Visian(®) ICLV4c™ and Artiflex(®): Comparative Analysis with the HD Analyser(TM) and Integration with Subjective Performance and Anatomical Parameters
PURPOSE: To analyze and compare the mid-term objective and subjective performance of two phakic intraocular lenses (PIOLs) – Visian(®) ICL™ V4c and Artiflex(®) and to correlate those results with anatomical parameters. PATIENTS AND METHODS: Observational retrospective study including thirty patients...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7779300/ https://www.ncbi.nlm.nih.gov/pubmed/33408456 http://dx.doi.org/10.2147/OPTH.S290611 |
_version_ | 1783631305879060480 |
---|---|
author | Baptista, Pedro Manuel Monteiro, Sílvia Abreu, Ana Carolina Poças, João José, Diana Lume, Miguel Pinto, Maria do Céu |
author_facet | Baptista, Pedro Manuel Monteiro, Sílvia Abreu, Ana Carolina Poças, João José, Diana Lume, Miguel Pinto, Maria do Céu |
author_sort | Baptista, Pedro Manuel |
collection | PubMed |
description | PURPOSE: To analyze and compare the mid-term objective and subjective performance of two phakic intraocular lenses (PIOLs) – Visian(®) ICL™ V4c and Artiflex(®) and to correlate those results with anatomical parameters. PATIENTS AND METHODS: Observational retrospective study including thirty patients (15 for each PIOL) randomly selected from those who underwent bilateral implantation of one of the PIOLs (60 eyes were analysed). Uncorrected and corrected distance visual acuities (UDVA and CDVA), anterior chamber structural parameters, and corneal endothelial cells density and morphology were evaluated. Quality of vision was assessed both subjectively with a questionnaire, and objectively using a double-pass technology optical quality analysis system. RESULTS: At the end of follow-up the Artiflex(®) group showed better UDVA (0.95±0.11 vs 0.99±0.05, p=0.027) and higher proportion of eyes reaching at least 20/20 (28/30 vs 18/30, p=0.005). Excellent and similar objective scatter index (1.79±0.9 vs 2.14±1.6, p=0.306) and modular transfer function cutoff frequency (26.91±9.2 vs 26.51±11.9, p=0.784) results were achieved in the HD Analyzer(®) and the questionnaire showed comparable high Satisfaction (55.7±3.5 vs 54.3±5.4, p=0.386) and low Dysphotopsia Scores (3.1±1.8 vs 2.1±2.2, p=0.213). The ICL group showed inferior anterior chamber volume (p<0.001), and angle (p<0.001) and superior pupillary diameter (p=0.007). Minimum follow-up was 24 months. CONCLUSION: Both the Visian(®) ICLV4c™ and the Artiflex(®) showed excellent optical performance through the HD Analyzer(TM) technology, translated in high patient satisfaction. Overall, both PIOLs showed similar safety, predictability, stability and effectiveness of for the reduction of high sphero-cylindrical refractive errors, despite better UDVA results with the Artiflex(®). |
format | Online Article Text |
id | pubmed-7779300 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-77793002021-01-05 Visian(®) ICLV4c™ and Artiflex(®): Comparative Analysis with the HD Analyser(TM) and Integration with Subjective Performance and Anatomical Parameters Baptista, Pedro Manuel Monteiro, Sílvia Abreu, Ana Carolina Poças, João José, Diana Lume, Miguel Pinto, Maria do Céu Clin Ophthalmol Original Research PURPOSE: To analyze and compare the mid-term objective and subjective performance of two phakic intraocular lenses (PIOLs) – Visian(®) ICL™ V4c and Artiflex(®) and to correlate those results with anatomical parameters. PATIENTS AND METHODS: Observational retrospective study including thirty patients (15 for each PIOL) randomly selected from those who underwent bilateral implantation of one of the PIOLs (60 eyes were analysed). Uncorrected and corrected distance visual acuities (UDVA and CDVA), anterior chamber structural parameters, and corneal endothelial cells density and morphology were