Cargando…

Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes

Rotary tables are often used to speed up the acquisition time during the 3D scanning of complex geometries. In order to avoid manual registration of the point clouds acquired with different orientations, automatic algorithms to compensate the rotation were developed. Alternatively, a proper calibrat...

Descripción completa

Detalles Bibliográficos
Autores principales: Bisogni, Livio, Mollaiyan, Ramtin, Pettinari, Matteo, Neri, Paolo, Gabiccini, Marco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7764672/
https://www.ncbi.nlm.nih.gov/pubmed/33322387
http://dx.doi.org/10.3390/s20247107
_version_ 1783628312217649152
author Bisogni, Livio
Mollaiyan, Ramtin
Pettinari, Matteo
Neri, Paolo
Gabiccini, Marco
author_facet Bisogni, Livio
Mollaiyan, Ramtin
Pettinari, Matteo
Neri, Paolo
Gabiccini, Marco
author_sort Bisogni, Livio
collection PubMed
description Rotary tables are often used to speed up the acquisition time during the 3D scanning of complex geometries. In order to avoid manual registration of the point clouds acquired with different orientations, automatic algorithms to compensate the rotation were developed. Alternatively, a proper calibration of the rotary axis with respect to the camera system is needed. Several methods are available in the literature, but they only consider a single-axis calibration. In this paper, a method for the simultaneous calibration of both axes of the table is proposed. A checkerboard is attached to the table, and several images with different poses are acquired. An optimization algorithm is then setup to determine the orientation and the locations of the two axes. A metric to assess the calibration quality was also defined by computing the average mean reprojection error. This metric is used to investigate the optimal number and distribution of the calibration poses, demonstrating that the optimum calibration results are achieved when a wider dispersion of the calibration poses is adopted.
format Online
Article
Text
id pubmed-7764672
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77646722020-12-27 Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes Bisogni, Livio Mollaiyan, Ramtin Pettinari, Matteo Neri, Paolo Gabiccini, Marco Sensors (Basel) Article Rotary tables are often used to speed up the acquisition time during the 3D scanning of complex geometries. In order to avoid manual registration of the point clouds acquired with different orientations, automatic algorithms to compensate the rotation were developed. Alternatively, a proper calibration of the rotary axis with respect to the camera system is needed. Several methods are available in the literature, but they only consider a single-axis calibration. In this paper, a method for the simultaneous calibration of both axes of the table is proposed. A checkerboard is attached to the table, and several images with different poses are acquired. An optimization algorithm is then setup to determine the orientation and the locations of the two axes. A metric to assess the calibration quality was also defined by computing the average mean reprojection error. This metric is used to investigate the optimal number and distribution of the calibration poses, demonstrating that the optimum calibration results are achieved when a wider dispersion of the calibration poses is adopted. MDPI 2020-12-11 /pmc/articles/PMC7764672/ /pubmed/33322387 http://dx.doi.org/10.3390/s20247107 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bisogni, Livio
Mollaiyan, Ramtin
Pettinari, Matteo
Neri, Paolo
Gabiccini, Marco
Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes
title Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes
title_full Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes
title_fullStr Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes
title_full_unstemmed Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes
title_short Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes
title_sort automatic calibration of a two-axis rotary table for 3d scanning purposes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7764672/
https://www.ncbi.nlm.nih.gov/pubmed/33322387
http://dx.doi.org/10.3390/s20247107
work_keys_str_mv AT bisognilivio automaticcalibrationofatwoaxisrotarytablefor3dscanningpurposes
AT mollaiyanramtin automaticcalibrationofatwoaxisrotarytablefor3dscanningpurposes
AT pettinarimatteo automaticcalibrationofatwoaxisrotarytablefor3dscanningpurposes
AT neripaolo automaticcalibrationofatwoaxisrotarytablefor3dscanningpurposes
AT gabiccinimarco automaticcalibrationofatwoaxisrotarytablefor3dscanningpurposes