Cargando…

Visian(®) ICLV4c™ and Artiflex(®): Comparative Analysis with the HD Analyser(TM) and Integration with Subjective Performance and Anatomical Parameters

PURPOSE: To analyze and compare the mid-term objective and subjective performance of two phakic intraocular lenses (PIOLs) – Visian(®) ICL™ V4c and Artiflex(®) and to correlate those results with anatomical parameters. PATIENTS AND METHODS: Observational retrospective study including thirty patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Baptista, Pedro Manuel, Monteiro, Sílvia, Abreu, Ana Carolina, Poças, João, José, Diana, Lume, Miguel, Pinto, Maria do Céu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7779300/
https://www.ncbi.nlm.nih.gov/pubmed/33408456
http://dx.doi.org/10.2147/OPTH.S290611
_version_ 1783631305879060480
author Baptista, Pedro Manuel
Monteiro, Sílvia
Abreu, Ana Carolina
Poças, João
José, Diana
Lume, Miguel
Pinto, Maria do Céu
author_facet Baptista, Pedro Manuel
Monteiro, Sílvia
Abreu, Ana Carolina
Poças, João
José, Diana
Lume, Miguel
Pinto, Maria do Céu
author_sort Baptista, Pedro Manuel
collection PubMed
description PURPOSE: To analyze and compare the mid-term objective and subjective performance of two phakic intraocular lenses (PIOLs) – Visian(®) ICL™ V4c and Artiflex(®) and to correlate those results with anatomical parameters. PATIENTS AND METHODS: Observational retrospective study including thirty patients (15 for each PIOL) randomly selected from those who underwent bilateral implantation of one of the PIOLs (60 eyes were analysed). Uncorrected and corrected distance visual acuities (UDVA and CDVA), anterior chamber structural parameters, and corneal endothelial cells density and morphology were evaluated. Quality of vision was assessed both subjectively with a questionnaire, and objectively using a double-pass technology optical quality analysis system. RESULTS: At the end of follow-up the Artiflex(®) group showed better UDVA (0.95±0.11 vs 0.99±0.05, p=0.027) and higher proportion of eyes reaching at least 20/20 (28/30 vs 18/30, p=0.005). Excellent and similar objective scatter index (1.79±0.9 vs 2.14±1.6, p=0.306) and modular transfer function cutoff frequency (26.91±9.2 vs 26.51±11.9, p=0.784) results were achieved in the HD Analyzer(®) and the questionnaire showed comparable high Satisfaction (55.7±3.5 vs 54.3±5.4, p=0.386) and low Dysphotopsia Scores (3.1±1.8 vs 2.1±2.2, p=0.213). The ICL group showed inferior anterior chamber volume (p<0.001), and angle (p<0.001) and superior pupillary diameter (p=0.007). Minimum follow-up was 24 months. CONCLUSION: Both the Visian(®) ICLV4c™ and the Artiflex(®) showed excellent optical performance through the HD Analyzer(TM) technology, translated in high patient satisfaction. Overall, both PIOLs showed similar safety, predictability, stability and effectiveness of for the reduction of high sphero-cylindrical refractive errors, despite better UDVA results with the Artiflex(®).
