Cargando…

Improved digital chest tomosynthesis image quality by use of a projection-based dual-energy virtual monochromatic convolutional neural network with super resolution

We developed a novel dual-energy (DE) virtual monochromatic (VM) very-deep super-resolution (VDSR) method with an unsharp masking reconstruction algorithm (DE–VM–VDSR) that uses projection data to improve the nodule contrast and reduce ripple artifacts during chest digital tomosynthesis (DT). For es...

Descripción completa

Detalles Bibliográficos
Autores principales: Gomi, Tsutomu, Hara, Hidetake, Watanabe, Yusuke, Mizukami, Shinya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7774945/
https://www.ncbi.nlm.nih.gov/pubmed/33382766
http://dx.doi.org/10.1371/journal.pone.0244745
_version_ 1783630367907905536
author Gomi, Tsutomu
Hara, Hidetake
Watanabe, Yusuke
Mizukami, Shinya
author_facet Gomi, Tsutomu
Hara, Hidetake
Watanabe, Yusuke
Mizukami, Shinya
author_sort Gomi, Tsutomu
collection PubMed
description We developed a novel dual-energy (DE) virtual monochromatic (VM) very-deep super-resolution (VDSR) method with an unsharp masking reconstruction algorithm (DE–VM–VDSR) that uses projection data to improve the nodule contrast and reduce ripple artifacts during chest digital tomosynthesis (DT). For estimating the residual errors from high-resolution and multiscale VM images from the projection space, the DE–VM–VDSR algorithm employs a training network (mini-batch stochastic gradient-descent algorithm with momentum) and a hybrid super-resolution (SR) image [simultaneous algebraic reconstruction technique (SART) total-variation (TV) first-iterative shrinkage–thresholding algorithm (FISTA); SART–TV–FISTA] that involves subjective reconstruction with bilateral filtering (BF) [DE–VM–VDSR with BF]. DE-DT imaging was accomplished by pulsed X-ray exposures rapidly switched between low (60 kV, 37 projection) and high (120 kV, 37 projection) tube-potential kVp by employing a 40° swing angle. This was followed by comparison of images obtained employing the conventional polychromatic filtered backprojection (FBP), SART, SART–TV–FISTA, and DE–VM–SART–TV–FISTA algorithms. The improvements in contrast, ripple artifacts, and resolution were compared using the signal-difference-to-noise ratio (SDNR), Gumbel distribution of the largest variations, radial modulation transfer function (radial MTF) for a chest phantom with simulated ground-glass opacity (GGO) nodules, and noise power spectrum (NPS) for uniform water phantom. The novel DE–VM–VDSR with BF improved the overall performance in terms of SDNR (DE–VM–VDSR with BF: 0.1603, without BF: 0.1517; FBP: 0.0521; SART: 0.0645; SART–TV–FISTA: 0.0984; and DE–VM–SART–TV–FISTA: 0.1004), obtained a Gumbel distribution that yielded good images showing the type of simulated GGO nodules used in the chest phantom, and reduced the ripple artifacts. The NPS of DE–VM–VDSR with BF showed the lowest noise characteristics in the high-frequency region (~0.8 cycles/mm). The DE–VM–VDSR without BF yielded an improved resolution relative to that of the conventional reconstruction algorithms for radial MTF analysis (0.2–0.3 cycles/mm). Finally, based on the overall image quality, DE–VM–VDSR with BF improved the contrast and reduced the high-frequency ripple artifacts and noise.
format Online
Article
Text
id pubmed-7774945
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-77749452021-01-11 Improved digital chest tomosynthesis image quality by use of a projection-based dual-energy virtual monochromatic convolutional neural network with super resolution Gomi, Tsutomu Hara, Hidetake Watanabe, Yusuke Mizukami, Shinya PLoS One Research Article We developed a novel dual-energy (DE) virtual monochromatic (VM) very-deep super-resolution (VDSR) method with an unsharp masking reconstruction algorithm (DE–VM–VDSR) that uses projection data to improve the nodule contrast and reduce ripple artifacts during chest digital tomosynthesis (DT). For estimating the residual errors from high-resolution and multiscale VM images from the projection space, the DE–VM–VDSR algorithm employs a training network (mini-batch