Cargando…

Related factors for preserving firefighter's pulmonary function

BACKGROUND: Firefighters are constantly exposed to harmful substances in the respiratory tract and require management measures. We comprehensively compared factors affecting the lung function of firefighters to identify management measures that can reduce the deterioration of lung function. METHODS:...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Seonggyu, Jeon, Ye-eun, Ryu, Hyeseung, Lee, Mi-Young, Chung, Insung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Occupational & Environmental Medicine 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7779844/
https://www.ncbi.nlm.nih.gov/pubmed/34754461
http://dx.doi.org/10.35371/aoem.2020.32.e40
_version_ 1783631411192791040
author Kim, Seonggyu
Jeon, Ye-eun
Ryu, Hyeseung
Lee, Mi-Young
Chung, Insung
author_facet Kim, Seonggyu
Jeon, Ye-eun
Ryu, Hyeseung
Lee, Mi-Young
Chung, Insung
author_sort Kim, Seonggyu
collection PubMed
description BACKGROUND: Firefighters are constantly exposed to harmful substances in the respiratory tract and require management measures. We comprehensively compared factors affecting the lung function of firefighters to identify management measures that can reduce the deterioration of lung function. METHODS: A cross-sectional study was conducted in 1,108 male firefighters. Subjects were surveyed with self-written questionnaires that included a history of smoking, number of workouts per week, work department, and medical history, including diseases that could affect lung function. Body mass index was calculated using an automatic body measurement instrument and body fat, body fat percentage, muscle mass, and skeletal muscle mass were measured using Inbody 770. Based on the body weight obtained from body measurements, skeletal muscle mass height-adjusted skeletal muscle index (hSMI) compared to height was determined. For lung function, forced expiratory volume in one second (FEV(1)), forced vital capacity (FVC), FEV(1)/FVC, and peak expiratory flow (PEF) were measured using a spirometer HI-801. Analysis of variance and independent t-tests were performed for univariate analysis of factors that could affect lung function, and multiple regression analysis was performed for multivariate analysis. RESULTS: When the factors relating lung function were analyzed using regression analysis, FEV(1) was negatively correlated with age, body fat percentage, and duty year, positively with height and hSMI. FVC increased with height and hSMI, decreased with age, body fat percentage, and duty year. FEV(1)/FVC was related with age, height, body fat percentage and working history. Height and muscle mass were analyzed as related factors on PEF. When the analysis was conducted on firefighters who exercised more than 3 times a week, working history had lower relation with FEV(1) and body fat percentage had no relation with FEV(1)/FVC. CONCLUSION: We suggest management measures to reduce body fat percentage and increase skeletal muscle mass to maintain lung function in firefighters.
format Online
Article
Text
id pubmed-7779844
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Korean Society of Occupational & Environmental Medicine
record_format MEDLINE/PubMed
spelling pubmed-77798442021-02-23 Related factors for preserving firefighter's pulmonary function Kim, Seonggyu Jeon, Ye-eun Ryu, Hyeseung Lee, Mi-Young Chung, Insung Ann Occup Environ Med Research Article BACKGROUND: Firefighters are constantly exposed to harmful substances in the respiratory tract and require management measures. We comprehensively compared factors affecting the lung function of firefighters to identify management measures that can reduce the deterioration of lung function. METHODS: A cross-sectional study was conducted in 1,108 male firefighters. Subjects were surveyed with self-written questionnaires that included a history of smoking, number of workouts per week, work department, and medical history, including diseases that could affect lung function. Body mass index was calculated using an automatic body measurement instrument and body fat, body fat percentage, muscle mass, and skeletal muscle mass were measured using Inbody 770. Based on the body weight obtained from body measurements, skeletal muscle mass height-adjusted skeletal muscle index (hSMI) compared to height was determined. For lung function, forced expiratory volume in one second (FEV(1)), forced vital capacity (FVC), FEV(1)/FVC, and peak expiratory flow (PEF) were measured using a spirometer HI-801. Analysis of variance and independent t-tests were performed for univariate analysis of factors that could affect lung function, and multiple regression analysis was performed for multivariate analysis. RESULTS: When the factors relating lung function were analyzed using regression analysis, FEV(1) was negatively correlated with age, body fat percentage, and duty year, positively with height and hSMI. FVC increased with height and hSMI, decreased with age, body fat percentage, and duty year. FEV(1)/FVC was related with age, height, body fat percentage and working history. Height and muscle mass were analyzed as related factors on PEF. When the analysis was conducted on firefighters who exercised more than 3 times a week, working history had lower relation with FEV(1) and body fat percentage had no relation with FEV(1)/FVC. CONCLUSION: We suggest management measures to reduce body fat percentage and increase skeletal muscle mass to maintain lung function in firefighters. Korean Society of Occupational & Environmental Medicine 2020-12-18 /pmc/articles/PMC7779844/ /pubmed/34754461 http://dx.doi.org/10.35371/aoem.2020.32.e40 Text en Copyright © 2020 Korean Society of Occupational & Environmental Medicine https://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Kim, Seonggyu
Jeon, Ye-eun
Ryu, Hyeseung
Lee, Mi-Young
Chung, Insung
Related factors for preserving firefighter's pulmonary function
title Related factors for preserving firefighter's pulmonary function
title_full Related factors for preserving firefighter's pulmonary function
title_fullStr Related factors for preserving firefighter's pulmonary function
title_full_unstemmed Related factors for preserving firefighter's pulmonary function
title_short Related factors for preserving firefighter's pulmonary function
title_sort related factors for preserving firefighter's pulmonary function
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7779844/
https://www.ncbi.nlm.nih.gov/pubmed/34754461
http://dx.doi.org/10.35371/aoem.2020.32.e40
work_keys_str_mv AT kimseonggyu relatedfactorsforpreservingfirefighterspulmonaryfunction
AT jeonyeeun relatedfactorsforpreservingfirefighterspulmonaryfunction
AT ryuhyeseung relatedfactorsforpreservingfirefighterspulmonaryfunction
AT leemiyoung relatedfactorsforpreservingfirefighterspulmonaryfunction
AT chunginsung relatedfactorsforpreservingfirefighterspulmonaryfunction