format Online
Article
Text
id pubmed-7779300
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-77793002021-01-05 Visian(®) ICLV4c™ and Artiflex(®): Comparative Analysis with the HD Analyser(TM) and Integration with Subjective Performance and Anatomical Parameters Baptista, Pedro Manuel Monteiro, Sílvia Abreu, Ana Carolina Poças, João José, Diana Lume, Miguel Pinto, Maria do Céu Clin Ophthalmol Original Research PURPOSE: To analyze and compare the mid-term objective and subjective performance of two phakic intraocular lenses (PIOLs) – Visian(®) ICL™ V4c and Artiflex(®) and to correlate those results with anatomical parameters. PATIENTS AND METHODS: Observational retrospective study including thirty patients (15 for each PIOL) randomly selected from those who underwent bilateral implantation of one of the PIOLs (60 eyes were analysed). Uncorrected and corrected distance visual acuities (UDVA and CDVA), anterior chamber structural parameters, and corneal endothelial cells density and morphology were evaluated. Quality of vision was assessed both subjectively with a questionnaire, and objectively using a double-pass technology optical quality analysis system. RESULTS: At the end of follow-up the Artiflex(®) group showed better UDVA (0.95±0.11 vs 0.99±0.05, p=0.027) and higher proportion of eyes reaching at least 20/20 (28/30 vs 18/30, p=0.005). Excellent and similar objective scatter index (1.79±0.9 vs 2.14±1.6, p=0.306) and modular transfer function cutoff frequency (26.91±9.2 vs 26.51±11.9, p=0.784) results were achieved in the HD Analyzer(®) and the questionnaire showed comparable high Satisfaction (55.7±3.5 vs 54.3±5.4, p=0.386) and low Dysphotopsia Scores (3.1±1.8 vs 2.1±2.2, p=0.213). The ICL group showed inferior anterior chamber volume (p<0.001), and angle (p<0.001) and superior pupillary diameter (p=0.007). Minimum follow-up was 24 months. CONCLUSION: Both the Visian(®) ICLV4c™ and the Artiflex(®) showed excellent optical performance through the HD Analyzer(TM) technology, translated in high patient satisfaction. Overall, both PIOLs showed similar safety, predictability, stability and effectiveness of for the reduction of high sphero-cylindrical refractive errors, despite better UDVA results with the Artiflex(®). Dove 2020-12-30 /pmc/articles/PMC7779300/ /pubmed/33408456 http://dx.doi.org/10.2147/OPTH.S290611 Text en © 2020 Baptista et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Baptista, Pedro Manuel
Monteiro, Sílvia
Abreu, Ana Carolina
Poças, João
José, Diana
Lume, Miguel
Pinto, Maria do Céu
Visian(®) ICLV4c™ and Artiflex(®): Comparative Analysis with the HD Analyser(TM) and Integration with Subjective Performance and Anatomical Parameters
title Visian(®) ICLV4c™ and Artiflex(®): Comparative Analysis with the HD Analyser(TM) and Integration with Subjective Performance and Anatomical Parameters
title_full Visian(®) ICLV4c™ and Artiflex(®): Comparative Analysis with the HD Analyser(TM) and Integration with Subjective Performance and Anatomical Parameters
title_fullStr Visian(®) ICLV4c™ and Artiflex(®): Comparative Analysis with the HD Analyser(TM) and Integration with Subjective Performance and Anatomical Parameters
title_full_unstemmed Visian(®) ICLV4c™ and Artiflex(®): Comparative Analysis with the HD Analyser(TM) and Integration with Subjective Performance and Anatomical Parameters
title_short Visian(®) ICLV4c™ and Artiflex(®): Comparative Analysis with the HD Analyser(TM) and Integration with Subjective Performance and Anatomical Parameters
title_sort visian(®) iclv4c™ and artiflex(®): comparative analysis with the hd analyser(tm) and integration with subjective performance and anatomical parameters
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7779300/
https://www.ncbi.nlm.nih.gov/pubmed/33408456
http://dx.doi.org/10.2147/OPTH.S290611
work_keys_str_mv AT baptistapedromanuel visianiclv4candartiflexcomparativeanalysiswiththehdanalysertmandintegrationwithsubjectiveperformanceandanatomicalparameters
AT monteirosilvia visianiclv4candartiflexcomparativeanalysiswiththehdanalysertmandintegrationwithsubjectiveperformanceandanatomicalparameters
AT abreuanacarolina visianiclv4candartiflexcomparativeanalysiswiththehdanalysertmandintegrationwithsubjectiveperformanceandanatomicalparameters
AT pocasjoao visianiclv4candartiflexcomparativeanalysiswiththehdanalysertmandintegrationwithsubjectiveperformanceandanatomicalparameters
AT josediana visianiclv4candartiflexcomparativeanalysiswiththehdanalysertmandintegrationwithsubjectiveperformanceandanatomicalparameters
AT lumemiguel visianiclv4candartiflexcomparativeanalysiswiththehdanalysertmandintegrationwithsubjectiveperformanceandanatomicalparameters
AT pintomariadoceu visianiclv4candartiflexcomparativeanalysiswiththehdanalysertmandintegrationwithsubjectiveperformanceandanatomicalparameters