Cargando…

Sensitive Analysis of Idarubicin in Human Urine and Plasma by Liquid Chromatography with Fluorescence Detection: An Application in Drug Monitoring

A new approach for the sensitive, robust and rapid determination of idarubicin (IDA) in human plasma and urine samples based on liquid chromatography with fluorescence detection (LC-FL) was developed. Satisfactory chromatographic separation of the analyte after solid-phase extraction (SPE) was perfo...

Descripción completa

Detalles Bibliográficos
Autores principales: Maliszewska, Olga, Treder, Natalia, Olędzka, IIona, Kowalski, Piotr, Miękus, Natalia, Bączek, Tomasz, Rodzaj, Wojciech, Bień, Ewa, Krawczyk, Małgorzata Anna, Plenis, Alina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7764277/
https://www.ncbi.nlm.nih.gov/pubmed/33316898
http://dx.doi.org/10.3390/molecules25245799
_version_ 1783628218631192576
author Maliszewska, Olga
Treder, Natalia
Olędzka, IIona
Kowalski, Piotr
Miękus, Natalia
Bączek, Tomasz
Rodzaj, Wojciech
Bień, Ewa
Krawczyk, Małgorzata Anna
Plenis, Alina
author_facet Maliszewska, Olga
Treder, Natalia
Olędzka, IIona
Kowalski, Piotr
Miękus, Natalia
Bączek, Tomasz
Rodzaj, Wojciech
Bień, Ewa
Krawczyk, Małgorzata Anna
Plenis, Alina
author_sort Maliszewska, Olga
collection PubMed
description A new approach for the sensitive, robust and rapid determination of idarubicin (IDA) in human plasma and urine samples based on liquid chromatography with fluorescence detection (LC-FL) was developed. Satisfactory chromatographic separation of the analyte after solid-phase extraction (SPE) was performed on a Discovery HS C18 analytical column using a mixture of acetonitrile and 0.1% formic acid in water as the mobile phase in isocratic mode. IDA and daunorubicin hydrochloride used as an internal standard (I.S.) were monitored at the excitation and emission wavelengths of 487 and 547 nm, respectively. The method was validated according to the FDA and ICH guidelines. The linearity was confirmed in the range of 0.1–50 ng/mL and 0.25–200 ng/mL, while the limit of detection (LOD) was 0.05 and 0.125 ng/mL in plasma and urine samples, respectively. The developed LC-FL method was successfully applied for drug determinations in human plasma and urine after oral administration of IDA at a dose of 10 mg to a patient with highly advanced alveolar rhabdomyosarcoma (RMA). Moreover, the potential exposure to IDA present in both fluids for healthcare workers and the caregivers of patients has been evaluated. The present LC-FL method can be a useful tool in pharmacokinetic and clinical investigations, in the monitoring of chemotherapy containing IDA, as well as for sensitive and reliable IDA quantitation in biological fluids.
format Online
Article
Text
id pubmed-7764277
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77642772020-12-27 Sensitive Analysis of Idarubicin in Human Urine and Plasma by Liquid Chromatography with Fluorescence Detection: An Application in Drug Monitoring Maliszewska, Olga Treder, Natalia Olędzka, IIona Kowalski, Piotr Miękus, Natalia Bączek, Tomasz Rodzaj, Wojciech Bień, Ewa Krawczyk, Małgorzata Anna Plenis, Alina Molecules Article A new approach for the sensitive, robust and rapid determination of idarubicin (IDA) in human plasma and urine samples based on liquid chromatography with fluorescence detection (LC-FL) was developed. Satisfactory chromatographic separation of the analyte after solid-phase extraction (SPE) was performed on a Discovery HS C18 analytical column using a mixture of acetonitrile and 0.1% formic acid in water as the mobile phase in isocratic mode. IDA and daunorubicin hydrochloride used as an internal standard (I.S.) were monitored at the excitation and emission wavelengths of 487 and 547 nm, respectively. The method was validated according to