Cargando…

A Lipid-Bilayer-On-A-Cup Device for Pumpless Sample Exchange

Lipid-bilayer devices have been studied for on-site sensors in the fields of diagnosis, food and environmental monitoring, and safety/security inspection. In this paper, we propose a lipid-bilayer-on-a-cup device for serial sample measurements using a pumpless solution exchange procedure. The device...

Descripción completa

Detalles Bibliográficos
Autores principales: Ito, Yoshihisa, Izawa, Yusuke, Osaki, Toshihisa, Kamiya, Koki, Misawa, Nobuo, Fujii, Satoshi, Mimura, Hisatoshi, Miki, Norihisa, Takeuchi, Shoji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7767076/
https://www.ncbi.nlm.nih.gov/pubmed/33352964
http://dx.doi.org/10.3390/mi11121123
_version_ 1783628871414841344
author Ito, Yoshihisa
Izawa, Yusuke
Osaki, Toshihisa
Kamiya, Koki
Misawa, Nobuo
Fujii, Satoshi
Mimura, Hisatoshi
Miki, Norihisa
Takeuchi, Shoji
author_facet Ito, Yoshihisa
Izawa, Yusuke
Osaki, Toshihisa
Kamiya, Koki
Misawa, Nobuo
Fujii, Satoshi
Mimura, Hisatoshi
Miki, Norihisa
Takeuchi, Shoji
author_sort Ito, Yoshihisa
collection PubMed
description Lipid-bilayer devices have been studied for on-site sensors in the fields of diagnosis, food and environmental monitoring, and safety/security inspection. In this paper, we propose a lipid-bilayer-on-a-cup device for serial sample measurements using a pumpless solution exchange procedure. The device consists of a millimeter-scale cylindrical cup with vertical slits which is designed to steadily hold an aqueous solution and exchange the sample by simply fusing and splitting the solution with an external solution. The slit design was experimentally determined by the capabilities of both the retention and exchange of the solution. Using the optimized slit, a planar lipid bilayer was reconstituted with a nanopore protein at a microaperture allocated to the bottom of the cup, and the device was connected to a portable amplifier. The solution exchangeability was demonstrated by observing the dilution process of a blocker molecule of the nanopore dissolved in the cup. The pumpless solution exchange by the proposed cup-like device presents potential as a lipid-bilayer system for portable sensing applications.
format Online
Article
Text
id pubmed-7767076
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77670762020-12-28 A Lipid-Bilayer-On-A-Cup Device for Pumpless Sample Exchange Ito, Yoshihisa Izawa, Yusuke Osaki, Toshihisa Kamiya, Koki Misawa, Nobuo Fujii, Satoshi Mimura, Hisatoshi Miki, Norihisa Takeuchi, Shoji Micromachines (Basel) Article Lipid-bilayer devices have been studied for on-site sensors in the fields of diagnosis, food and environmental monitoring, and safety/security inspection. In this paper, we propose a lipid-bilayer-on-a-cup device for serial sample measurements using a pumpless solution exchange procedure. The device consists of a millimeter-scale cylindrical cup with vertical slits which is designed to steadily hold an aqueous solution and exchange the sample by simply fusing and splitting the solution with an external solution. The slit design was experimentally determined by the capabilities of both the retention and exchange of the solution. Using the optimized slit, a planar lipid bilayer was reconstituted with a nanopore protein at a microaperture allocated to the bottom of the cup, and the device was connected to a portable amplifier. The solution exchangeability was demonstrated by observing the dilution process of a blocker molecule of the nanopore dissolved in the cup. The pumpless solution exchange by the proposed cup-like device presents potential as a lipid-bilayer system for portable sensing applications. MDPI 2020-12-18 /pmc/articles/PMC7767076/ /pubmed/33352964 http://dx.doi.org/10.3390/mi11121123 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ito, Yoshihisa
Izawa, Yusuke
Osaki, Toshihisa
Kamiya, Koki
Misawa, Nobuo
Fujii, Satoshi
Mimura, Hisatoshi
Miki, Norihisa
Takeuchi, Shoji
A Lipid-Bilayer-On-A-Cup Device for Pumpless Sample Exchange
title A Lipid-Bilayer-On-A-Cup Device for Pumpless Sample Exchange
title_full A Lipid-Bilayer-On-A-Cup Device for Pumpless Sample Exchange
title_fullStr A Lipid-Bilayer-On-A-Cup Device for Pumpless Sample Exchange
title_full_unstemmed A Lipid-Bilayer-On-A-Cup Device for Pumpless Sample Exchange
title_short A Lipid-Bilayer-On-A-Cup Device for Pumpless Sample Exchange
title_sort lipid-bilayer-on-a-cup device for pumpless sample exchange
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7767076/
https://www.ncbi.nlm.nih.gov/pubmed/33352964
http://dx.doi.org/10.3390/mi11121123
work_keys_str_mv AT itoyoshihisa alipidbilayeronacupdeviceforpumplesssampleexchange
AT izawayusuke alipidbilayeronacupdeviceforpumplesssampleexchange
AT osakitoshihisa alipidbilayeronacupdeviceforpumplesssampleexchange
AT kamiyakoki alipidbilayeronacupdeviceforpumplesssampleexchange
AT misawanobuo alipidbilayeronacupdeviceforpumplesssampleexchange
AT fujiisatoshi alipidbilayeronacupdeviceforpumplesssampleexchange
AT mimurahisatoshi alipidbilayeronacupdeviceforpumplesssampleexchange
AT mikinorihisa alipidbilayeronacupdeviceforpumplesssampleexchange
AT takeuchishoji alipidbilayeronacupdeviceforpumplesssampleexchange
AT itoyoshihisa lipidbilayeronacupdeviceforpumplesssampleexchange
AT izawayusuke lipidbilayeronacupdeviceforpumplesssampleexchange
AT osakitoshihisa lipidbilayeronacupdeviceforpumplesssampleexchange
AT kamiyakoki lipidbilayeronacupdeviceforpumplesssampleexchange
AT misawanobuo lipidbilayeronacupdeviceforpumplesssampleexchange
AT fujiisatoshi lipidbilayeronacupdeviceforpumplesssampleexchange
AT mimurahisatoshi lipidbilayeronacupdeviceforpumplesssampleexchange
AT mikinorihisa lipidbilayeronacupdeviceforpumplesssampleexchange
AT takeuchishoji lipidbilayeronacupdeviceforpumplesssampleexchange