Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement

Air-coupled ultrasonic probes require a special design approach and handling due to the significant mismatch to the air. Outer matching layers have to be soft so can be easily damaged and excitation voltages might cause the degradation of electrodes or bonding between the layers. Integrity inspectio...

Descripción completa

Detalles Bibliográficos
Autores principales: Svilainis, Linas, Chaziachmetovas, Andrius, Kybartas, Darius, Gomez Alvarez-Arenas, Tomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7765493/
https://www.ncbi.nlm.nih.gov/pubmed/33339095
http://dx.doi.org/10.3390/s20247196
_version_ 1783628503056384000
author Svilainis, Linas
Chaziachmetovas, Andrius
Kybartas, Darius
Gomez Alvarez-Arenas, Tomas
author_facet Svilainis, Linas
Chaziachmetovas, Andrius
Kybartas, Darius
Gomez Alvarez-Arenas, Tomas
author_sort Svilainis, Linas
collection PubMed
description Air-coupled ultrasonic probes require a special design approach and handling due to the significant mismatch to the air. Outer matching layers have to be soft so can be easily damaged and excitation voltages might cause the degradation of electrodes or bonding between the layers. Integrity inspection is desired during design, manufacturing, and exploitation. Spatial distribution of a transduction efficiency over piezoelement surface is proposed as a convenient means for the air-coupled probe integrity inspection. Focused transducer of similar center frequency is used to scan the surface of the inspected probe. However, such approach creates a challenge, i.e., area of the scanning beam is much smaller than the total receiving area of the inspected probe, therefore, contrast and imaging resolution are significantly degraded. Masking aperture made from cardboard and felt, placed at the focal point was proposed as solution. Far-range sidelobes were suppressed down to the noise floor (−50 dB) and the near-range sidelobes were reduced down to −17 dB. The proposed modification allows to use a similar frequency focused transducer. Probe integrity inspection can be carried out at significantly enhanced contrast and lateral resolution. Natural and artificial defects can be detected by the use of the proposed method.
format Online
Article
Text
id pubmed-7765493
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77654932020-12-27 Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement Svilainis, Linas Chaziachmetovas, Andrius Kybartas, Darius Gomez Alvarez-Arenas, Tomas Sensors (Basel) Article Air-coupled ultrasonic probes require a special design approach and handling due to the significant mismatch to the air. Outer matching layers have to be soft so can be easily damaged and excitation voltages might cause the degradation of electrodes or bonding between the layers. Integrity inspection is desired during design, manufacturing, and exploitation. Spatial distribution of a transduction efficiency over piezoelement surface is proposed as a convenient means for the air-coupled probe integrity inspection. Focused transducer of similar center frequency is used to scan the surface of the inspected probe. However, such approach creates a challenge, i.e., area of the scanning beam is much smaller than the total receiving area of the inspected probe, therefore, contrast and imaging resolution are significantly degraded. Masking aperture made from cardboard and felt, placed at the focal point was proposed as solution. Far-range sidelobes were suppressed down to the noise floor (−50 dB) and the near-range sidelobes were reduced down to −17 dB. The proposed modification allows to use a similar frequency focused transducer. Probe integrity inspection can be carried out at significantly enhanced contrast and lateral resolution. Natural and artificial defects can be detected by the use of the proposed method. MDPI 2020-12-16 /pmc/articles/PMC7765493/ /pubmed/33339095 http://dx.doi.org/10.3390/s20247196 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Svilainis, Linas
Chaziachmetovas, Andrius
Kybartas, Darius
Gomez Alvarez-Arenas, Tomas
Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement
title Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement
title_full Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement
title_fullStr Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement
title_full_unstemmed Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement
title_short Air-Coupled Ultrasonic Probe Integrity Test Using a Focused Transducer with Similar Frequency and Limited Aperture for Contrast Enhancement
title_sort air-coupled ultrasonic probe integrity test using a focused transducer with similar frequency and limited aperture for contrast enhancement
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7765493/
https://www.ncbi.nlm.nih.gov/pubmed/33339095
http://dx.doi.org/10.3390/s20247196
work_keys_str_mv AT svilainislinas aircoupledultrasonicprobeintegritytestusingafocusedtransducerwithsimilarfrequencyandlimitedapertureforcontrastenhancement
AT chaziachmetovasandrius aircoupledultrasonicprobeintegritytestusingafocusedtransducerwithsimilarfrequencyandlimitedapertureforcontrastenhancement
AT kybartasdarius aircoupledultrasonicprobeintegritytestusingafocusedtransducerwithsimilarfrequencyandlimitedapertureforcontrastenhancement
AT gomezalvarezarenastomas aircoupledultrasonicprobeintegritytestusingafocusedtransducerwithsimilarfrequencyandlimitedapertureforcontrastenhancement