the FDA and ICH guidelines. The linearity was confirmed in the range of 0.1–50 ng/mL and 0.25–200 ng/mL, while the limit of detection (LOD) was 0.05 and 0.125 ng/mL in plasma and urine samples, respectively. The developed LC-FL method was successfully applied for drug determinations in human plasma and urine after oral administration of IDA at a dose of 10 mg to a patient with highly advanced alveolar rhabdomyosarcoma (RMA). Moreover, the potential exposure to IDA present in both fluids for healthcare workers and the caregivers of patients has been evaluated. The present LC-FL method can be a useful tool in pharmacokinetic and clinical investigations, in the monitoring of chemotherapy containing IDA, as well as for sensitive and reliable IDA quantitation in biological fluids. MDPI 2020-12-09 /pmc/articles/PMC7764277/ /pubmed/33316898 http://dx.doi.org/10.3390/molecules25245799 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Maliszewska, Olga
Treder, Natalia
Olędzka, IIona
Kowalski, Piotr
Miękus, Natalia
Bączek, Tomasz
Rodzaj, Wojciech
Bień, Ewa
Krawczyk, Małgorzata Anna
Plenis, Alina
Sensitive Analysis of Idarubicin in Human Urine and Plasma by Liquid Chromatography with Fluorescence Detection: An Application in Drug Monitoring
title Sensitive Analysis of Idarubicin in Human Urine and Plasma by Liquid Chromatography with Fluorescence Detection: An Application in Drug Monitoring
title_full Sensitive Analysis of Idarubicin in Human Urine and Plasma by Liquid Chromatography with Fluorescence Detection: An Application in Drug Monitoring
title_fullStr Sensitive Analysis of Idarubicin in Human Urine and Plasma by Liquid Chromatography with Fluorescence Detection: An Application in Drug Monitoring
title_full_unstemmed Sensitive Analysis of Idarubicin in Human Urine and Plasma by Liquid Chromatography with Fluorescence Detection: An Application in Drug Monitoring
title_short Sensitive Analysis of Idarubicin in Human Urine and Plasma by Liquid Chromatography with Fluorescence Detection: An Application in Drug Monitoring
title_sort sensitive analysis of idarubicin in human urine and plasma by liquid chromatography with fluorescence detection: an application in drug monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7764277/
https://www.ncbi.nlm.nih.gov/pubmed/33316898
http://dx.doi.org/10.3390/molecules25245799
work_keys_str_mv AT maliszewskaolga sensitiveanalysisofidarubicininhumanurineandplasmabyliquidchromatographywithfluorescencedetectionanapplicationindrugmonitoring
AT tredernatalia sensitiveanalysisofidarubicininhumanurineandplasmabyliquidchromatographywithfluorescencedetectionanapplicationindrugmonitoring
AT oledzkaiiona sensitiveanalysisofidarubicininhumanurineandplasmabyliquidchromatographywithfluorescencedetectionanapplicationindrugmonitoring
AT kowalskipiotr sensitiveanalysisofidarubicininhumanurineandplasmabyliquidchromatographywithfluorescencedetectionanapplicationindrugmonitoring
AT miekusnatalia sensitiveanalysisofidarubicininhumanurineandplasmabyliquidchromatographywithfluorescencedetectionanapplicationindrugmonitoring
AT baczektomasz sensitiveanalysisofidarubicininhumanurineandplasmabyliquidchromatographywithfluorescencedetectionanapplicationindrugmonitoring
AT rodzajwojciech sensitiveanalysisofidarubicininhumanurineandplasmabyliquidchromatographywithfluorescencedetectionanapplicationindrugmonitoring
AT bienewa sensitiveanalysisofidarubicininhumanurineandplasmabyliquidchromatographywithfluorescencedetectionanapplicationindrugmonitoring
AT krawczykmałgorzataanna sensitiveanalysisofidarubicininhumanurineandplasmabyliquidchromatographywithfluorescencedetectionanapplicationindrugmonitoring
AT plenisalina sensitiveanalysisofidarubicininhumanurineandplasmabyliquidchromatographywithfluorescencedetectionanapplicationindrugmonitoring