doses and were significantly higher for ADMIRE compared to FBP, with the best results in ADMIRE 5 (all p < 0.001). Subjective image quality was highest for ADMIRE 5 at 75% and lowest for FBP at 25% of the original dose (p < 0.001). Diagnostic confidence was highest for ADMIRE 5 at 75% and lowest for FBP at 25% (p < 0.001). Patient-based diagnostic accuracy was high for all LDCT datasets, down to 25% for ADMIRE 3 and 5 (sensitivity: 100%; specificity: 100%) and lower for FBP at 25% dose reduction (sensitivity: 88.6–94.3%; specificity: 92.3–100%). The use of a modern dual-source CT of the third generation and iterative reconstruction allows a reduction in the radiation dose to 25% (0.5 mSv) of the original dose with the same diagnostic accuracy for the assessment of neck abscesses. MDPI 2020-12-10 /pmc/articles/PMC7764070/ /pubmed/33322074 http://dx.doi.org/10.3390/diagnostics10121072 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Winkelmann, Moritz T. Afat, Saif Walter, Sven S. Stock, Eva Schwarze, Vincent Brendlin, Andreas Kolb, Manuel Artzner, Christoph P. Othman, Ahmed E. Diagnostic Performance of Different Simulated Low-Dose Levels in Patients with Suspected Cervical Abscess Using a Third-Generation Dual-Source CT Scanner |
title | Diagnostic Performance of Different Simulated Low-Dose Levels in Patients with Suspected Cervical Abscess Using a Third-Generation Dual-Source CT Scanner |
title_full | Diagnostic Performance of Different Simulated Low-Dose Levels in Patients with Suspected Cervical Abscess Using a Third-Generation Dual-Source CT Scanner |
title_fullStr | Diagnostic Performance of Different Simulated Low-Dose Levels in Patients with Suspected Cervical Abscess Using a Third-Generation Dual-Source CT Scanner |
title_full_unstemmed | Diagnostic Performance of Different Simulated Low-Dose Levels in Patients with Suspected Cervical Abscess Using a Third-Generation Dual-Source CT Scanner |
title_short | Diagnostic Performance of Different Simulated Low-Dose Levels in Patients with Suspected Cervical Abscess Using a Third-Generation Dual-Source CT Scanner |
title_sort | diagnostic performance of different simulated low-dose levels in patients with suspected cervical abscess using a third-generation dual-source ct scanner |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7764070/ https://www.ncbi.nlm.nih.gov/pubmed/33322074 http://dx.doi.org/10.3390/diagnostics10121072 |
work_keys_str_mv | AT winkelmannmoritzt diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner AT afatsaif diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner AT waltersvens diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner AT stockeva diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner AT schwarzevincent diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner AT brendlinandreas diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner AT kolbmanuel diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner AT artznerchristophp diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner AT othmanahmede diagnosticperformanceofdifferentsimulatedlowdoselevelsinpatientswithsuspectedcervicalabscessusingathirdgenerationdualsourcectscanner |