Cargando…
Stability of SARS-CoV-2 RNA in Viral Lysis Buffer Stored at Different Temperatures
Objectives The present COVID-19 pandemic resulted in an increased need for molecular diagnostic testing. Delay in the specimen processing and suboptimal storage of suspected samples in laboratories leads to degradation of SARS-CoV-2 viral RNA. Viral lysis buffers from RNA extraction kits have the po...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Thieme Medical and Scientific Publishers Pvt. Ltd.
2020
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7773443/ https://www.ncbi.nlm.nih.gov/pubmed/33390676 http://dx.doi.org/10.1055/s-0040-1722551 |
_version_ | 1783630045921673216 |
---|---|
author | Perumal, Nagaraj Jain, Rajeev Kumar Shrivastava, Rakesh Lalwani, Jaya Chaurasia, Deepti |
author_facet | Perumal, Nagaraj Jain, Rajeev Kumar Shrivastava, Rakesh Lalwani, Jaya Chaurasia, Deepti |
author_sort | Perumal, Nagaraj |
collection | PubMed |
description | Objectives The present COVID-19 pandemic resulted in an increased need for molecular diagnostic testing. Delay in the specimen processing and suboptimal storage of suspected samples in laboratories leads to degradation of SARS-CoV-2 viral RNA. Viral lysis buffers from RNA extraction kits have the potential to stabilize RNA. Hence, this study aimed to investigate the stability of SARS-CoV-2 RNA in viral lysis buffer at different temperatures and time periods. Materials and Methods Aliquots of samples with known SARS-CoV-2 RNA were processed in viral lysis buffers simultaneously, stored separately at 2 to 8°C and 22 to 28°C for 24 hours, 48 hours and 72 hours. SARS-CoV-2 viral RNA was extracted from each aliquot and analyzed using multiplex real-time PCR. Results SARS-CoV-2 RNA in samples placed in viral lysis buffer was stable for 48 hours at both 2 to 8°C and 22 to 28°C temperatures. Slight decline in the viral RNA quantity was found on aliquots tested after 48 hours of both the temperatures. Conclusions Viral lysis buffer maintains the integrity of SARS-CoV-2 RNA for up to 48 hours even at room temperature and supports delayed diagnosis with an overwhelming sample load in testing laboratories. |
format | Online Article Text |
id | pubmed-7773443 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Thieme Medical and Scientific Publishers Pvt. Ltd. |
record_format | MEDLINE/PubMed |
spelling | pubmed-77734432020-12-31 Stability of SARS-CoV-2 RNA in Viral Lysis Buffer Stored at Different Temperatures Perumal, Nagaraj Jain, Rajeev Kumar Shrivastava, Rakesh Lalwani, Jaya Chaurasia, Deepti J Lab Physicians Objectives The present COVID-19 pandemic resulted in an increased need for molecular diagnostic testing. Delay in the specimen processing and suboptimal storage of suspected samples in laboratories leads to degradation of SARS-CoV-2 viral RNA. Viral lysis buffers from RNA extraction kits have the potential to stabilize RNA. Hence, this study aimed to investigate the stability of SARS-CoV-2 RNA in viral lysis buffer at different temperatures and time periods. Materials and Methods Aliquots of samples with known SARS-CoV-2 RNA were processed in viral lysis buffers simultaneously, stored separately at 2 to 8°C and 22 to 28°C for 24 hours, 48 hours and 72 hours. SARS-CoV-2 viral RNA was extracted from each aliquot and analyzed using multiplex real-time PCR. Results SARS-CoV-2 RNA in samples placed in viral lysis buffer was stable for 48 hours at both 2 to 8°C and 22 to 28°C temperatures. Slight decline in the viral RNA quantity was found on aliquots tested after 48 hours of both the temperatures. Conclusions Viral lysis buffer maintains the integrity of SARS-CoV-2 RNA for up to 48 hours even at room temperature and supports delayed diagnosis with an overwhelming sample load in testing laboratories. Thieme Medical and Scientific Publishers Pvt. Ltd. 2020-12 2020-12-30 /pmc/articles/PMC7773443/ /pubmed/33390676 http://dx.doi.org/10.1055/s-0040-1722551 Text en The Indian Association of Laboratory Physicians. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited. |
spellingShingle | Perumal, Nagaraj Jain, Rajeev Kumar Shrivastava, Rakesh Lalwani, Jaya Chaurasia, Deepti Stability of SARS-CoV-2 RNA in Viral Lysis Buffer Stored at Different Temperatures |
title | Stability of SARS-CoV-2 RNA in Viral Lysis Buffer Stored at Different Temperatures |
title_full | Stability of SARS-CoV-2 RNA in Viral Lysis Buffer Stored at Different Temperatures |
title_fullStr | Stability of SARS-CoV-2 RNA in Viral Lysis Buffer Stored at Different Temperatures |
title_full_unstemmed | Stability of SARS-CoV-2 RNA in Viral Lysis Buffer Stored at Different Temperatures |
title_short | Stability of SARS-CoV-2 RNA in Viral Lysis Buffer Stored at Different Temperatures |
title_sort | stability of sars-cov-2 rna in viral lysis buffer stored at different temperatures |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7773443/ https://www.ncbi.nlm.nih.gov/pubmed/33390676 http://dx.doi.org/10.1055/s-0040-1722551 |
work_keys_str_mv | AT perumalnagaraj stabilityofsarscov2rnainvirallysisbufferstoredatdifferenttemperatures AT jainrajeevkumar stabilityofsarscov2rnainvirallysisbufferstoredatdifferenttemperatures AT shrivastavarakesh stabilityofsarscov2rnainvirallysisbufferstoredatdifferenttemperatures AT lalwanijaya stabilityofsarscov2rnainvirallysisbufferstoredatdifferenttemperatures AT chaurasiadeepti stabilityofsarscov2rnainvirallysisbufferstoredatdifferenttemperatures |