Cargando…

Correlation between Preoperative Coronary Artery Stenosis Severity Measured by Instantaneous Wave-Free Ratio and Intraoperative Transit Time Flow Measurement of Attached Grafts

Background and Objectives: To assess the correlation between the degree of target coronary artery stenosis measured by instantaneous wave-free ratio (iFR) and the intraoperative transit time flow measurement (TTFM) of attached grafts as well as evaluate flow competition between the native coronary a...

Descripción completa

Detalles Bibliográficos
Autores principales: Tolegenuly, Almas, Ordiene, Rasa, Mamedov, Arslan, Unikas, Ramunas, Benetis, Rimantas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7767172/
https://www.ncbi.nlm.nih.gov/pubmed/33353214
http://dx.doi.org/10.3390/medicina56120714
_version_ 1783628893472686080
author Tolegenuly, Almas
Ordiene, Rasa
Mamedov, Arslan
Unikas, Ramunas
Benetis, Rimantas
author_facet Tolegenuly, Almas
Ordiene, Rasa
Mamedov, Arslan
Unikas, Ramunas
Benetis, Rimantas
author_sort Tolegenuly, Almas
collection PubMed
description Background and Objectives: To assess the correlation between the degree of target coronary artery stenosis measured by instantaneous wave-free ratio (iFR) and the intraoperative transit time flow measurement (TTFM) of attached grafts as well as evaluate flow competition between the native coronary artery and the attached graft according to the severity of stenosis. Materials and Methods: In total, 89 grafts were subjected to intraoperative transit time flow measurement after coronary artery bypass grafting (CABG) in 25 patients with multivessel coronary artery disease (CAD). The iFR was evaluated for all coronary arteries with grafts. The coronary artery stenoses were divided into three groups based on the iFR value: iFR < 0.86 (group 1); iFR 0.86–0.90 (group 2); and iFR > 0.90 (group 3). Results: The mean graft flow (MGF) was 46.9 ± 18.4 mL/min for group 1, 45.3 ± 20.9 mL/min for group 2, and 31.3 ± 18.5 mL/min for group 3. A statistically significant difference was confirmed between groups 1 and 3 (p = 0.002) and between groups 2 and 3 (p = 0.025). The pulsatility index (PI) was 2.49 ± 1.20 for group 1, 2.66 ± 2.13 for group 2, and 4.70 ± 3.66 for group 3. A statistically significant difference was found between groups 1 and 3 (p = 0.006) and between groups 2 and 3 (p = 0.032). Backward flow was detected in 7.5% of grafts for group 1, in 16.6% of grafts for group 2, and in 16% of grafts for group 3. A statistically significant difference was found between groups 1 and 2 (p = 0.025) and between groups 1 and 3 (p = 0.029). Conclusions: The iFR is a useful tool for predicting the impact of competitive flow observed between a native artery and an attached graft. The effect of competitive flow significantly increases when the graft is attached to a vessel with mild coronary stenosis. In a coronary artery where the iFR was not hemodynamically significant, the MGF was lower, the PI was higher, and a larger proportion of grafts with backward flow (BF) was detected compared to when there was significant stenosis (iFR < 0.86).
format Online
Article
Text
id pubmed-7767172
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77671722020-12-28 Correlation between Preoperative Coronary Artery Stenosis Severity Measured by Instantaneous Wave-Free Ratio and Intraoperative Transit Time Flow Measurement of Attached Grafts Tolegenuly, Almas Ordiene, Rasa Mamedov, Arslan Unikas, Ramunas Benetis, Rimantas Medicina (Kaunas) Article Background and Objectives: To assess the correlation between the degree of target coronary artery stenosis measured by instantaneous wave-free ratio (iFR) and the intraoperative transit time flow measurement (TTFM) of attached grafts as well as evaluate flow competition between the native coronary artery and the attached graft according to the severity of stenosis. Materials and Methods: In total, 89 grafts were subjected to intraoperative transit time flow measurement after coronary artery bypass grafting (CABG) in 25 patients with multivessel coronary