Cargando…

Accuracy of root-end resection using a digital guide in endodontic surgery: An in vitro study

BACKGROUND/PURPOSE: It is difficult to achieve accurate root-end resection clinically. This in vitro study was conducted to evaluate the operation accuracy of a digital endodontic surgical guide. MATERIALS AND METHODS: 56 extracted maxillary anterior teeth were prepared for endodontic surgical model...

Descripción completa

Detalles Bibliográficos
Autores principales: Peng, Li, Zhao, Jing, Wang, Zu-Hua, Sun, Yu-Chun, Liang, Yu-Hong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Association for Dental Sciences of the Republic of China 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7770308/
https://www.ncbi.nlm.nih.gov/pubmed/33384777
http://dx.doi.org/10.1016/j.jds.2020.06.024
_version_ 1783629481169125376
author Peng, Li
Zhao, Jing
Wang, Zu-Hua
Sun, Yu-Chun
Liang, Yu-Hong
author_facet Peng, Li
Zhao, Jing
Wang, Zu-Hua
Sun, Yu-Chun
Liang, Yu-Hong
author_sort Peng, Li
collection PubMed
description BACKGROUND/PURPOSE: It is difficult to achieve accurate root-end resection clinically. This in vitro study was conducted to evaluate the operation accuracy of a digital endodontic surgical guide. MATERIALS AND METHODS: 56 extracted maxillary anterior teeth were prepared for endodontic surgical models. The models were randomly divided into 4 groups equally according to the guide (with guide/no guide) and the operator (experienced/inexperienced). Endodontic microsurgeries were performed on models in each group. The deviations in length and angle of the root-end resection were measured based on the optical scanning data of the pre- and postoperative teeth. The general linear model was performed to analyze the effect of a guide on root-end resection deviation. RESULTS: Using a guide, the mean length deviation for experienced/inexperienced operators reduced from 0.99 mm (95% CI [confidence interval, CI], 0.66–1.33 mm)/1.18 mm (95% CI, 0.50–1.86 mm) to 0.31 mm (95% CI, 0.20–0.42 mm)/0.31 mm (95% CI, 0.24–0.37 mm). The mean angle deviation for experienced/inexperienced operators reduced from 16.74° (95% CI, 10.61–22.86°)/15.06° (95% CI, 9.19–20.94°) to 5.04° (95% CI, 3.31–6.77°)/6.79° (95% CI, 4.91–8.67°). The difference was significant between procedures performed with and without a guide (P < 0.01). CONCLUSION: Application of the digital guide in vitro endodontic surgery could improve the accuracy of root-end resection.
format Online
Article
Text
id pubmed-7770308
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Association for Dental Sciences of the Republic of China
record_format MEDLINE/PubMed
spelling pubmed-77703082020-12-30 Accuracy of root-end resection using a digital guide in endodontic surgery: An in vitro study Peng, Li Zhao, Jing Wang, Zu-Hua Sun, Yu-Chun Liang, Yu-Hong J Dent Sci Original Article BACKGROUND/PURPOSE: It is difficult to achieve accurate root-end resection clinically. This in vitro study was conducted to evaluate the operation accuracy of a digital endodontic surgical guide. MATERIALS AND METHODS: 56 extracted maxillary anterior teeth were prepared for endodontic surgical models. The models were randomly divided into 4 groups equally according to the guide (with guide/no guide) and the operator (experienced/inexperienced). Endodontic microsurgeries were performed on models in each group. The deviations in length and angle of the root-end resection were measured based on the optical scanning data of the pre- and postoperative teeth. The general linear model was performed to analyze the effect of a guide on root-end resection deviation. RESULTS: Using a guide, the mean length deviation for experienced/inexperienced operators reduced from 0.99 mm (95% CI [confidence interval, CI], 0.66–1.33 mm)/1.18 mm (95% CI, 0.50–1.86 mm) to 0.31 mm (95% CI, 0.20–0.42 mm)/0.31 mm (95% CI, 0.24–0.37 mm). The mean angle deviation for experienced/inexperienced operators reduced from 16.74° (95% CI, 10.61–22.86°)/15.06° (95% CI, 9.19–20.94°) to 5.04° (95% CI, 3.31–6.77°)/6.79° (95% CI, 4.91–8.67°). The difference was significant between procedures performed with and without a guide (P < 0.01). CONCLUSION: Application of the digital guide in vitro endodontic surgery could improve the accuracy of root-end resection. Association for Dental Sciences of the Republic of China 2021-01 2020-08-16 /pmc/articles/PMC7770308/ /pubmed/33384777 http://dx.doi.org/10.1016/j.jds.2020.06.024 Text en © 2020 Association for Dental Sciences of the Republic of China. Publishing services by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Peng, Li
Zhao, Jing
Wang, Zu-Hua
Sun, Yu-Chun
Liang, Yu-Hong
Accuracy of root-end resection using a digital guide in endodontic surgery: An in vitro study
title Accuracy of root-end resection using a digital guide in endodontic surgery: An in vitro study
title_full Accuracy of root-end resection using a digital guide in endodontic surgery: An in vitro study
title_fullStr Accuracy of root-end resection using a digital guide in endodontic surgery: An in vitro study
title_full_unstemmed Accuracy of root-end resection using a digital guide in endodontic surgery: An in vitro study
title_short Accuracy of root-end resection using a digital guide in endodontic surgery: An in vitro study
title_sort accuracy of root-end resection using a digital guide in endodontic surgery: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7770308/
https://www.ncbi.nlm.nih.gov/pubmed/33384777
http://dx.doi.org/10.1016/j.jds.2020.06.024
work_keys_str_mv AT pengli accuracyofrootendresectionusingadigitalguideinendodonticsurgeryaninvitrostudy
AT zhaojing accuracyofrootendresectionusingadigitalguideinendodonticsurgeryaninvitrostudy
AT wangzuhua accuracyofrootendresectionusingadigitalguideinendodonticsurgeryaninvitrostudy
AT sunyuchun accuracyofrootendresectionusingadigitalguideinendodonticsurgeryaninvitrostudy
AT liangyuhong accuracyofrootendresectionusingadigitalguideinendodonticsurgeryaninvitrostudy