Cargando…
Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes
Rotary tables are often used to speed up the acquisition time during the 3D scanning of complex geometries. In order to avoid manual registration of the point clouds acquired with different orientations, automatic algorithms to compensate the rotation were developed. Alternatively, a proper calibrat...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7764672/ https://www.ncbi.nlm.nih.gov/pubmed/33322387 http://dx.doi.org/10.3390/s20247107 |
_version_ | 1783628312217649152 |
---|---|
author | Bisogni, Livio Mollaiyan, Ramtin Pettinari, Matteo Neri, Paolo Gabiccini, Marco |
author_facet | Bisogni, Livio Mollaiyan, Ramtin Pettinari, Matteo Neri, Paolo Gabiccini, Marco |
author_sort | Bisogni, Livio |
collection | PubMed |
description | Rotary tables are often used to speed up the acquisition time during the 3D scanning of complex geometries. In order to avoid manual registration of the point clouds acquired with different orientations, automatic algorithms to compensate the rotation were developed. Alternatively, a proper calibration of the rotary axis with respect to the camera system is needed. Several methods are available in the literature, but they only consider a single-axis calibration. In this paper, a method for the simultaneous calibration of both axes of the table is proposed. A checkerboard is attached to the table, and several images with different poses are acquired. An optimization algorithm is then setup to determine the orientation and the locations of the two axes. A metric to assess the calibration quality was also defined by computing the average mean reprojection error. This metric is used to investigate the optimal number and distribution of the calibration poses, demonstrating that the optimum calibration results are achieved when a wider dispersion of the calibration poses is adopted. |
format | Online Article Text |
id | pubmed-7764672 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77646722020-12-27 Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes Bisogni, Livio Mollaiyan, Ramtin Pettinari, Matteo Neri, Paolo Gabiccini, Marco Sensors (Basel) Article Rotary tables are often used to speed up the acquisition time during the 3D scanning of complex geometries. In order to avoid manual registration of the point clouds acquired with different orientations, automatic algorithms to compensate the rotation were developed. Alternatively, a proper calibration of the rotary axis with respect to the camera system is needed. Several methods are available in the literature, but they only consider a single-axis calibration. In this paper, a method for the simultaneous calibration of both axes of the table is proposed. A checkerboard is attached to the table, and several images with different poses are acquired. An optimization algorithm is then setup to determine the orientation and the locations of the two axes. A metric to assess the calibration quality was also defined by computing the average mean reprojection error. This metric is used to investigate the optimal number and distribution of the calibration poses, demonstrating that the optimum calibration results are achieved when a wider dispersion of the calibration poses is adopted. MDPI 2020-12-11 /pmc/articles/PMC7764672/ /pubmed/33322387 http://dx.doi.org/10.3390/s20247107 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Bisogni, Livio Mollaiyan, Ramtin Pettinari, Matteo Neri, Paolo Gabiccini, Marco Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes |
title | Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes |
title_full | Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes |
title_fullStr | Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes |
title_full_unstemmed | Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes |
title_short | Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes |
title_sort | automatic calibration of a two-axis rotary table for 3d scanning purposes |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7764672/ https://www.ncbi.nlm.nih.gov/pubmed/33322387 http://dx.doi.org/10.3390/s20247107 |
work_keys_str_mv | AT bisognilivio automaticcalibrationofatwoaxisrotarytablefor3dscanningpurposes AT mollaiyanramtin automaticcalibrationofatwoaxisrotarytablefor3dscanningpurposes AT pettinarimatteo automaticcalibrationofatwoaxisrotarytablefor3dscanningpurposes AT neripaolo automaticcalibrationofatwoaxisrotarytablefor3dscanningpurposes AT gabiccinimarco automaticcalibrationofatwoaxisrotarytablefor3dscanningpurposes |