Comparison of Low-Cost Particulate Matter Sensors for Indoor Air Monitoring during COVID-19 Lockdown
This study shows the results of air monitoring in high- and low-occupancy rooms using two combinations of sensors, AeroTrak8220(TSI)/OPC-N3 (AlphaSense, Great Notley, UK) and OPC-N3/PMS5003 (Plantower, Beijing, China), respectively. The tests were conducted in a flat in Warsaw during the restriction...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7766947/ https://www.ncbi.nlm.nih.gov/pubmed/33353048 http://dx.doi.org/10.3390/s20247290 |
_version_ | 1783628840517500928 |
---|---|
author | Kaliszewski, Miron Włodarski, Maksymilian Młyńczak, Jarosław Kopczyński, Krzysztof |
author_facet | Kaliszewski, Miron Włodarski, Maksymilian Młyńczak, Jarosław Kopczyński, Krzysztof |
author_sort | Kaliszewski, Miron |
collection | PubMed |
description | This study shows the results of air monitoring in high- and low-occupancy rooms using two combinations of sensors, AeroTrak8220(TSI)/OPC-N3 (AlphaSense, Great Notley, UK) and OPC-N3/PMS5003 (Plantower, Beijing, China), respectively. The tests were conducted in a flat in Warsaw during the restrictions imposed due to the COVID-19 lockdown. The results showed that OPC-N3 underestimates the PN (particle number concentration) by about 2–3 times compared to the AeroTrak8220. Subsequently, the OPC-N3 was compared with another low-cost sensor, the PMS5003. Both devices showed similar efficiency in PN estimation, whereas PM (particulate matter) concentration estimation differed significantly. Moreover, the relationship among the PM(1)–PM(2.5)–PM(10) readings obtained with the PMS5003 appeared improbably linear regarding the natural indoor conditions. The correlation of PM concentrations obtained with the PMS5003 suggests an oversimplified calculation method of PM. The studies also demonstrated that PM(1), PM(2.5), and PM(10) concentrations in the high- to low-occupancy rooms were about 3, 2, and 1.5 times, respectively. On the other hand, the use of an air purifier considerably reduced the PM concentrations to similar levels in both rooms. All the sensors showed that frying and toast-making were the major sources of particulate matter, about 10 times higher compared to average levels. Considerably lower particle levels were measured in the low-occupancy room. |
format | Online Article Text |
id | pubmed-7766947 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77669472020-12-28 Comparison of Low-Cost Particulate Matter Sensors for Indoor Air Monitoring during COVID-19 Lockdown Kaliszewski, Miron Włodarski, Maksymilian Młyńczak, Jarosław Kopczyński, Krzysztof Sensors (Basel) Article This study shows the results of air monitoring in high- and low-occupancy rooms using two combinations of sensors, AeroTrak8220(TSI)/OPC-N3 (AlphaSense, Great Notley, UK) and OPC-N3/PMS5003 (Plantower, Beijing, China), respectively. The tests were conducted in a flat in Warsaw during the restrictions imposed due to the COVID-19 lockdown. The results showed that OPC-N3 underestimates the PN (particle number concentration) by about 2–3 times compared to the AeroTrak8220. Subsequently, the OPC-N3 was compared with another low-cost sensor, the PMS5003. Both devices showed similar efficiency in PN estimation, whereas PM (particulate matter) concentration estimation differed significantly. Moreover, the relationship among the PM(1)–PM(2.5)–PM(10) readings obtained with the PMS5003 appeared improbably linear regarding the natural indoor conditions. The correlation of PM concentrations obtained with the PMS5003 suggests an oversimplified calculation method of PM. The studies also demonstrated that PM(1), PM(2.5), and PM(10) concentrations in the high- to low-occupancy rooms were about 3, 2, and 1.5 times, respectively. On the other hand, the use of an air purifier considerably reduced the PM concentrations to similar levels in both rooms. All the sensors showed that frying and toast-making were the major sources of particulate matter, about 10 times higher compared to average levels. Considerably lower particle levels were measured in the low-occupancy room. MDPI 2020-12-18 /pmc/articles/PMC7766947/ /pubmed/33353048 http://dx.doi.org/10.3390/s20247290 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kaliszewski, Miron Włodarski, Maksymilian Młyńczak, Jarosław Kopczyński, Krzysztof Comparison of Low-Cost Particulate Matter Sensors for Indoor Air Monitoring during COVID-19 Lockdown |
title | Comparison of Low-Cost Particulate Matter Sensors for Indoor Air Monitoring during COVID-19 Lockdown |
title_full | Comparison of Low-Cost Particulate Matter Sensors for Indoor Air Monitoring during COVID-19 Lockdown |
title_fullStr | Comparison of Low-Cost Particulate Matter Sensors for Indoor Air Monitoring during COVID-19 Lockdown |
title_full_unstemmed | Comparison of Low-Cost Particulate Matter Sensors for Indoor Air Monitoring during COVID-19 Lockdown |
title_short | Comparison of Low-Cost Particulate Matter Sensors for Indoor Air Monitoring during COVID-19 Lockdown |
title_sort | comparison of low-cost particulate matter sensors for indoor air monitoring during covid-19 lockdown |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7766947/ https://www.ncbi.nlm.nih.gov/pubmed/33353048 http://dx.doi.org/10.3390/s20247290 |
work_keys_str_mv | AT kaliszewskimiron comparisonoflowcostparticulatemattersensorsforindoorairmonitoringduringcovid19lockdown AT włodarskimaksymilian comparisonoflowcostparticulatemattersensorsforindoorairmonitoringduringcovid19lockdown AT młynczakjarosław comparisonoflowcostparticulatemattersensorsforindoorairmonitoringduringcovid19lockdown AT kopczynskikrzysztof comparisonoflowcostparticulatemattersensorsforindoorairmonitoringduringcovid19lockdown |