Cargando…
Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement
Air-coupled ultrasonic probes require a special design approach and handling due to the significant mismatch to the air. Outer matching layers have to be soft so can be easily damaged and excitation voltages might cause the degradation of electrodes or bonding between the layers. Integrity inspectio...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7765493/ https://www.ncbi.nlm.nih.gov/pubmed/33339095 http://dx.doi.org/10.3390/s20247196 |
_version_ | 1783628503056384000 |
---|---|
author | Svilainis, Linas Chaziachmetovas, Andrius Kybartas, Darius Gomez Alvarez-Arenas, Tomas |
author_facet | Svilainis, Linas Chaziachmetovas, Andrius Kybartas, Darius Gomez Alvarez-Arenas, Tomas |
author_sort | Svilainis, Linas |
collection | PubMed |
description | Air-coupled ultrasonic probes require a special design approach and handling due to the significant mismatch to the air. Outer matching layers have to be soft so can be easily damaged and excitation voltages might cause the degradation of electrodes or bonding between the layers. Integrity inspection is desired during design, manufacturing, and exploitation. Spatial distribution of a transduction efficiency over piezoelement surface is proposed as a convenient means for the air-coupled probe integrity inspection. Focused transducer of similar center frequency is used to scan the surface of the inspected probe. However, such approach creates a challenge, i.e., area of the scanning beam is much smaller than the total receiving area of the inspected probe, therefore, contrast and imaging resolution are significantly degraded. Masking aperture made from cardboard and felt, placed at the focal point was proposed as solution. Far-range sidelobes were suppressed down to the noise floor (−50 dB) and the near-range sidelobes were reduced down to −17 dB. The proposed modification allows to use a similar frequency focused transducer. Probe integrity inspection can be carried out at significantly enhanced contrast and lateral resolution. Natural and artificial defects can be detected by the use of the proposed method. |
format | Online Article Text |
id | pubmed-7765493 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77654932020-12-27 Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement Svilainis, Linas Chaziachmetovas, Andrius Kybartas, Darius Gomez Alvarez-Arenas, Tomas Sensors (Basel) Article Air-coupled ultrasonic probes require a special design approach and handling due to the significant mismatch to the air. Outer matching layers have to be soft so can be easily damaged and excitation voltages might cause the degradation of electrodes or bonding between the layers. Integrity inspection is desired during design, manufacturing, and exploitation. Spatial distribution of a transduction efficiency over piezoelement surface is proposed as a convenient means for the air-coupled probe integrity inspection. Focused transducer of similar center frequency is used to scan the surface of the inspected probe. However, such approach creates a challenge, i.e., area of the scanning beam is much smaller than the total receiving area of the inspected probe, therefore, contrast and imaging resolution are significantly degraded. Masking aperture made from cardboard and felt, placed at the focal point was proposed as solution. Far-range sidelobes were suppressed down to the noise floor (−50 dB) and the near-range sidelobes were reduced down to −17 dB. The proposed modification allows to use a similar frequency focused transducer. Probe integrity inspection can be carried out at significantly enhanced contrast and lateral resolution. Natural and artificial defects can be detected by the use of the proposed method. MDPI 2020-12-16 /pmc/articles/PMC7765493/ /pubmed/33339095 http://dx.doi.org/10.3390/s20247196 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Svilainis, Linas Chaziachmetovas, Andrius Kybartas, Darius Gomez Alvarez-Arenas, Tomas Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement |
title | Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement |
title_full | Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement |
title_fullStr | Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement |
title_full_unstemmed | Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement |
title_short | Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement |
title_sort | air-coupled ultrasonic probe integrity test using a focused transducer with similar frequency and limited aperture for contrast enhancement |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7765493/ https://www.ncbi.nlm.nih.gov/pubmed/33339095 http://dx.doi.org/10.3390/s20247196 |
work_keys_str_mv | AT svilainislinas aircoupledultrasonicprobeintegritytestusingafocusedtransducerwithsimilarfrequencyandlimitedapertureforcontrastenhancement AT chaziachmetovasandrius aircoupledultrasonicprobeintegritytestusingafocusedtransducerwithsimilarfrequencyandlimitedapertureforcontrastenhancement AT kybartasdarius aircoupledultrasonicprobeintegritytestusingafocusedtransducerwithsimilarfrequencyandlimitedapertureforcontrastenhancement AT gomezalvarezarenastomas aircoupledultrasonicprobeintegritytestusingafocusedtransducerwithsimilarfrequencyandlimitedapertureforcontrastenhancement |