Cargando…

Comparison of PRISMA Data with Model Simulations, Hyperion Reflectance and Field Spectrometer Measurements on ‘Piano delle Concazze’ (Mt. Etna, Italy)

In this work, we compare first acquisitions from the ASI-PRISMA (Agenzia Spaziale Italiana-PRecursore IperSpettrale della Missione Applicativa) space mission with model simulations, past data acquired by the Hyperion sensor and field spectrometer measurements. The test site is ‘Piano delle Concazze’...

Descripción completa

Detalles Bibliográficos
Autores principales: Romaniello, Vito, Silvestri, Malvina, Buongiorno, Maria Fabrizia, Musacchio, Massimo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7766377/
https://www.ncbi.nlm.nih.gov/pubmed/33348634
http://dx.doi.org/10.3390/s20247224
_version_ 1783628704129220608
author Romaniello, Vito
Silvestri, Malvina
Buongiorno, Maria Fabrizia
Musacchio, Massimo
author_facet Romaniello, Vito
Silvestri, Malvina
Buongiorno, Maria Fabrizia
Musacchio, Massimo
author_sort Romaniello, Vito
collection PubMed
description In this work, we compare first acquisitions from the ASI-PRISMA (Agenzia Spaziale Italiana-PRecursore IperSpettrale della Missione Applicativa) space mission with model simulations, past data acquired by the Hyperion sensor and field spectrometer measurements. The test site is ‘Piano delle Concazze’ (Mt. Etna, Italy), suitable for calibration purposes due to its homogeneity characteristics. The area measures at about 0.2 km(2) and is composed of very homogeneous trachybasalt rich in plagioclase and olivine. Three PRISMA acquisitions, achieved on 31 July and 8 and 17 August 2019, are analyzed. Firstly, spectral profiles of PRISMA top of atmosphere (TOA) radiance are compared with MODerate resolution atmospheric TRANsmission (MODTRAN) simulations. The Pearson correlation coefficient is equal to 0.998 and 0.994 for VNIR (Visible and Near InfraRed) and SWIR (Short-Wave InfraRed) spectral ranges, respectively. PRISMA radiance overestimates values simulated by MODTRAN for all considered days, showing a mean bias of +5.22 and of +0.91 Wm(−2)sr(−1)µm(−1) for VNIR and SWIR, respectively. The relative mean difference between reflectance values estimated by PRISMA and Hyperion, on the test area, is around +19%, despite the great difference in time acquisition (up to 19 years); PRISMA slightly overestimates Hyperion reflectance with an absolute mean difference of about +0.0083, within the variability of Hyperion acquisitions of ±0.0250 (corresponding to ±2 standard deviation). Finally, FieldSpec measurements also confirm the great quality of PRISMA reflectance estimations. The absolute mean difference results are around +0.0089 (corresponding to a relative error of about +21%). In the study, we investigate only the lower values of reflectance characterizing the test site. A more complete evaluation of PRISMA performances needs to consider other test sites with different optical characteristics.
format Online
Article
Text
id pubmed-7766377
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77663772020-12-28 Comparison of PRISMA Data with Model Simulations, Hyperion Reflectance and Field Spectrometer Measurements on ‘Piano delle Concazze’ (Mt. Etna, Italy) Romaniello, Vito Silvestri, Malvina Buongiorno, Maria Fabrizia Musacchio, Massimo Sensors (Basel) Letter In this work, we compare first acquisitions from the ASI-PRISMA (Agenzia Spaziale Italiana-PRecursore IperSpettrale della Missione Applicativa) space mission with model simulations, past data acquired by the Hyperion sensor and field spectrometer measurements. The test site is ‘Piano delle Concazze’ (Mt. Etna, Italy), suitable for calibration purposes due to its homogeneity characteristics. The area measures at about 0.2 km(2) and is composed of very homogeneous trachybasalt rich in plagioclase and olivine. Three PRISMA acquisitions, achieved on 31 July and 8 and 17 August 2019, are analyzed. Firstly, spectral profiles of PRISMA top of atmosphere (TOA) radiance are compared with MODerate resolution atmospheric TRANsmission (MODTRAN) simulations. The Pearson correlation coefficient is equal to 0.998 and 0.994 for VNIR (Visible and Near InfraRed) and SWIR (Short-Wave InfraRed) spectral ranges, respectively. PRISMA radiance overestimates values simulated by MODTRAN for all considered days, showing a mean bias of +5.22 and of +0.91 Wm(−2)sr(−1)µm(−1) for VNIR and SWIR, respectively. The relative mean difference between reflectance values estimated by PRISMA and Hyperion, on the test area, is around +19%, despite the great difference in time acquisition (up to 19 years); PRISMA slightly overestimates Hyperion reflectance with an absolute mean difference of about +0.0083, within the variability of Hyperion acquisitions of ±0.0250 (corresponding to ±2 standard deviation). Finally, FieldSpec measurements also confirm the great quality of PRISMA reflectance estimations. The absolute mean difference results are around +0.0089 (corresponding to a relative error of about +21%). In the study, we investigate only the lower values of reflectance characterizing the test site. A more complete evaluation of PRISMA performances needs to consider other test sites with different optical characteristics. MDPI 2020-12-17 /pmc/articles/PMC7766377/ /pubmed/33348634 http://dx.doi.org/10.3390/s20247224 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Letter
Romaniello, Vito
Silvestri, Malvina
Buongiorno, Maria Fabrizia
Musacchio, Massimo
Comparison of PRISMA Data with Model Simulations, Hyperion Reflectance and Field Spectrometer Measurements on ‘Piano delle Concazze’ (Mt. Etna, Italy)
title Comparison of PRISMA Data with Model Simulations, Hyperion Reflectance and Field Spectrometer Measurements on ‘Piano delle Concazze’ (Mt. Etna, Italy)
title_full Comparison of PRISMA Data with Model Simulations, Hyperion Reflectance and Field Spectrometer Measurements on ‘Piano delle Concazze’ (Mt. Etna, Italy)
title_fullStr Comparison of PRISMA Data with Model Simulations, Hyperion Reflectance and Field Spectrometer Measurements on ‘Piano delle Concazze’ (Mt. Etna, Italy)
title_full_unstemmed Comparison of PRISMA Data with Model Simulations, Hyperion Reflectance and Field Spectrometer Measurements on ‘Piano delle Concazze’ (Mt. Etna, Italy)
title_short Comparison of PRISMA Data with Model Simulations, Hyperion Reflectance and Field Spectrometer Measurements on ‘Piano delle Concazze’ (Mt. Etna, Italy)
title_sort comparison of prisma data with model simulations, hyperion reflectance and field spectrometer measurements on ‘piano delle concazze’ (mt. etna, italy)
topic Letter
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7766377/
https://www.ncbi.nlm.nih.gov/pubmed/33348634
http://dx.doi.org/10.3390/s20247224
work_keys_str_mv AT romaniellovito comparisonofprismadatawithmodelsimulationshyperionreflectanceandfieldspectrometermeasurementsonpianodelleconcazzemtetnaitaly
AT silvestrimalvina comparisonofprismadatawithmodelsimulationshyperionreflectanceandfieldspectrometermeasurementsonpianodelleconcazzemtetnaitaly
AT buongiornomariafabrizia comparisonofprismadatawithmodelsimulationshyperionreflectanceandfieldspectrometermeasurementsonpianodelleconcazzemtetnaitaly
AT musacchiomassimo comparisonofprismadatawithmodelsimulationshyperionreflectanceandfieldspectrometermeasurementsonpianodelleconcazzemtetnaitaly