Cargando…

Clinical outcomes of ultrathin strut biodegradable polymer-coated everolimus-eluting stent in patients with coronary artery disease

BACKGROUND: Evermine 50™ (Meril Life Sciences Pvt. Ltd., India) everolimus-eluting stent system (EES) is a novel ultrathin strut (50 µm) cobalt-chromium coronary drug-eluting stent (DES) platform with biodegradable polymer coating. The Evermine 50 EES-KLES study aimed to evaluate the Evermine 50 EES...

Descripción completa

Detalles Bibliográficos
Autores principales: Patted, Suresh V., Thakkar, Ashok S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Isfahan Cardiovascular Research Center, Isfahan University of Medical Sciences 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7778515/
https://www.ncbi.nlm.nih.gov/pubmed/33447258
http://dx.doi.org/10.22122/arya.v16i3.1827
_version_ 1783631143326711808
author Patted, Suresh V.
Thakkar, Ashok S.
author_facet Patted, Suresh V.
Thakkar, Ashok S.
author_sort Patted, Suresh V.
collection PubMed
description BACKGROUND: Evermine 50™ (Meril Life Sciences Pvt. Ltd., India) everolimus-eluting stent system (EES) is a novel ultrathin strut (50 µm) cobalt-chromium coronary drug-eluting stent (DES) platform with biodegradable polymer coating. The Evermine 50 EES-KLES study aimed to evaluate the Evermine 50 EES in terms of 24-month clinical safety and performance in patients with coronary artery disease (CAD). METHODS: This retrospective study consisted of 171 patients (258 lesions) implanted with Evermine 50 EES for managing CAD. We analyzed the major adverse cardiac events (MACE) incidence, defined as a composite of cardiac death, myocardial infarction, and ischemia-driven target lesion revascularization (ID-TLR) at 6-, 12-, and 24-month follow-up. RESULTS: A total of 171 patients were included with a mean age of 57.85 ± 10.05 years, of which, 139 (81.29%) were men, 69 (40.35%) were hypertensive, and 70 (40.94%) were diabetic. The incidence of MACE was 1 (0.58%), 3 (1.81%), and 4 (2.42%) at 6-, 12-, and 24-month follow-up, respectively. There were three cases (1.82%) of cardiac death and one case (0.61%) of ID-TLR up to 24 months. None of the patients was presented with definite or probable stent thrombosis (ST). CONCLUSION: This study demonstrated that implantation of ultrathin strut Evermine 50 EES resulted in a low rate of incidence of MACE, indicating a favourable clinical safety and performance profile of Evermine 50 EES in patients with CAD [Clinical Trials Registry-India (CTRI) Number: CTRI/2017/09/009939)].
format Online
Article
Text
id pubmed-7778515
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Isfahan Cardiovascular Research Center, Isfahan University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-77785152021-01-13 Clinical outcomes of ultrathin strut biodegradable polymer-coated everolimus-eluting stent in patients with coronary artery disease Patted, Suresh V. Thakkar, Ashok S. ARYA Atheroscler Original Article BACKGROUND: Evermine 50™ (Meril Life Sciences Pvt. Ltd., India) everolimus-eluting stent system (EES) is a novel ultrathin strut (50 µm) cobalt-chromium coronary drug-eluting stent (DES) platform with biodegradable polymer coating. The Evermine 50 EES-KLES study aimed to evaluate the Evermine 50 EES in terms of 24-month clinical safety and performance in patients with coronary artery disease (CAD). METHODS: This retrospective study consisted of 171 patients (258 lesions) implanted with Evermine 50 EES for managing CAD. We analyzed the major adverse cardiac events (MACE) incidence, defined as a composite of cardiac death, myocardial infarction, and ischemia-driven target lesion revascularization (ID-TLR) at 6-, 12-, and 24-month follow-up. RESULTS: A total of 171 patients were included with a mean age of 57.85 ± 10.05 years, of which, 139 (81.29%) were men, 69 (40.35%) were hypertensive, and 70 (40.94%) were diabetic. The incidence of MACE was 1 (0.58%), 3 (1.81%), and 4 (2.42%) at 6-, 12-, and 24-month follow-up, respectively. There were three cases (1.82%) of cardiac death and one case (0.61%) of ID-TLR up to 24 months. None of the patients was presented with definite or probable stent thrombosis (ST). CONCLUSION: This study demonstrated that implantation of ultrathin strut Evermine 50 EES resulted in a low rate of incidence of MACE, indicating a favourable clinical safety and performance profile of Evermine 50 EES in patients with CAD [Clinical Trials Registry-India (CTRI) Number: CTRI/2017/09/009939)]. Isfahan Cardiovascular Research Center, Isfahan University of Medical Sciences 2020-05 /pmc/articles/PMC7778515/ /pubmed/33447258 http://dx.doi.org/10.22122/arya.v16i3.1827 Text en © 2020 Isfahan Cardiovascular Research Center & Isfahan University of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0/ This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.
spellingShingle Original Article
Patted, Suresh V.
Thakkar, Ashok S.
Clinical outcomes of ultrathin strut biodegradable polymer-coated everolimus-eluting stent in patients with coronary artery disease
title Clinical outcomes of ultrathin strut biodegradable polymer-coated everolimus-eluting stent in patients with coronary artery disease
title_full Clinical outcomes of ultrathin strut biodegradable polymer-coated everolimus-eluting stent in patients with coronary artery disease
title_fullStr Clinical outcomes of ultrathin strut biodegradable polymer-coated everolimus-eluting stent in patients with coronary artery disease
title_full_unstemmed Clinical outcomes of ultrathin strut biodegradable polymer-coated everolimus-eluting stent in patients with coronary artery disease
title_short Clinical outcomes of ultrathin strut biodegradable polymer-coated everolimus-eluting stent in patients with coronary artery disease
title_sort clinical outcomes of ultrathin strut biodegradable polymer-coated everolimus-eluting stent in patients with coronary artery disease
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7778515/
https://www.ncbi.nlm.nih.gov/pubmed/33447258
http://dx.doi.org/10.22122/arya.v16i3.1827
work_keys_str_mv AT pattedsureshv clinicaloutcomesofultrathinstrutbiodegradablepolymercoatedeverolimuselutingstentinpatientswithcoronaryarterydisease
AT thakkarashoks clinicaloutcomesofultrathinstrutbiodegradablepolymercoatedeverolimuselutingstentinpatientswithcoronaryarterydisease