Cargando…

Control of Methicillin-Resistant Staphylococcus aureus Strains Associated With a Hospital Outbreak Involving Contamination From Anesthesia Equipment Using UV-C

Methicillin-resistant Staphylococcus aureus (MRSA) is considered an opportunistic pathogen in humans and is mainly associated with healthcare-associated infections (HCAIs). This bacterium colonizes the skin and mucous membranes of healthy people and causes frequent hospital outbreaks. The aim of thi...

Descripción completa

Detalles Bibliográficos
Autores principales: Ochoa, Sara A., Cruz-Córdova, Ariadnna, Mancilla-Rojano, Jetsi, Escalona-Venegas, Gerardo, Esteban-Kenel, Veronica, Franco-Hernández, Isabel, Parra-Ortega, Israel, Arellano-Galindo, José, Hernández-Castro, Rigoberto, Perez-López, Citlalli F., De la Rosa-Zamboni, Daniela, Xicohtencatl-Cortes, Juan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7767929/
https://www.ncbi.nlm.nih.gov/pubmed/33381094
http://dx.doi.org/10.3389/fmicb.2020.600093
_version_ 1783629070711390208
author Ochoa, Sara A.
Cruz-Córdova, Ariadnna
Mancilla-Rojano, Jetsi
Escalona-Venegas, Gerardo
Esteban-Kenel, Veronica
Franco-Hernández, Isabel
Parra-Ortega, Israel
Arellano-Galindo, José
Hernández-Castro, Rigoberto
Perez-López, Citlalli F.
De la Rosa-Zamboni, Daniela
Xicohtencatl-Cortes, Juan
author_facet Ochoa, Sara A.
Cruz-Córdova, Ariadnna
Mancilla-Rojano, Jetsi
Escalona-Venegas, Gerardo
Esteban-Kenel, Veronica
Franco-Hernández, Isabel
Parra-Ortega, Israel
Arellano-Galindo, José
Hernández-Castro, Rigoberto
Perez-López, Citlalli F.
De la Rosa-Zamboni, Daniela
Xicohtencatl-Cortes, Juan
author_sort Ochoa, Sara A.
collection PubMed
description Methicillin-resistant Staphylococcus aureus (MRSA) is considered an opportunistic pathogen in humans and is mainly associated with healthcare-associated infections (HCAIs). This bacterium colonizes the skin and mucous membranes of healthy people and causes frequent hospital outbreaks. The aim of this study was to perform molecular typing of the staphylococcal cassette chromosome mec (SCCmec) and agr loci as wells as to establish the pulsotypes and clonal complexes (CCs) for MRSA and methicillin-sensitive S. aureus (MSSA) outbreaks associated with the operating room (OR) at a pediatric hospital. Twenty-five clinical strains of S. aureus (19 MRSA and 6 MSSA strains) were recovered from the outbreak (patients, anesthesia equipment, and nasopharyngeal exudates from external service anesthesia technicians). These clinical S. aureus strains were mainly resistant to benzylpenicillin (100%) and erythromycin (84%) and were susceptible to vancomycin and nitrofurantoin. The SCCmec type II was amplified in 84% of the S. aureus strains, and the most frequent type of the agr locus was agrII, which was amplified in 72% of the strains; however, the agrI and agrIII genes were mainly detected in MSSA strains. A pulsed-field gel electrophoresis (PFGE) analysis grouped the 25 strains into 16 pulsotypes (P), the most frequent of which was P1, including 10 MRSA strains related to the anesthesia equipment, external service anesthesia technicians, and hospitalized patients. Multilocus sequence typing (MLST) identified 15 sequence types (STs) distributed in nine CCs. The most prevalent ST was ST1011, belonging to CC5, which was associated with the SCCmec type II and agrII type. We postulate that the external service anesthesia technicians were MRSA carriers and that these strains were indirectly transmitted from the contaminated anesthesia equipment that was inappropriately disinfected. Finally, the MRSA outbreak was controlled when the anesthesia equipment disinfection was improved and hand hygiene was reinforced.
format Online
Article
Text
id pubmed-7767929
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-77679292020-12-29 Control of Methicillin-Resistant Staphylococcus aureus Strains Associated With a Hospital Outbreak Involving Contamination From Anesthesia Equipment Using UV-C Ochoa, Sara A. Cruz-Córdova, Ariadnna Mancilla-Rojano, Jetsi Escalona-Venegas, Gerardo Esteban-Kenel, Veronica Franco-Hernández, Isabel Parra-Ortega, Israel Arellano-Galindo, José Hernández-Castro, Rigoberto Perez-López, Citlalli F. De la Rosa-Zamboni, Daniela Xicohtencatl-Cortes, Juan Front Microbiol Microbiology Methicillin-resistant Staphylococcus aureus (MRSA) is considered an opportunistic pathogen in humans and is mainly associated with healthcare-associated infections (HCAIs). This bacterium colonizes the skin and mucous membranes of healthy people and causes frequent hospital outbreaks. The aim of this study was to perform molecular typing of the staphylococcal cassette chromosome mec (SCCmec) and agr loci as wells as to establish the pulsotypes and clonal complexes (CCs) for MRSA and methicillin-sensitive S. aureus (MSSA) outbreaks associated with the operating room (OR) at a pediatric hospital. Twenty-five clinical strains of S. aureus (19 MRSA and 6 MSSA strains) were recovered from the outbreak (patients, anesthesia equipment, and nasopharyngeal exudates from external service anesthesia technicians). These clinical S. aureus strains were mainly resistant to benzylpenicillin (100%) and erythromycin (84%) and were susceptible to vancomycin and nitrofurantoin. The SCCmec type II was amplified in 84% of the S. aureus strains, and the most frequent type of the agr locus was agrII, which was amplified in 72% of the strains; however, the agrI and agrIII genes were mainly detected in MSSA strains. A pulsed-field gel electrophoresis (PFGE) analysis grouped the 25 strains into 16 pulsotypes (P), the most frequent of which was P1, including 10 MRSA strains related to the anesthesia equipment, external service anesthesia technicians, and hospitalized patients. Multilocus sequence typing (MLST) identified 15 sequence types (STs) distributed in nine CCs. The most prevalent ST was ST1011, belonging to CC5, which was associated with the SCCmec type II and agrII type. We postulate that the external service anesthesia technicians were MRSA carriers and that these strains were indirectly transmitted from the contaminated anesthesia equipment that was inappropriately disinfected. Finally, the MRSA outbreak was controlled when the anesthesia equipment disinfection was improved and hand hygiene was reinforced. Frontiers Media S.A. 2020-12-14 /pmc/articles/PMC7767929/ /pubmed/33381094 http://dx.doi.org/10.3389/fmicb.2020.600093 Text en Copyright © 2020 Ochoa, Cruz-Córdova, Mancilla-Rojano, Escalona-Venegas, Esteban-Kenel, Franco-Hernández, Parra-Ortega, Arellano-Galindo, Hernández-Castro, Perez-López, De la Rosa-Zamboni and Xicohtencatl-Cortes. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Microbiology
Ochoa, Sara A.
Cruz-Córdova, Ariadnna
Mancilla-Rojano, Jetsi
Escalona-Venegas, Gerardo
Esteban-Kenel, Veronica
Franco-Hernández, Isabel
Parra-Ortega, Israel
Arellano-Galindo, José
Hernández-Castro, Rigoberto
Perez-López, Citlalli F.
De la Rosa-Zamboni, Daniela
Xicohtencatl-Cortes, Juan
Control of Methicillin-Resistant Staphylococcus aureus Strains Associated With a Hospital Outbreak Involving Contamination From Anesthesia Equipment Using UV-C
title Control of Methicillin-Resistant Staphylococcus aureus Strains Associated With a Hospital Outbreak Involving Contamination From Anesthesia Equipment Using UV-C
title_full Control of Methicillin-Resistant Staphylococcus aureus Strains Associated With a Hospital Outbreak Involving Contamination From Anesthesia Equipment Using UV-C
title_fullStr Control of Methicillin-Resistant Staphylococcus aureus Strains Associated With a Hospital Outbreak Involving Contamination From Anesthesia Equipment Using UV-C
title_full_unstemmed Control of Methicillin-Resistant Staphylococcus aureus Strains Associated With a Hospital Outbreak Involving Contamination From Anesthesia Equipment Using UV-C
title_short Control of Methicillin-Resistant Staphylococcus aureus Strains Associated With a Hospital Outbreak Involving Contamination From Anesthesia Equipment Using UV-C
title_sort control of methicillin-resistant staphylococcus aureus strains associated with a hospital outbreak involving contamination from anesthesia equipment using uv-c
topic Microbiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7767929/
https://www.ncbi.nlm.nih.gov/pubmed/33381094
http://dx.doi.org/10.3389/fmicb.2020.600093
work_keys_str_mv AT ochoasaraa controlofmethicillinresistantstaphylococcusaureusstrainsassociatedwithahospitaloutbreakinvolvingcontaminationfromanesthesiaequipmentusinguvc
AT cruzcordovaariadnna controlofmethicillinresistantstaphylococcusaureusstrainsassociatedwithahospitaloutbreakinvolvingcontaminationfromanesthesiaequipmentusinguvc
AT mancillarojanojetsi controlofmethicillinresistantstaphylococcusaureusstrainsassociatedwithahospitaloutbreakinvolvingcontaminationfromanesthesiaequipmentusinguvc
AT escalonavenegasgerardo controlofmethicillinresistantstaphylococcusaureusstrainsassociatedwithahospitaloutbreakinvolvingcontaminationfromanesthesiaequipmentusinguvc
AT estebankenelveronica controlofmethicillinresistantstaphylococcusaureusstrainsassociatedwithahospitaloutbreakinvolvingcontaminationfromanesthesiaequipmentusinguvc
AT francohernandezisabel controlofmethicillinresistantstaphylococcusaureusstrainsassociatedwithahospitaloutbreakinvolvingcontaminationfromanesthesiaequipmentusinguvc
AT parraortegaisrael controlofmethicillinresistantstaphylococcusaureusstrainsassociatedwithahospitaloutbreakinvolvingcontaminationfromanesthesiaequipmentusinguvc
AT arellanogalindojose controlofmethicillinresistantstaphylococcusaureusstrainsassociatedwithahospitaloutbreakinvolvingcontaminationfromanesthesiaequipmentusinguvc
AT hernandezcastrorigoberto controlofmethicillinresistantstaphylococcusaureusstrainsassociatedwithahospitaloutbreakinvolvingcontaminationfromanesthesiaequipmentusinguvc
AT perezlopezcitlallif controlofmethicillinresistantstaphylococcusaureusstrainsassociatedwithahospitaloutbreakinvolvingcontaminationfromanesthesiaequipmentusinguvc
AT delarosazambonidaniela controlofmethicillinresistantstaphylococcusaureusstrainsassociatedwithahospitaloutbreakinvolvingcontaminationfromanesthesiaequipmentusinguvc
AT xicohtencatlcortesjuan controlofmethicillinresistantstaphylococcusaureusstrainsassociatedwithahospitaloutbreakinvolvingcontaminationfromanesthesiaequipmentusinguvc