stochastic gradient-descent algorithm with momentum) and a hybrid super-resolution (SR) image [simultaneous algebraic reconstruction technique (SART) total-variation (TV) first-iterative shrinkage–thresholding algorithm (FISTA); SART–TV–FISTA] that involves subjective reconstruction with bilateral filtering (BF) [DE–VM–VDSR with BF]. DE-DT imaging was accomplished by pulsed X-ray exposures rapidly switched between low (60 kV, 37 projection) and high (120 kV, 37 projection) tube-potential kVp by employing a 40° swing angle. This was followed by comparison of images obtained employing the conventional polychromatic filtered backprojection (FBP), SART, SART–TV–FISTA, and DE–VM–SART–TV–FISTA algorithms. The improvements in contrast, ripple artifacts, and resolution were compared using the signal-difference-to-noise ratio (SDNR), Gumbel distribution of the largest variations, radial modulation transfer function (radial MTF) for a chest phantom with simulated ground-glass opacity (GGO) nodules, and noise power spectrum (NPS) for uniform water phantom. The novel DE–VM–VDSR with BF improved the overall performance in terms of SDNR (DE–VM–VDSR with BF: 0.1603, without BF: 0.1517; FBP: 0.0521; SART: 0.0645; SART–TV–FISTA: 0.0984; and DE–VM–SART–TV–FISTA: 0.1004), obtained a Gumbel distribution that yielded good images showing the type of simulated GGO nodules used in the chest phantom, and reduced the ripple artifacts. The NPS of DE–VM–VDSR with BF showed the lowest noise characteristics in the high-frequency region (~0.8 cycles/mm). The DE–VM–VDSR without BF yielded an improved resolution relative to that of the conventional reconstruction algorithms for radial MTF analysis (0.2–0.3 cycles/mm). Finally, based on the overall image quality, DE–VM–VDSR with BF improved the contrast and reduced the high-frequency ripple artifacts and noise. Public Library of Science 2020-12-31 /pmc/articles/PMC7774945/ /pubmed/33382766 http://dx.doi.org/10.1371/journal.pone.0244745 Text en © 2020 Gomi et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Gomi, Tsutomu
Hara, Hidetake
Watanabe, Yusuke
Mizukami, Shinya
Improved digital chest tomosynthesis image quality by use of a projection-based dual-energy virtual monochromatic convolutional neural network with super resolution
title Improved digital chest tomosynthesis image quality by use of a projection-based dual-energy virtual monochromatic convolutional neural network with super resolution
title_full Improved digital chest tomosynthesis image quality by use of a projection-based dual-energy virtual monochromatic convolutional neural network with super resolution
title_fullStr Improved digital chest tomosynthesis image quality by use of a projection-based dual-energy virtual monochromatic convolutional neural network with super resolution
title_full_unstemmed Improved digital chest tomosynthesis image quality by use of a projection-based dual-energy virtual monochromatic convolutional neural network with super resolution
title_short Improved digital chest tomosynthesis image quality by use of a projection-based dual-energy virtual monochromatic convolutional neural network with super resolution
title_sort improved digital chest tomosynthesis image quality by use of a projection-based dual-energy virtual monochromatic convolutional neural network with super resolution
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7774945/
https://www.ncbi.nlm.nih.gov/pubmed/33382766
http://dx.doi.org/10.1371/journal.pone.0244745
work_keys_str_mv AT gomitsutomu improveddigitalchesttomosynthesisimagequalitybyuseofaprojectionbaseddualenergyvirtualmonochromaticconvolutionalneuralnetworkwithsuperresolution
AT harahidetake improveddigitalchesttomosynthesisimagequalitybyuseofaprojectionbaseddualenergyvirtualmonochromaticconvolutionalneuralnetworkwithsuperresolution
AT watanabeyusuke improveddigitalchesttomosynthesisimagequalitybyuseofaprojectionbaseddualenergyvirtualmonochromaticconvolutionalneuralnetworkwithsuperresolution
AT mizukamishinya improveddigitalchesttomosynthesisimagequalitybyuseofaprojectionbaseddualenergyvirtualmonochromaticconvolutionalneuralnetworkwithsuperresolution