Improved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement

Multilateration tracking systems (MLTSs) are used in industrial three-dimensional (3D) coordinate measuring applications. For high-precision measurement, system parameters must be calibrated properly in advance. For an MLTS using absolute distance measurement (ADM), the conventional self-calibration...

Descripción completa

Detalles Bibliográficos
Autores principales: Nguyen, Quoc Khanh, Kim, Seungman, Han, Seong-Heum, Ro, Seung-Kook, Kim, Seung-Woo, Kim, Young-Jin, Kim, Wooram, Oh, Jeong Seok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7766871/
https://www.ncbi.nlm.nih.gov/pubmed/33353042
http://dx.doi.org/10.3390/s20247288
_version_ 1783628822447390720
author Nguyen, Quoc Khanh
Kim, Seungman
Han, Seong-Heum
Ro, Seung-Kook
Kim, Seung-Woo
Kim, Young-Jin
Kim, Wooram
Oh, Jeong Seok
author_facet Nguyen, Quoc Khanh
Kim, Seungman
Han, Seong-Heum
Ro, Seung-Kook
Kim, Seung-Woo
Kim, Young-Jin
Kim, Wooram
Oh, Jeong Seok
author_sort Nguyen, Quoc Khanh
collection PubMed
description Multilateration tracking systems (MLTSs) are used in industrial three-dimensional (3D) coordinate measuring applications. For high-precision measurement, system parameters must be calibrated properly in advance. For an MLTS using absolute distance measurement (ADM), the conventional self-calibration method significantly reduces estimation efficiency because all system parameters are estimated simultaneously using a complicated residual function. This paper presents a novel self-calibration method that optimizes ADM to reduce the number of system parameters via highly precise and separate estimations of dead paths. Therefore, the residual function to estimate the tracking station locations can be simplified. By applying a suitable mathematical procedure and solving the initial guess problem without the aid of an external device, estimation accuracy of the system parameters is significantly improved. In three self-calibration experiments, with ADM repeatability of approximately 3.4 µm, the maximum deviation of the system parameters estimated by the proposed self-calibration method was 68.6 µm, while the maximum deviation estimated by the conventional self-calibration method was 711.9 µm. Validation of 3D coordinate measurements in a 1000 mm × 1000 mm × 1000 mm volume showed good agreement between the proposed ADM-based MLTS and a commercial laser tracker, where the maximum difference based on the standard deviation was 17.7 µm. Conversely, the maximum difference was 98.8 µm using the conventional self-calibration method. These results confirmed the efficiency and feasibility of the proposed self-calibration method.
format Online
Article
Text
id pubmed-7766871
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77668712020-12-28 Improved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement Nguyen, Quoc Khanh Kim, Seungman Han, Seong-Heum Ro, Seung-Kook Kim, Seung-Woo Kim, Young-Jin Kim, Wooram Oh, Jeong Seok Sensors (Basel) Article Multilateration tracking systems (MLTSs) are used in industrial three-dimensional (3D) coordinate measuring applications. For high-precision measurement, system parameters must be calibrated properly in advance. For an MLTS using absolute distance measurement (ADM), the conventional self-calibration method significantly reduces estimation efficiency because all system parameters are estimated simultaneously using a complicated residual function. This paper presents a novel self-calibration method that optimizes ADM to reduce the number of system parameters via highly precise and separate estimations of dead paths. Therefore, the residual function to estimate the tracking station locations can be simplified. By applying a suitable mathematical procedure and solving the initial guess problem without the aid of an external device, estimation accuracy of the system parameters is significantly improved. In three self-calibration experiments, with ADM repeatability of approximately 3.4 µm, the maximum deviation of the system parameters estimated by the proposed self-calibration method was 68.6 µm, while the maximum deviation estimated by the conventional self-calibration method was 711.9 µm. Validation of 3D coordinate measurements in a 1000 mm × 1000 mm × 1000 mm volume showed good agreement between the proposed ADM-based MLTS and a commercial laser tracker, where the maximum difference based on the standard deviation was 17.7 µm. Conversely, the maximum difference was 98.8 µm using the conventional self-calibration method. These results confirmed the efficiency and feasibility of the proposed self-calibration method. MDPI 2020-12-18 /pmc/articles/PMC7766871/ /pubmed/33353042 http://dx.doi.org/10.3390/s20247288 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Nguyen, Quoc Khanh
Kim, Seungman
Han, Seong-Heum
Ro, Seung-Kook
Kim, Seung-Woo
Kim, Young-Jin
Kim, Wooram
Oh, Jeong Seok
Improved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement
title Improved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement
title_full Improved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement
title_fullStr Improved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement
title_full_unstemmed Improved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement
title_short Improved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement
title_sort improved self-calibration of a multilateration system based on absolute distance measurement
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7766871/
https://www.ncbi.nlm.nih.gov/pubmed/33353042
http://dx.doi.org/10.3390/s20247288
work_keys_str_mv AT nguyenquockhanh improvedselfcalibrationofamultilaterationsystembasedonabsolutedistancemeasurement
AT kimseungman improvedselfcalibrationofamultilaterationsystembasedonabsolutedistancemeasurement
AT hanseongheum improvedselfcalibrationofamultilaterationsystembasedonabsolutedistancemeasurement
AT roseungkook improvedselfcalibrationofamultilaterationsystembasedonabsolutedistancemeasurement
AT kimseungwoo improvedselfcalibrationofamultilaterationsystembasedonabsolutedistancemeasurement
AT kimyoungjin improvedselfcalibrationofamultilaterationsystembasedonabsolutedistancemeasurement
AT kimwooram improvedselfcalibrationofamultilaterationsystembasedonabsolutedistancemeasurement
AT ohjeongseok improvedselfcalibrationofamultilaterationsystembasedonabsolutedistancemeasurement