Cargando…

Dynamic Characteristics and Damage Detection of a Metallic Thermal Protection System Panel Using a Three-Dimensional Point Tracking Method and a Modal Assurance Criterion

A thermal protection system (TPS) is designed and fabricated to protect a hypersonic vehicle from extreme conditions. Good condition of the TPS panels is necessary for the next flight mission. A loose bolted joint is a crucial defect in a metallic TPS panel. This study introduces an experimental met...

Descripción completa

Detalles Bibliográficos
Autores principales: Le, Vinh Tung, Goo, Nam Seo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7765273/
https://www.ncbi.nlm.nih.gov/pubmed/33333880
http://dx.doi.org/10.3390/s20247185
_version_ 1783628453125292032
author Le, Vinh Tung
Goo, Nam Seo
author_facet Le, Vinh Tung
Goo, Nam Seo
author_sort Le, Vinh Tung
collection PubMed
description A thermal protection system (TPS) is designed and fabricated to protect a hypersonic vehicle from extreme conditions. Good condition of the TPS panels is necessary for the next flight mission. A loose bolted joint is a crucial defect in a metallic TPS panel. This study introduces an experimental method to investigate the dynamic characteristics and state of health of a metallic TPS panel through an operational modal analysis (OMA). Experimental investigations were implemented under free-free supports to account for a healthy state, the insulation effect, and fastener failures. The dynamic deformations resulted from an impulse force were measured using a non-contact three-dimensional point tracking (3DPT) method. Using changes in natural frequencies, the damping ratio, and operational deflection shapes (ODSs) due to the TPS failure, we were able to detect loose bolted joints. Moreover, we also developed an in-house program based on a modal assurance criterion (MAC) to detect the state of damage of test structures. In a damage state, such as a loose bolted joint, the stiffness of the TPS panel was reduced, which resulted in changes in the natural frequency and the damping ratio. The calculated MAC values were less than one, which pointed out possible damage in the test TPS panels. Our results also demonstrated that a combination of the 3DPT-based OMA method and the MAC achieved good robustness and sufficient accuracy in damage identification for complex aerospace structures such as TPS structures.
format Online
Article
Text
id pubmed-7765273
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77652732020-12-27 Dynamic Characteristics and Damage Detection of a Metallic Thermal Protection System Panel Using a Three-Dimensional Point Tracking Method and a Modal Assurance Criterion Le, Vinh Tung Goo, Nam Seo Sensors (Basel) Article A thermal protection system (TPS) is designed and fabricated to protect a hypersonic vehicle from extreme conditions. Good condition of the TPS panels is necessary for the next flight mission. A loose bolted joint is a crucial defect in a metallic TPS panel. This study introduces an experimental method to investigate the dynamic characteristics and state of health of a metallic TPS panel through an operational modal analysis (OMA). Experimental investigations were implemented under free-free supports to account for a healthy state, the insulation effect, and fastener failures. The dynamic deformations resulted from an impulse force were measured using a non-contact three-dimensional point tracking (3DPT) method. Using changes in natural frequencies, the damping ratio, and operational deflection shapes (ODSs) due to the TPS failure, we were able to detect loose bolted joints. Moreover, we also developed an in-house program based on a modal assurance criterion (MAC) to detect the state of damage of test structures. In a damage state, such as a loose bolted joint, the stiffness of the TPS panel was reduced, which resulted in changes in the natural frequency and the damping ratio. The calculated MAC values were less than one, which pointed out possible damage in the test TPS panels. Our results also demonstrated that a combination of the 3DPT-based OMA method and the MAC achieved good robustness and sufficient accuracy in damage identification for complex aerospace structures such as TPS structures. MDPI 2020-12-15 /pmc/articles/PMC7765273/ /pubmed/33333880 http://dx.doi.org/10.3390/s20247185 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Le, Vinh Tung
Goo, Nam Seo
Dynamic Characteristics and Damage Detection of a Metallic Thermal Protection System Panel Using a Three-Dimensional Point Tracking Method and a Modal Assurance Criterion
title Dynamic Characteristics and Damage Detection of a Metallic Thermal Protection System Panel Using a Three-Dimensional Point Tracking Method and a Modal Assurance Criterion
title_full Dynamic Characteristics and Damage Detection of a Metallic Thermal Protection System Panel Using a Three-Dimensional Point Tracking Method and a Modal Assurance Criterion
title_fullStr Dynamic Characteristics and Damage Detection of a Metallic Thermal Protection System Panel Using a Three-Dimensional Point Tracking Method and a Modal Assurance Criterion
title_full_unstemmed Dynamic Characteristics and Damage Detection of a Metallic Thermal Protection System Panel Using a Three-Dimensional Point Tracking Method and a Modal Assurance Criterion
title_short Dynamic Characteristics and Damage Detection of a Metallic Thermal Protection System Panel Using a Three-Dimensional Point Tracking Method and a Modal Assurance Criterion
title_sort dynamic characteristics and damage detection of a metallic thermal protection system panel using a three-dimensional point tracking method and a modal assurance criterion
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7765273/
https://www.ncbi.nlm.nih.gov/pubmed/33333880
http://dx.doi.org/10.3390/s20247185
work_keys_str_mv AT levinhtung dynamiccharacteristicsanddamagedetectionofametallicthermalprotectionsystempanelusingathreedimensionalpointtrackingmethodandamodalassurancecriterion
AT goonamseo dynamiccharacteristicsanddamagedetectionofametallicthermalprotectionsystempanelusingathreedimensionalpointtrackingmethodandamodalassurancecriterion