3D Heads-Up Display vs. Standard Operating Microscope Vitrectomy for Rhegmatogenous Retinal Detachment

Purpose: To assess the efficacy and outcomes of 23-gauge vitreoretinal surgery for rhegmatogenous retinal detachment using a three-dimensional heads-up display (3D HUD) surgical platform as compared to a standard operating microscope (SOM) setting. Design: Retrospective cohort study. Participants: O...

Descripción completa

Detalles Bibliográficos
Autores principales: Asani, Ben, Siedlecki, Jakob, Schworm, Benedikt, Mayer, Wolfgang J., Kreutzer, Thomas C., Luft, Nikolaus, Priglinger, Siegfried G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7782350/
https://www.ncbi.nlm.nih.gov/pubmed/33415120
http://dx.doi.org/10.3389/fmed.2020.615515
_version_ 1783631882034872320
author Asani, Ben
Siedlecki, Jakob
Schworm, Benedikt
Mayer, Wolfgang J.
Kreutzer, Thomas C.
Luft, Nikolaus
Priglinger, Siegfried G.
author_facet Asani, Ben
Siedlecki, Jakob
Schworm, Benedikt
Mayer, Wolfgang J.
Kreutzer, Thomas C.
Luft, Nikolaus
Priglinger, Siegfried G.
author_sort Asani, Ben
collection PubMed
description Purpose: To assess the efficacy and outcomes of 23-gauge vitreoretinal surgery for rhegmatogenous retinal detachment using a three-dimensional heads-up display (3D HUD) surgical platform as compared to a standard operating microscope (SOM) setting. Design: Retrospective cohort study. Participants: One hundred and forty consecutive eyes of 140 patients with primary retinal detachment. Methods: All eyes underwent 23-gauge pars plana vitrectomy for primary retinal detachment using either a 3D HUD (NGENUITY; Alcon Inc., Fort Worth, Texas, USA; n = 70 eyes) or a SOM setting (n = 70 eyes); in cases of significant cataract, additional phacoemulsification with intraocular lens (IOL) implantation was performed. Minimum follow-up was 2 months. Main Outcome Measures: Primary retinal reattachment rate, rate of proliferative vitreoretinopathy (PVR), best-corrected visual acuity (BCVA), and duration of surgery. Results: There were 70 eyes each in the 3D HUD and the SOM group. Both groups did not differ concerning age (p = 0.70), extent of retinal detachment (p = 0.07), number of retinal tears (p = 0.40), macular involvement (p = 0.99), and preoperative BCVA (p = 0.99). Postoperatively, 3D HUD and SOM were comparable concerning the primary retinal reattachment rate (88.6 vs. 94.3%; p = 0.37), the development of postoperative PVR (12.9% vs. 7.1%; p = 0.40) and final BCVA (0.26 ± 0.40 vs. 0.21 ± 0.38 logMAR; p = 0.99). Duration of surgery was significantly longer in the 3D HUD group (66.2 ± 16.5 vs. 61.2 ± 17.1 min; p = 0.04), an effect which however vanished after a “learning curve” of the first 35 eyes (p = 0.49). Conclusions: On par results to a conventional operating microscope can be achieved with a 3D HUD setting when performing 23-gauge vitreoretinal surgery for rhegmatogenous retinal detachment, including the primary retinal reattachment rate, the incidence of postoperative PVR and final BCVA. However, duration of surgery might initially be slightly longer with 3D HUD, suggesting the effect of a learning curve.
format Online
Article
Text
id pubmed-7782350
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-77823502021-01-06 3D Heads-Up Display vs. Standard Operating Microscope Vitrectomy for Rhegmatogenous Retinal Detachment Asani, Ben Siedlecki, Jakob Schworm, Benedikt Mayer, Wolfgang J. Kreutzer, Thomas C. Luft, Nikolaus Priglinger, Siegfried G. Front Med (Lausanne) Medicine Purpose: To assess the efficacy and outcomes of 23-gauge vitreoretinal surgery for rhegmatogenous retinal detachment using a three-dimensional heads-up display (3D HUD) surgical platform as compared to a standard operating microscope (SOM) setting. Design: Retrospective cohort study. Participants: One hundred and