Cargando…

Mini-plate versus Kirschner wire internal fixation for treatment of metacarpal and phalangeal fractures

OBJECTIVE: To conduct a meta-analysis to show the associations of perioperative and postoperative outcomes of mini-plate internal fixation (MPIF) versus Kirschner wire internal fixation (KWIF) for treating metacarpal and phalangeal fractures. METHODS: A literature search was performed in PubMed, Web...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Dong, Sun, Kai, Jiang, Wenxue
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7783250/
https://www.ncbi.nlm.nih.gov/pubmed/31826692
http://dx.doi.org/10.1177/0300060519887264
_version_ 1783632075973197824
author Wang, Dong
Sun, Kai
Jiang, Wenxue
author_facet Wang, Dong
Sun, Kai
Jiang, Wenxue
author_sort Wang, Dong
collection PubMed
description OBJECTIVE: To conduct a meta-analysis to show the associations of perioperative and postoperative outcomes of mini-plate internal fixation (MPIF) versus Kirschner wire internal fixation (KWIF) for treating metacarpal and phalangeal fractures. METHODS: A literature search was performed in PubMed, Web of Science, Cochrane Library, and Embase from the earliest date of data collection to April 2018. Studies that compared perioperative and postoperative outcomes of MPIF with those of KWIF in patients with metacarpal and phalangeal fractures were included. RESULTS: Twenty-six articles met the inclusion and exclusion criteria (n = 2029 patients; 1042 with MPIF and 987 with KWIF). MPIF was related to a greater increase in length of surgery, hospital days, excellent and good rate of outcome, short-form health survey-36 score, and flexion and extension range compared with KWIF. MPIF was related to a greater decrease in intraoperative blood loss, finger visual analog scale score, functional exercise time, fracture healing time, incidence of complications, and postoperative infection rate compared with KWIF. CONCLUSIONS: Patients with MPIF have sufficient pressure and strength, and MPIF promotes successful joint fusion and reduces complications of the operation. MPIF is ideal for reduction and stability of patients with metacarpal and phalangeal fractures.
format Online
Article
Text
id pubmed-7783250
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-77832502021-01-13 Mini-plate versus Kirschner wire internal fixation for treatment of metacarpal and phalangeal fractures Wang, Dong Sun, Kai Jiang, Wenxue J Int Med Res Meta-Analysis and Systematic Review OBJECTIVE: To conduct a meta-analysis to show the associations of perioperative and postoperative outcomes of mini-plate internal fixation (MPIF) versus Kirschner wire internal fixation (KWIF) for treating metacarpal and phalangeal fractures. METHODS: A literature search was performed in PubMed, Web of Science, Cochrane Library, and Embase from the earliest date of data collection to April 2018. Studies that compared perioperative and postoperative outcomes of MPIF with those of KWIF in patients with metacarpal and phalangeal fractures were included. RESULTS: Twenty-six articles met the inclusion and exclusion criteria (n = 2029 patients; 1042 with MPIF and 987 with KWIF). MPIF was related to a greater increase in length of surgery, hospital days, excellent and good rate of outcome, short-form health survey-36 score, and flexion and extension range compared with KWIF. MPIF was related to a greater decrease in intraoperative blood loss, finger visual analog scale score, functional exercise time, fracture healing time, incidence of complications, and postoperative infection rate compared with KWIF. CONCLUSIONS: Patients with MPIF have sufficient pressure and strength, and MPIF promotes successful joint fusion and reduces complications of the operation. MPIF is ideal for reduction and stability of patients with metacarpal and phalangeal fractures. SAGE Publications 2019-12-11 /pmc/articles/PMC7783250/ /pubmed/31826692 http://dx.doi.org/10.1177/0300060519887264 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by-nc/4.0/ Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Meta-Analysis and Systematic Review
Wang, Dong
Sun, Kai
Jiang, Wenxue
Mini-plate versus Kirschner wire internal fixation for treatment of metacarpal and phalangeal fractures
title Mini-plate versus Kirschner wire internal fixation for treatment of metacarpal and phalangeal fractures
title_full Mini-plate versus Kirschner wire internal fixation for treatment of metacarpal and phalangeal fractures
title_fullStr Mini-plate versus Kirschner wire internal fixation for treatment of metacarpal and phalangeal fractures
title_full_unstemmed Mini-plate versus Kirschner wire internal fixation for treatment of metacarpal and phalangeal fractures
title_short Mini-plate versus Kirschner wire internal fixation for treatment of metacarpal and phalangeal fractures
title_sort mini-plate versus kirschner wire internal fixation for treatment of metacarpal and phalangeal fractures
topic Meta-Analysis and Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7783250/
https://www.ncbi.nlm.nih.gov/pubmed/31826692
http://dx.doi.org/10.1177/0300060519887264
work_keys_str_mv AT wangdong miniplateversuskirschnerwireinternalfixationfortreatmentofmetacarpalandphalangealfractures
AT sunkai miniplateversuskirschnerwireinternalfixationfortreatmentofmetacarpalandphalangealfractures
AT jiangwenxue miniplateversuskirschnerwireinternalfixationfortreatmentofmetacarpalandphalangealfractures