Cargando…

Stability of SARS-CoV-2 RNA in Viral Lysis Buffer Stored at Different Temperatures

Objectives  The present COVID-19 pandemic resulted in an increased need for molecular diagnostic testing. Delay in the specimen processing and suboptimal storage of suspected samples in laboratories leads to degradation of SARS-CoV-2 viral RNA. Viral lysis buffers from RNA extraction kits have the po...

Descripción completa

Detalles Bibliográficos
Autores principales: Perumal, Nagaraj, Jain, Rajeev Kumar, Shrivastava, Rakesh, Lalwani, Jaya, Chaurasia, Deepti
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical and Scientific Publishers Pvt. Ltd. 2020
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7773443/
https://www.ncbi.nlm.nih.gov/pubmed/33390676
http://dx.doi.org/10.1055/s-0040-1722551
_version_ 1783630045921673216
author Perumal, Nagaraj
Jain, Rajeev Kumar
Shrivastava, Rakesh
Lalwani, Jaya
Chaurasia, Deepti
author_facet Perumal, Nagaraj
Jain, Rajeev Kumar
Shrivastava, Rakesh
Lalwani, Jaya
Chaurasia, Deepti
author_sort Perumal, Nagaraj
collection PubMed
description Objectives  The present COVID-19 pandemic resulted in an increased need for molecular diagnostic testing. Delay in the specimen processing and suboptimal storage of suspected samples in laboratories leads to degradation of SARS-CoV-2 viral RNA. Viral lysis buffers from RNA extraction kits have the potential to stabilize RNA. Hence, this study aimed to investigate the stability of SARS-CoV-2 RNA in viral lysis buffer at different temperatures and time periods. Materials and Methods  Aliquots of samples with known SARS-CoV-2 RNA were processed in viral lysis buffers simultaneously, stored separately at 2 to 8°C and 22 to 28°C for 24 hours, 48 hours and 72 hours. SARS-CoV-2 viral RNA was extracted from each aliquot and analyzed using multiplex real-time PCR. Results  SARS-CoV-2 RNA in samples placed in viral lysis buffer was stable for 48 hours at both 2 to 8°C and 22 to 28°C temperatures. Slight decline in the viral RNA quantity was found on aliquots tested after 48 hours of both the temperatures. Conclusions  Viral lysis buffer maintains the integrity of SARS-CoV-2 RNA for up to 48 hours even at room temperature and supports delayed diagnosis with an overwhelming sample load in testing laboratories.
format Online
Article
Text
id pubmed-7773443
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Thieme Medical and Scientific Publishers Pvt. Ltd.
record_format MEDLINE/PubMed
spelling pubmed-77734432020-12-31 Stability of SARS-CoV-2 RNA in Viral Lysis Buffer Stored at Different Temperatures Perumal, Nagaraj Jain, Rajeev Kumar Shrivastava, Rakesh Lalwani, Jaya Chaurasia, Deepti J Lab Physicians Objectives  The present COVID-19 pandemic resulted in an increased need for molecular diagnostic testing. Delay in the specimen processing and suboptimal storage of suspected samples in laboratories leads to degradation of SARS-CoV-2 viral RNA. Viral lysis buffers from RNA extraction kits have the potential to stabilize RNA. Hence, this study aimed to investigate the stability of SARS-CoV-2 RNA in viral lysis buffer at different temperatures and time periods. Materials and Methods  Aliquots of samples with known SARS-CoV-2 RNA were processed in viral lysis buffers simultaneously, stored separately at 2 to 8°C and 22 to 28°C for 24 hours, 48 hours and 72 hours. SARS-CoV-2 viral RNA was extracted from each aliquot and analyzed using multiplex real-time PCR. Results  SARS-CoV-2 RNA in samples placed in viral lysis buffer was stable for 48 hours at both 2 to 8°C and 22 to 28°C temperatures. Slight decline in the viral RNA quantity was found on aliquots tested after 48 hours of both the temperatures. Conclusions  Viral lysis buffer maintains the integrity of SARS-CoV-2 RNA for up to 48 hours even at room temperature and supports delayed diagnosis with an overwhelming sample load in testing laboratories. Thieme Medical and Scientific Publishers Pvt. Ltd. 2020-12 2020-12-30 /pmc/articles/PMC7773443/ /pubmed/33390676 http://dx.doi.org/10.1055/s-0040-1722551 Text en The Indian Association of Laboratory Physicians. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Perumal, Nagaraj
Jain, Rajeev Kumar
Shrivastava, Rakesh
Lalwani, Jaya
Chaurasia, Deepti
Stability of SARS-CoV-2 RNA in Viral Lysis Buffer Stored at Different Temperatures
title Stability of SARS-CoV-2 RNA in Viral Lysis Buffer Stored at Different Temperatures
title_full Stability of SARS-CoV-2 RNA in Viral Lysis Buffer Stored at Different Temperatures
title_fullStr Stability of SARS-CoV-2 RNA in Viral Lysis Buffer Stored at Different Temperatures
title_full_unstemmed Stability of SARS-CoV-2 RNA in Viral Lysis Buffer Stored at Different Temperatures
title_short Stability of SARS-CoV-2 RNA in Viral Lysis Buffer Stored at Different Temperatures
title_sort stability of sars-cov-2 rna in viral lysis buffer stored at different temperatures
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7773443/
https://www.ncbi.nlm.nih.gov/pubmed/33390676
http://dx.doi.org/10.1055/s-0040-1722551
work_keys_str_mv AT perumalnagaraj stabilityofsarscov2rnainvirallysisbufferstoredatdifferenttemperatures
AT jainrajeevkumar stabilityofsarscov2rnainvirallysisbufferstoredatdifferenttemperatures
AT shrivastavarakesh stabilityofsarscov2rnainvirallysisbufferstoredatdifferenttemperatures
AT lalwanijaya stabilityofsarscov2rnainvirallysisbufferstoredatdifferenttemperatures
AT chaurasiadeepti stabilityofsarscov2rnainvirallysisbufferstoredatdifferenttemperatures