Cargando…

Fully automatic peak frequency estimation of the posterior dominant rhythm in a large retrospective hospital EEG cohort

OBJECTIVE: To develop and test a fully automated method for estimation of the peak frequency of the posterior dominant rhythm (PDR) in a large retrospective EEG cohort. METHODS: Thresholding was used to select suitable EEG data segments for spectral estimation for electrode O1 and O2. A random sampl...

Descripción completa

Detalles Bibliográficos
Autores principales: Zibrandtsen, Ivan C., Kjaer, Troels W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7771042/
https://www.ncbi.nlm.nih.gov/pubmed/33385100
http://dx.doi.org/10.1016/j.cnp.2020.11.001
_version_ 1783629636456939520
author Zibrandtsen, Ivan C.
Kjaer, Troels W.
author_facet Zibrandtsen, Ivan C.
Kjaer, Troels W.
author_sort Zibrandtsen, Ivan C.
collection PubMed
description OBJECTIVE: To develop and test a fully automated method for estimation of the peak frequency of the posterior dominant rhythm (PDR) in a large retrospective EEG cohort. METHODS: Thresholding was used to select suitable EEG data segments for spectral estimation for electrode O1 and O2. A random sample of 100 peak frequency estimates were blindly rated by two independent raters to validate the results of the automatic PDR peak frequency estimates. We investigated the relationship with age, sex and binary EEG classification. RESULTS: There were 9197 eligible EEGs which resulted in a total of 6104 PDR peak frequency estimates. The relationship between automatic estimates and age was found to be consistent with the literature. The correlation between human ratings and automatic scoring was very high, rho = 0.94–0.95. There was a sex difference of d = 0.33 emerging at puberty with females having a faster PDR peak frequency than males. CONCLUSIONS: Fully automatic PDR peak frequency estimation not dependent on annotated EEG produced results that are very close to human ratings. SIGNIFICANCE: PDR peak frequency can be automatically estimated. A compiled version of the algorithm is included as an app for independent use.
format Online
Article
Text
id pubmed-7771042
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-77710422020-12-30 Fully automatic peak frequency estimation of the posterior dominant rhythm in a large retrospective hospital EEG cohort Zibrandtsen, Ivan C. Kjaer, Troels W. Clin Neurophysiol Pract Research Paper OBJECTIVE: To develop and test a fully automated method for estimation of the peak frequency of the posterior dominant rhythm (PDR) in a large retrospective EEG cohort. METHODS: Thresholding was used to select suitable EEG data segments for spectral estimation for electrode O1 and O2. A random sample of 100 peak frequency estimates were blindly rated by two independent raters to validate the results of the automatic PDR peak frequency estimates. We investigated the relationship with age, sex and binary EEG classification. RESULTS: There were 9197 eligible EEGs which resulted in a total of 6104 PDR peak frequency estimates. The relationship between automatic estimates and age was found to be consistent with the literature. The correlation between human ratings and automatic scoring was very high, rho = 0.94–0.95. There was a sex difference of d = 0.33 emerging at puberty with females having a faster PDR peak frequency than males. CONCLUSIONS: Fully automatic PDR peak frequency estimation not dependent on annotated EEG produced results that are very close to human ratings. SIGNIFICANCE: PDR peak frequency can be automatically estimated. A compiled version of the algorithm is included as an app for independent use. Elsevier 2020-12-03 /pmc/articles/PMC7771042/ /pubmed/33385100 http://dx.doi.org/10.1016/j.cnp.2020.11.001 Text en © 2020 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Paper
Zibrandtsen, Ivan C.
Kjaer, Troels W.
Fully automatic peak frequency estimation of the posterior dominant rhythm in a large retrospective hospital EEG cohort
title Fully automatic peak frequency estimation of the posterior dominant rhythm in a large retrospective hospital EEG cohort
title_full Fully automatic peak frequency estimation of the posterior dominant rhythm in a large retrospective hospital EEG cohort
title_fullStr Fully automatic peak frequency estimation of the posterior dominant rhythm in a large retrospective hospital EEG cohort
title_full_unstemmed Fully automatic peak frequency estimation of the posterior dominant rhythm in a large retrospective hospital EEG cohort
title_short Fully automatic peak frequency estimation of the posterior dominant rhythm in a large retrospective hospital EEG cohort
title_sort fully automatic peak frequency estimation of the posterior dominant rhythm in a large retrospective hospital eeg cohort
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7771042/
https://www.ncbi.nlm.nih.gov/pubmed/33385100
http://dx.doi.org/10.1016/j.cnp.2020.11.001
work_keys_str_mv AT zibrandtsenivanc fullyautomaticpeakfrequencyestimationoftheposteriordominantrhythminalargeretrospectivehospitaleegcohort
AT kjaertroelsw fullyautomaticpeakfrequencyestimationoftheposteriordominantrhythminalargeretrospectivehospitaleegcohort