Cargando…
Interrater Reliability of (99m)Tc-DMSA Scintigraphy Performed as Planar Scan vs. SPECT/Low Dose CT for Diagnosing Renal Scarring in Children
(99m)Tc-dimercaptosuccinic acid (DMSA) scintigraphy is currently the method of choice for assessing renal scarring in children, but it is not established whether conducting the scan as a single photon emission tomography combined with low-dose CT (SPECT/ldCT) scan provides additional diagnostic bene...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7766934/ https://www.ncbi.nlm.nih.gov/pubmed/33348530 http://dx.doi.org/10.3390/diagnostics10121101 |
_version_ | 1783628837423153152 |
---|---|
author | Einarsdóttir, Hrefna Sæunn Berg, Ronan Martin Griffin Borgwardt, Lise |
author_facet | Einarsdóttir, Hrefna Sæunn Berg, Ronan Martin Griffin Borgwardt, Lise |
author_sort | Einarsdóttir, Hrefna Sæunn |
collection | PubMed |
description | (99m)Tc-dimercaptosuccinic acid (DMSA) scintigraphy is currently the method of choice for assessing renal scarring in children, but it is not established whether conducting the scan as a single photon emission tomography combined with low-dose CT (SPECT/ldCT) scan provides additional diagnostic benefits when compared to conventional planar scintigraphy. In the present study, we evaluated the interrater reliability of DMSA SPECT/ldCT vs. planar DMSA scintigraphy for diagnosing renal scarring. Methods: Two nuclear medicine physicians blinded to patient data retrospectively analysed all paediatric (99m)Tc-DMSA scintigraphes that were conducted in our department for the assessment of post pyelonephritis renal scarring between 2011 and 2016. All scintigraphies included both a planar scan and SPECT/ldCT, and were performed on either a Phillips Precedence 16 slice CT or a Siemens Symbia 16 slice CT. The readers were blinded to each other’s readings and to patient data, and assessed all scans dichotomously for evidence of renal scarring. For each scan, the readers further noted if they were confident in their interpretation. Results: A total of 46 pairs of planar SPECT/ldCT DMSA scans were included. The readers were unconfident about their interpretation of 40% of the planar scans and 5% of the SPECT/ldCT scans. The interrater agreement rate was 72% for planar scans and 91% for SPECT/ldCT, and the corresponding Cohen’s kappa values were 0.38 and 0.79. Conclusion: DMSA SPECT/ldCT is associated with higher reader confidence and interrater reliability than conventional planar DMSA scintigraphy for the assessment of post pyelonephritis renal scarring in children. |
format | Online Article Text |
id | pubmed-7766934 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77669342020-12-28 Interrater Reliability of (99m)Tc-DMSA Scintigraphy Performed as Planar Scan vs. SPECT/Low Dose CT for Diagnosing Renal Scarring in Children Einarsdóttir, Hrefna Sæunn Berg, Ronan Martin Griffin Borgwardt, Lise Diagnostics (Basel) Communication (99m)Tc-dimercaptosuccinic acid (DMSA) scintigraphy is currently the method of choice for assessing renal scarring in children, but it is not established whether conducting the scan as a single photon emission tomography combined with low-dose CT (SPECT/ldCT) scan provides additional diagnostic benefits when compared to conventional planar scintigraphy. In the present study, we evaluated the interrater reliability of DMSA SPECT/ldCT vs. planar DMSA scintigraphy for diagnosing renal scarring. Methods: Two nuclear medicine physicians blinded to patient data retrospectively analysed all paediatric (99m)Tc-DMSA scintigraphes that were conducted in our department for the assessment of post pyelonephritis renal scarring between 2011 and 2016. All scintigraphies included both a planar scan and SPECT/ldCT, and were performed on either a Phillips Precedence 16 slice CT or a Siemens Symbia 16 slice CT. The readers were blinded to each other’s readings and to patient data, and assessed all scans dichotomously for evidence of renal scarring. For each scan, the readers further noted if they were confident in their interpretation. Results: A total of 46 pairs of planar SPECT/ldCT DMSA scans were included. The readers were unconfident about their interpretation of 40% of the planar scans and 5% of the SPECT/ldCT scans. The interrater agreement rate was 72% for planar scans and 91% for SPECT/ldCT, and the corresponding Cohen’s kappa values were 0.38 and 0.79. Conclusion: DMSA SPECT/ldCT is associated with higher reader confidence and interrater reliability than conventional planar DMSA scintigraphy for the assessment of post pyelonephritis renal scarring in children. MDPI 2020-12-17 /pmc/articles/PMC7766934/ /pubmed/33348530 http://dx.doi.org/10.3390/diagnostics10121101 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Communication Einarsdóttir, Hrefna Sæunn Berg, Ronan Martin Griffin Borgwardt, Lise Interrater Reliability of (99m)Tc-DMSA Scintigraphy Performed as Planar Scan vs. SPECT/Low Dose CT for Diagnosing Renal Scarring in Children |
title | Interrater Reliability of (99m)Tc-DMSA Scintigraphy Performed as Planar Scan vs. SPECT/Low Dose CT for Diagnosing Renal Scarring in Children |
title_full | Interrater Reliability of (99m)Tc-DMSA Scintigraphy Performed as Planar Scan vs. SPECT/Low Dose CT for Diagnosing Renal Scarring in Children |
title_fullStr | Interrater Reliability of (99m)Tc-DMSA Scintigraphy Performed as Planar Scan vs. SPECT/Low Dose CT for Diagnosing Renal Scarring in Children |
title_full_unstemmed | Interrater Reliability of (99m)Tc-DMSA Scintigraphy Performed as Planar Scan vs. SPECT/Low Dose CT for Diagnosing Renal Scarring in Children |
title_short | Interrater Reliability of (99m)Tc-DMSA Scintigraphy Performed as Planar Scan vs. SPECT/Low Dose CT for Diagnosing Renal Scarring in Children |
title_sort | interrater reliability of (99m)tc-dmsa scintigraphy performed as planar scan vs. spect/low dose ct for diagnosing renal scarring in children |
topic | Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7766934/ https://www.ncbi.nlm.nih.gov/pubmed/33348530 http://dx.doi.org/10.3390/diagnostics10121101 |
work_keys_str_mv | AT einarsdottirhrefnasæunn interraterreliabilityof99mtcdmsascintigraphyperformedasplanarscanvsspectlowdosectfordiagnosingrenalscarringinchildren AT bergronanmartingriffin interraterreliabilityof99mtcdmsascintigraphyperformedasplanarscanvsspectlowdosectfordiagnosingrenalscarringinchildren AT borgwardtlise interraterreliabilityof99mtcdmsascintigraphyperformedasplanarscanvsspectlowdosectfordiagnosingrenalscarringinchildren |