Cargando…
Error Estimation of Ultra-Short Heart Rate Variability Parameters: Effect of Missing Data Caused by Motion Artifacts
Application of ultra–short Heart Rate Variability (HRV) is desirable in order to increase the applicability of HRV features to wrist-worn wearable devices equipped with heart rate sensors that are nowadays becoming more and more popular in people’s daily life. This study is focused in particular on...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7764161/ https://www.ncbi.nlm.nih.gov/pubmed/33322560 http://dx.doi.org/10.3390/s20247122 |
_version_ | 1783628191053643776 |
---|---|
author | Rossi, Alessio Pedreschi, Dino Clifton, David A. Morelli, Davide |
author_facet | Rossi, Alessio Pedreschi, Dino Clifton, David A. Morelli, Davide |
author_sort | Rossi, Alessio |
collection | PubMed |
description | Application of ultra–short Heart Rate Variability (HRV) is desirable in order to increase the applicability of HRV features to wrist-worn wearable devices equipped with heart rate sensors that are nowadays becoming more and more popular in people’s daily life. This study is focused in particular on the the two most used HRV parameters, i.e., the standard deviation of inter-beat intervals (SDNN) and the root Mean Squared error of successive inter-beat intervals differences (rMSSD). The huge problem of extracting these HRV parameters from wrist-worn devices is that their data are affected by the motion artifacts. For this reason, estimating the error caused by this huge quantity of missing values is fundamental to obtain reliable HRV parameters from these devices. To this aim, we simulate missing values induced by motion artifacts (from 0 to 70%) in an ultra-short time window (i.e., from 4 min to 30 s) by the random walk Gilbert burst model in 22 young healthy subjects. In addition, 30 s and 2 min ultra-short time windows are required to estimate rMSSD and SDNN, respectively. Moreover, due to the fact that ultra-short time window does not permit assessing very low frequencies, and the SDNN is highly affected by these frequencies, the bias for estimating SDNN continues to increase as the time window length decreases. On the contrary, a small error is detected in rMSSD up to 30 s due to the fact that it is highly affected by high frequencies which are possible to be evaluated even if the time window length decreases. Finally, the missing values have a small effect on rMSSD and SDNN estimation. As a matter of fact, the HRV parameter errors increase slightly as the percentage of missing values increase. |
format | Online Article Text |
id | pubmed-7764161 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77641612020-12-27 Error Estimation of Ultra-Short Heart Rate Variability Parameters: Effect of Missing Data Caused by Motion Artifacts Rossi, Alessio Pedreschi, Dino Clifton, David A. Morelli, Davide Sensors (Basel) Communication Application of ultra–short Heart Rate Variability (HRV) is desirable in order to increase the applicability of HRV features to wrist-worn wearable devices equipped with heart rate sensors that are nowadays becoming more and more popular in people’s daily life. This study is focused in particular on the the two most used HRV parameters, i.e., the standard deviation of inter-beat intervals (SDNN) and the root Mean Squared error of successive inter-beat intervals differences (rMSSD). The huge problem of extracting these HRV parameters from wrist-worn devices is that their data are affected by the motion artifacts. For this reason, estimating the error caused by this huge quantity of missing values is fundamental to obtain reliable HRV parameters from these devices. To this aim, we simulate missing values induced by motion artifacts (from 0 to 70%) in an ultra-short time window (i.e., from 4 min to 30 s) by the random walk Gilbert burst model in 22 young healthy subjects. In addition, 30 s and 2 min ultra-short time windows are required to estimate rMSSD and SDNN, respectively. Moreover, due to the fact that ultra-short time window does not permit assessing very low frequencies, and the SDNN is highly affected by these frequencies, the bias for estimating SDNN continues to increase as the time window length decreases. On the contrary, a small error is detected in rMSSD up to 30 s due to the fact that it is highly affected by high frequencies which are possible to be evaluated even if the time window length decreases. Finally, the missing values have a small effect on rMSSD and SDNN estimation. As a matter of fact, the HRV parameter errors increase slightly as the percentage of missing values increase. MDPI 2020-12-11 /pmc/articles/PMC7764161/ /pubmed/33322560 http://dx.doi.org/10.3390/s20247122 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Communication Rossi, Alessio Pedreschi, Dino Clifton, David A. Morelli, Davide Error Estimation of Ultra-Short Heart Rate Variability Parameters: Effect of Missing Data Caused by Motion Artifacts |
title | Error Estimation of Ultra-Short Heart Rate Variability Parameters: Effect of Missing Data Caused by Motion Artifacts |
title_full | Error Estimation of Ultra-Short Heart Rate Variability Parameters: Effect of Missing Data Caused by Motion Artifacts |
title_fullStr | Error Estimation of Ultra-Short Heart Rate Variability Parameters: Effect of Missing Data Caused by Motion Artifacts |
title_full_unstemmed | Error Estimation of Ultra-Short Heart Rate Variability Parameters: Effect of Missing Data Caused by Motion Artifacts |
title_short | Error Estimation of Ultra-Short Heart Rate Variability Parameters: Effect of Missing Data Caused by Motion Artifacts |
title_sort | error estimation of ultra-short heart rate variability parameters: effect of missing data caused by motion artifacts |
topic | Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7764161/ https://www.ncbi.nlm.nih.gov/pubmed/33322560 http://dx.doi.org/10.3390/s20247122 |
work_keys_str_mv | AT rossialessio errorestimationofultrashortheartratevariabilityparameterseffectofmissingdatacausedbymotionartifacts AT pedreschidino errorestimationofultrashortheartratevariabilityparameterseffectofmissingdatacausedbymotionartifacts AT cliftondavida errorestimationofultrashortheartratevariabilityparameterseffectofmissingdatacausedbymotionartifacts AT morellidavide errorestimationofultrashortheartratevariabilityparameterseffectofmissingdatacausedbymotionartifacts |