forty consecutive eyes of 140 patients with primary retinal detachment. Methods: All eyes underwent 23-gauge pars plana vitrectomy for primary retinal detachment using either a 3D HUD (NGENUITY; Alcon Inc., Fort Worth, Texas, USA; n = 70 eyes) or a SOM setting (n = 70 eyes); in cases of significant cataract, additional phacoemulsification with intraocular lens (IOL) implantation was performed. Minimum follow-up was 2 months. Main Outcome Measures: Primary retinal reattachment rate, rate of proliferative vitreoretinopathy (PVR), best-corrected visual acuity (BCVA), and duration of surgery. Results: There were 70 eyes each in the 3D HUD and the SOM group. Both groups did not differ concerning age (p = 0.70), extent of retinal detachment (p = 0.07), number of retinal tears (p = 0.40), macular involvement (p = 0.99), and preoperative BCVA (p = 0.99). Postoperatively, 3D HUD and SOM were comparable concerning the primary retinal reattachment rate (88.6 vs. 94.3%; p = 0.37), the development of postoperative PVR (12.9% vs. 7.1%; p = 0.40) and final BCVA (0.26 ± 0.40 vs. 0.21 ± 0.38 logMAR; p = 0.99). Duration of surgery was significantly longer in the 3D HUD group (66.2 ± 16.5 vs. 61.2 ± 17.1 min; p = 0.04), an effect which however vanished after a “learning curve” of the first 35 eyes (p = 0.49). Conclusions: On par results to a conventional operating microscope can be achieved with a 3D HUD setting when performing 23-gauge vitreoretinal surgery for rhegmatogenous retinal detachment, including the primary retinal reattachment rate, the incidence of postoperative PVR and final BCVA. However, duration of surgery might initially be slightly longer with 3D HUD, suggesting the effect of a learning curve. Frontiers Media S.A. 2020-12-22 /pmc/articles/PMC7782350/ /pubmed/33415120 http://dx.doi.org/10.3389/fmed.2020.615515 Text en Copyright © 2020 Asani, Siedlecki, Schworm, Mayer, Kreutzer, Luft and Priglinger. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Medicine
Asani, Ben
Siedlecki, Jakob
Schworm, Benedikt
Mayer, Wolfgang J.
Kreutzer, Thomas C.
Luft, Nikolaus
Priglinger, Siegfried G.
3D Heads-Up Display vs. Standard Operating Microscope Vitrectomy for Rhegmatogenous Retinal Detachment
title 3D Heads-Up Display vs. Standard Operating Microscope Vitrectomy for Rhegmatogenous Retinal Detachment
title_full 3D Heads-Up Display vs. Standard Operating Microscope Vitrectomy for Rhegmatogenous Retinal Detachment
title_fullStr 3D Heads-Up Display vs. Standard Operating Microscope Vitrectomy for Rhegmatogenous Retinal Detachment
title_full_unstemmed 3D Heads-Up Display vs. Standard Operating Microscope Vitrectomy for Rhegmatogenous Retinal Detachment
title_short 3D Heads-Up Display vs. Standard Operating Microscope Vitrectomy for Rhegmatogenous Retinal Detachment
title_sort 3d heads-up display vs. standard operating microscope vitrectomy for rhegmatogenous retinal detachment
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7782350/
https://www.ncbi.nlm.nih.gov/pubmed/33415120
http://dx.doi.org/10.3389/fmed.2020.615515
work_keys_str_mv AT asaniben 3dheadsupdisplayvsstandardoperatingmicroscopevitrectomyforrhegmatogenousretinaldetachment
AT siedleckijakob 3dheadsupdisplayvsstandardoperatingmicroscopevitrectomyforrhegmatogenousretinaldetachment
AT schwormbenedikt 3dheadsupdisplayvsstandardoperatingmicroscopevitrectomyforrhegmatogenousretinaldetachment
AT mayerwolfgangj 3dheadsupdisplayvsstandardoperatingmicroscopevitrectomyforrhegmatogenousretinaldetachment
AT kreutzerthomasc 3dheadsupdisplayvsstandardoperatingmicroscopevitrectomyforrhegmatogenousretinaldetachment
AT luftnikolaus 3dheadsupdisplayvsstandardoperatingmicroscopevitrectomyforrhegmatogenousretinaldetachment
AT priglingersiegfriedg 3dheadsupdisplayvsstandardoperatingmicroscopevitrectomyforrhegmatogenousretinaldetachment