evaluated. Quality of vision was assessed both subjectively with a questionnaire, and objectively using a double-pass technology optical quality analysis system. RESULTS: At the end of follow-up the Artiflex(®) group showed better UDVA (0.95±0.11 vs 0.99±0.05, p=0.027) and higher proportion of eyes reaching at least 20/20 (28/30 vs 18/30, p=0.005). Excellent and similar objective scatter index (1.79±0.9 vs 2.14±1.6, p=0.306) and modular transfer function cutoff frequency (26.91±9.2 vs 26.51±11.9, p=0.784) results were achieved in the HD Analyzer(®) and the questionnaire showed comparable high Satisfaction (55.7±3.5 vs 54.3±5.4, p=0.386) and low Dysphotopsia Scores (3.1±1.8 vs 2.1±2.2, p=0.213). The ICL group showed inferior anterior chamber volume (p<0.001), and angle (p<0.001) and superior pupillary diameter (p=0.007). Minimum follow-up was 24 months. CONCLUSION: Both the Visian(®) ICLV4c™ and the Artiflex(®) showed excellent optical performance through the HD Analyzer(TM) technology, translated in high patient satisfaction. Overall, both PIOLs showed similar safety, predictability, stability and effectiveness of for the reduction of high sphero-cylindrical refractive errors, despite better UDVA results with the Artiflex(®). Dove 2020-12-30 /pmc/articles/PMC7779300/ /pubmed/33408456 http://dx.doi.org/10.2147/OPTH.S290611 Text en © 2020 Baptista et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Baptista, Pedro Manuel Monteiro, Sílvia Abreu, Ana Carolina Poças, João José, Diana Lume, Miguel Pinto, Maria do Céu Visian(®) ICLV4c™ and Artiflex(®): Comparative Analysis with the HD Analyser(TM) and Integration with Subjective Performance and Anatomical Parameters |
title | Visian(®) ICLV4c™ and Artiflex(®): Comparative Analysis with the HD Analyser(TM) and Integration with Subjective Performance and Anatomical Parameters |
title_full | Visian(®) ICLV4c™ and Artiflex(®): Comparative Analysis with the HD Analyser(TM) and Integration with Subjective Performance and Anatomical Parameters |
title_fullStr | Visian(®) ICLV4c™ and Artiflex(®): Comparative Analysis with the HD Analyser(TM) and Integration with Subjective Performance and Anatomical Parameters |
title_full_unstemmed | Visian(®) ICLV4c™ and Artiflex(®): Comparative Analysis with the HD Analyser(TM) and Integration with Subjective Performance and Anatomical Parameters |
title_short | Visian(®) ICLV4c™ and Artiflex(®): Comparative Analysis with the HD Analyser(TM) and Integration with Subjective Performance and Anatomical Parameters |
title_sort | visian(®) iclv4c™ and artiflex(®): comparative analysis with the hd analyser(tm) and integration with subjective performance and anatomical parameters |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7779300/ https://www.ncbi.nlm.nih.gov/pubmed/33408456 http://dx.doi.org/10.2147/OPTH.S290611 |
work_keys_str_mv | AT baptistapedromanuel visianiclv4candartiflexcomparativeanalysiswiththehdanalysertmandintegrationwithsubjectiveperformanceandanatomicalparameters AT monteirosilvia visianiclv4candartiflexcomparativeanalysiswiththehdanalysertmandintegrationwithsubjectiveperformanceandanatomicalparameters AT abreuanacarolina visianiclv4candartiflexcomparativeanalysiswiththehdanalysertmandintegrationwithsubjectiveperformanceandanatomicalparameters AT pocasjoao visianiclv4candartiflexcomparativeanalysiswiththehdanalysertmandintegrationwithsubjectiveperformanceandanatomicalparameters AT josediana visianiclv4candartiflexcomparativeanalysiswiththehdanalysertmandintegrationwithsubjectiveperformanceandanatomicalparameters AT lumemiguel visianiclv4candartiflexcomparativeanalysiswiththehdanalysertmandintegrationwithsubjectiveperformanceandanatomicalparameters AT pintomariadoceu visianiclv4candartiflexcomparativeanalysiswiththehdanalysertmandintegrationwithsubjectiveperformanceandanatomicalparameters |