Cargando…
Concomitant Rupture of Extensor Pollicis Longus and Index Extensor Tendons following Distal Radius Plating—Report of Two Cases and Their Clinical Implication for Tendon Transfer Surgery
Extensor indicis proprius (EIP) tendon transfer is a standard operation for restoration of the thumb extension following rupture of extensor pollicis longus (EPL). In its standard form often the EIP is transferred to the EPL without inspection of the extensor tendons in the fourth compartment and it...
Autores principales: | Bhardwaj, Praveen, Varadharajan, Vigneswaran, Sabapathy, S Raja |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Thieme Medical and Scientific Publishers Pvt. Ltd.
2020
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7775254/ https://www.ncbi.nlm.nih.gov/pubmed/33402780 http://dx.doi.org/10.1055/s-0040-1721859 |