Cargando…
A Lipid-Bilayer-On-A-Cup Device for Pumpless Sample Exchange
Lipid-bilayer devices have been studied for on-site sensors in the fields of diagnosis, food and environmental monitoring, and safety/security inspection. In this paper, we propose a lipid-bilayer-on-a-cup device for serial sample measurements using a pumpless solution exchange procedure. The device...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7767076/ https://www.ncbi.nlm.nih.gov/pubmed/33352964 http://dx.doi.org/10.3390/mi11121123 |
_version_ | 1783628871414841344 |
---|---|
author | Ito, Yoshihisa Izawa, Yusuke Osaki, Toshihisa Kamiya, Koki Misawa, Nobuo Fujii, Satoshi Mimura, Hisatoshi Miki, Norihisa Takeuchi, Shoji |
author_facet | Ito, Yoshihisa Izawa, Yusuke Osaki, Toshihisa Kamiya, Koki Misawa, Nobuo Fujii, Satoshi Mimura, Hisatoshi Miki, Norihisa Takeuchi, Shoji |
author_sort | Ito, Yoshihisa |
collection | PubMed |
description | Lipid-bilayer devices have been studied for on-site sensors in the fields of diagnosis, food and environmental monitoring, and safety/security inspection. In this paper, we propose a lipid-bilayer-on-a-cup device for serial sample measurements using a pumpless solution exchange procedure. The device consists of a millimeter-scale cylindrical cup with vertical slits which is designed to steadily hold an aqueous solution and exchange the sample by simply fusing and splitting the solution with an external solution. The slit design was experimentally determined by the capabilities of both the retention and exchange of the solution. Using the optimized slit, a planar lipid bilayer was reconstituted with a nanopore protein at a microaperture allocated to the bottom of the cup, and the device was connected to a portable amplifier. The solution exchangeability was demonstrated by observing the dilution process of a blocker molecule of the nanopore dissolved in the cup. The pumpless solution exchange by the proposed cup-like device presents potential as a lipid-bilayer system for portable sensing applications. |
format | Online Article Text |
id | pubmed-7767076 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77670762020-12-28 A Lipid-Bilayer-On-A-Cup Device for Pumpless Sample Exchange Ito, Yoshihisa Izawa, Yusuke Osaki, Toshihisa Kamiya, Koki Misawa, Nobuo Fujii, Satoshi Mimura, Hisatoshi Miki, Norihisa Takeuchi, Shoji Micromachines (Basel) Article Lipid-bilayer devices have been studied for on-site sensors in the fields of diagnosis, food and environmental monitoring, and safety/security inspection. In this paper, we propose a lipid-bilayer-on-a-cup device for serial sample measurements using a pumpless solution exchange procedure. The device consists of a millimeter-scale cylindrical cup with vertical slits which is designed to steadily hold an aqueous solution and exchange the sample by simply fusing and splitting the solution with an external solution. The slit design was experimentally determined by the capabilities of both the retention and exchange of the solution. Using the optimized slit, a planar lipid bilayer was reconstituted with a nanopore protein at a microaperture allocated to the bottom of the cup, and the device was connected to a portable amplifier. The solution exchangeability was demonstrated by observing the dilution process of a blocker molecule of the nanopore dissolved in the cup. The pumpless solution exchange by the proposed cup-like device presents potential as a lipid-bilayer system for portable sensing applications. MDPI 2020-12-18 /pmc/articles/PMC7767076/ /pubmed/33352964 http://dx.doi.org/10.3390/mi11121123 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ito, Yoshihisa Izawa, Yusuke Osaki, Toshihisa Kamiya, Koki Misawa, Nobuo Fujii, Satoshi Mimura, Hisatoshi Miki, Norihisa Takeuchi, Shoji A Lipid-Bilayer-On-A-Cup Device for Pumpless Sample Exchange |
title | A Lipid-Bilayer-On-A-Cup Device for Pumpless Sample Exchange |
title_full | A Lipid-Bilayer-On-A-Cup Device for Pumpless Sample Exchange |
title_fullStr | A Lipid-Bilayer-On-A-Cup Device for Pumpless Sample Exchange |
title_full_unstemmed | A Lipid-Bilayer-On-A-Cup Device for Pumpless Sample Exchange |
title_short | A Lipid-Bilayer-On-A-Cup Device for Pumpless Sample Exchange |
title_sort | lipid-bilayer-on-a-cup device for pumpless sample exchange |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7767076/ https://www.ncbi.nlm.nih.gov/pubmed/33352964 http://dx.doi.org/10.3390/mi11121123 |
work_keys_str_mv | AT itoyoshihisa alipidbilayeronacupdeviceforpumplesssampleexchange AT izawayusuke alipidbilayeronacupdeviceforpumplesssampleexchange AT osakitoshihisa alipidbilayeronacupdeviceforpumplesssampleexchange AT kamiyakoki alipidbilayeronacupdeviceforpumplesssampleexchange AT misawanobuo alipidbilayeronacupdeviceforpumplesssampleexchange AT fujiisatoshi alipidbilayeronacupdeviceforpumplesssampleexchange AT mimurahisatoshi alipidbilayeronacupdeviceforpumplesssampleexchange AT mikinorihisa alipidbilayeronacupdeviceforpumplesssampleexchange AT takeuchishoji alipidbilayeronacupdeviceforpumplesssampleexchange AT itoyoshihisa lipidbilayeronacupdeviceforpumplesssampleexchange AT izawayusuke lipidbilayeronacupdeviceforpumplesssampleexchange AT osakitoshihisa lipidbilayeronacupdeviceforpumplesssampleexchange AT kamiyakoki lipidbilayeronacupdeviceforpumplesssampleexchange AT misawanobuo lipidbilayeronacupdeviceforpumplesssampleexchange AT fujiisatoshi lipidbilayeronacupdeviceforpumplesssampleexchange AT mimurahisatoshi lipidbilayeronacupdeviceforpumplesssampleexchange AT mikinorihisa lipidbilayeronacupdeviceforpumplesssampleexchange AT takeuchishoji lipidbilayeronacupdeviceforpumplesssampleexchange |