artery disease (CAD). The iFR was evaluated for all coronary arteries with grafts. The coronary artery stenoses were divided into three groups based on the iFR value: iFR < 0.86 (group 1); iFR 0.86–0.90 (group 2); and iFR > 0.90 (group 3). Results: The mean graft flow (MGF) was 46.9 ± 18.4 mL/min for group 1, 45.3 ± 20.9 mL/min for group 2, and 31.3 ± 18.5 mL/min for group 3. A statistically significant difference was confirmed between groups 1 and 3 (p = 0.002) and between groups 2 and 3 (p = 0.025). The pulsatility index (PI) was 2.49 ± 1.20 for group 1, 2.66 ± 2.13 for group 2, and 4.70 ± 3.66 for group 3. A statistically significant difference was found between groups 1 and 3 (p = 0.006) and between groups 2 and 3 (p = 0.032). Backward flow was detected in 7.5% of grafts for group 1, in 16.6% of grafts for group 2, and in 16% of grafts for group 3. A statistically significant difference was found between groups 1 and 2 (p = 0.025) and between groups 1 and 3 (p = 0.029). Conclusions: The iFR is a useful tool for predicting the impact of competitive flow observed between a native artery and an attached graft. The effect of competitive flow significantly increases when the graft is attached to a vessel with mild coronary stenosis. In a coronary artery where the iFR was not hemodynamically significant, the MGF was lower, the PI was higher, and a larger proportion of grafts with backward flow (BF) was detected compared to when there was significant stenosis (iFR < 0.86). MDPI 2020-12-18 /pmc/articles/PMC7767172/ /pubmed/33353214 http://dx.doi.org/10.3390/medicina56120714 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Tolegenuly, Almas
Ordiene, Rasa
Mamedov, Arslan
Unikas, Ramunas
Benetis, Rimantas
Correlation between Preoperative Coronary Artery Stenosis Severity Measured by Instantaneous Wave-Free Ratio and Intraoperative Transit Time Flow Measurement of Attached Grafts
title Correlation between Preoperative Coronary Artery Stenosis Severity Measured by Instantaneous Wave-Free Ratio and Intraoperative Transit Time Flow Measurement of Attached Grafts
title_full Correlation between Preoperative Coronary Artery Stenosis Severity Measured by Instantaneous Wave-Free Ratio and Intraoperative Transit Time Flow Measurement of Attached Grafts
title_fullStr Correlation between Preoperative Coronary Artery Stenosis Severity Measured by Instantaneous Wave-Free Ratio and Intraoperative Transit Time Flow Measurement of Attached Grafts
title_full_unstemmed Correlation between Preoperative Coronary Artery Stenosis Severity Measured by Instantaneous Wave-Free Ratio and Intraoperative Transit Time Flow Measurement of Attached Grafts
title_short Correlation between Preoperative Coronary Artery Stenosis Severity Measured by Instantaneous Wave-Free Ratio and Intraoperative Transit Time Flow Measurement of Attached Grafts
title_sort correlation between preoperative coronary artery stenosis severity measured by instantaneous wave-free ratio and intraoperative transit time flow measurement of attached grafts
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7767172/
https://www.ncbi.nlm.nih.gov/pubmed/33353214
http://dx.doi.org/10.3390/medicina56120714
work_keys_str_mv AT tolegenulyalmas correlationbetweenpreoperativecoronaryarterystenosisseveritymeasuredbyinstantaneouswavefreeratioandintraoperativetransittimeflowmeasurementofattachedgrafts
AT ordienerasa correlationbetweenpreoperativecoronaryarterystenosisseveritymeasuredbyinstantaneouswavefreeratioandintraoperativetransittimeflowmeasurementofattachedgrafts
AT mamedovarslan correlationbetweenpreoperativecoronaryarterystenosisseveritymeasuredbyinstantaneouswavefreeratioandintraoperativetransittimeflowmeasurementofattachedgrafts
AT unikasramunas correlationbetweenpreoperativecoronaryarterystenosisseveritymeasuredbyinstantaneouswavefreeratioandintraoperativetransittimeflowmeasurementofattachedgrafts
AT benetisrimantas correlationbetweenpreoperativecoronaryarterystenosisseveritymeasuredbyinstantaneouswavefreeratioandintraoperativetransittimeflowmeasurementofattachedgrafts