Cargando…

Design Reliable Bus Structure Distributed Fiber Bragg Grating Sensor Network Using Gated Recurrent Unit Network

The focus of this paper was designing and demonstrating bus structure FBG sensor networks using intensity wavelength division multiplexing (IWDM) techniques and a gated recurrent unit (GRU) algorithm to increase the capability of multiplexing and the ability to detect Bragg wavelengths with greater...

Descripción completa

Detalles Bibliográficos
Autores principales: Dehnaw, Amare Mulatie, Manie, Yibeltal Chanie, Chen, Ya Yu, Chiu, Po Han, Huang, Hung Wei, Chen, Guan Wei, Peng, Peng Chun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7767492/
https://www.ncbi.nlm.nih.gov/pubmed/33371509
http://dx.doi.org/10.3390/s20247355
_version_ 1783628971590549504
author Dehnaw, Amare Mulatie
Manie, Yibeltal Chanie
Chen, Ya Yu
Chiu, Po Han
Huang, Hung Wei
Chen, Guan Wei
Peng, Peng Chun
author_facet Dehnaw, Amare Mulatie
Manie, Yibeltal Chanie
Chen, Ya Yu
Chiu, Po Han
Huang, Hung Wei
Chen, Guan Wei
Peng, Peng Chun
author_sort Dehnaw, Amare Mulatie
collection PubMed
description The focus of this paper was designing and demonstrating bus structure FBG sensor networks using intensity wavelength division multiplexing (IWDM) techniques and a gated recurrent unit (GRU) algorithm to increase the capability of multiplexing and the ability to detect Bragg wavelengths with greater accuracy. Several Fiber Bragg grating (FBG) sensors are coupled with power ratios of 90:10 and 80:10, respectively in the suggested experimental setup. We used the latest IWDM multiplexing technique for the proposed scheme, as the IWDM system increases the number of sensors and allows us to alleviate the limited operational region drawback of conventional wavelength division multiplexing (WDM). However, IWDM has a crosstalk problem that causes high-sensor signal measurement errors. Thus, we proposed the GRU model to overcome this crosstalk or overlapping problem by converting the spectral detection problem into a regression problem and considered the sequence of spectral features as input. By feeding this sequential spectrum dataset into the GRU model, we trained the GRU system until we achieved optimal efficiency. Consequently, the well-trained GRU model quickly and accurately identifies the Bragg wavelength of each FBG from the overlapping spectra. The Bragg wavelength detection performance of our proposed GRU model is tested or validated using different numbers of FBG sensors, such as 3-FBG, 5-FBG, 7-FBG, and 10-FBG, separately. As a result, the experiment result proves that the well-trained GRU model accurately identifies each FBG Bragg wavelength, and even the number of FBG sensors increase, as well as the spectra of FBGs, which are partially or fully overlapped. Therefore, to boost the detection efficiency, reliability, and to increase the multiplexing capabilities of FBG sensor networks, the proposed sensor system is better than the other previously proposed methods.
format Online
Article
Text
id pubmed-7767492
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77674922020-12-28 Design Reliable Bus Structure Distributed Fiber Bragg Grating Sensor Network Using Gated Recurrent Unit Network Dehnaw, Amare Mulatie Manie, Yibeltal Chanie Chen, Ya Yu Chiu, Po Han Huang, Hung Wei Chen, Guan Wei Peng, Peng Chun Sensors (Basel) Article The focus of this paper was designing and demonstrating bus structure FBG sensor networks using intensity wavelength division multiplexing (IWDM) techniques and a gated recurrent unit (GRU) algorithm to increase the capability of multiplexing and the ability to detect Bragg wavelengths with greater accuracy. Several Fiber Bragg grating (FBG) sensors are coupled with power ratios of 90:10 and 80:10, respectively in the suggested experimental setup. We used the latest IWDM multiplexing technique for the proposed scheme, as the IWDM system increases the number of sensors and allows us to alleviate the limited operational region drawback of conventional wavelength division multiplexing (WDM). However, IWDM has a crosstalk problem that causes high-sensor signal measurement errors. Thus, we proposed the GRU model to overcome this crosstalk or overlapping problem by converting the spectral detection problem into a regression problem and considered the sequence of spectral features as input. By feeding this sequential spectrum dataset into the GRU model, we trained the GRU system until we achieved optimal efficiency. Consequently, the well-trained GRU model quickly and accurately identifies the Bragg wavelength of each FBG from the overlapping spectra. The Bragg wavelength detection performance of our proposed GRU model is tested or validated using different numbers of FBG sensors, such as 3-FBG, 5-FBG, 7-FBG, and 10-FBG, separately. As a result, the experiment result proves that the well-trained GRU model accurately identifies each FBG Bragg wavelength, and even the number of FBG sensors increase, as well as the spectra of FBGs, which are partially or fully overlapped. Therefore, to boost the detection efficiency, reliability, and to increase the multiplexing capabilities of FBG sensor networks, the proposed sensor system is better than the other previously proposed methods. MDPI 2020-12-21 /pmc/articles/PMC7767492/ /pubmed/33371509 http://dx.doi.org/10.3390/s20247355 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dehnaw, Amare Mulatie
Manie, Yibeltal Chanie
Chen, Ya Yu
Chiu, Po Han
Huang, Hung Wei
Chen, Guan Wei
Peng, Peng Chun
Design Reliable Bus Structure Distributed Fiber Bragg Grating Sensor Network Using Gated Recurrent Unit Network
title Design Reliable Bus Structure Distributed Fiber Bragg Grating Sensor Network Using Gated Recurrent Unit Network
title_full Design Reliable Bus Structure Distributed Fiber Bragg Grating Sensor Network Using Gated Recurrent Unit Network
title_fullStr Design Reliable Bus Structure Distributed Fiber Bragg Grating Sensor Network Using Gated Recurrent Unit Network
title_full_unstemmed Design Reliable Bus Structure Distributed Fiber Bragg Grating Sensor Network Using Gated Recurrent Unit Network
title_short Design Reliable Bus Structure Distributed Fiber Bragg Grating Sensor Network Using Gated Recurrent Unit Network
title_sort design reliable bus structure distributed fiber bragg grating sensor network using gated recurrent unit network
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7767492/
https://www.ncbi.nlm.nih.gov/pubmed/33371509
http://dx.doi.org/10.3390/s20247355
work_keys_str_mv AT dehnawamaremulatie designreliablebusstructuredistributedfiberbragggratingsensornetworkusinggatedrecurrentunitnetwork
AT manieyibeltalchanie designreliablebusstructuredistributedfiberbragggratingsensornetworkusinggatedrecurrentunitnetwork
AT chenyayu designreliablebusstructuredistributedfiberbragggratingsensornetworkusinggatedrecurrentunitnetwork
AT chiupohan designreliablebusstructuredistributedfiberbragggratingsensornetworkusinggatedrecurrentunitnetwork
AT huanghungwei designreliablebusstructuredistributedfiberbragggratingsensornetworkusinggatedrecurrentunitnetwork
AT chenguanwei designreliablebusstructuredistributedfiberbragggratingsensornetworkusinggatedrecurrentunitnetwork
AT pengpengchun designreliablebusstructuredistributedfiberbragggratingsensornetworkusinggatedrecurrentunitnetwork