Cargando…

Femoral trochanteric fracture: PFNA spiral blade placement with the aid of an angler

OBJECTIVE: To investigate the effect of angler-assisted proximal femoral nail antirotation (PFNA) spiral blade fixation in treating femoral trochanteric fractures. METHODS: Patients who underwent angler-assisted PFNA screw blade fixation (angler-assisted group), or conventional internal fixation-int...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Ye, Pan, Keliang, Wang, Gangxiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7783287/
https://www.ncbi.nlm.nih.gov/pubmed/31849249
http://dx.doi.org/10.1177/0300060519890782
_version_ 1783632085042331648
author Yu, Ye
Pan, Keliang
Wang, Gangxiang
author_facet Yu, Ye
Pan, Keliang
Wang, Gangxiang
author_sort Yu, Ye
collection PubMed
description OBJECTIVE: To investigate the effect of angler-assisted proximal femoral nail antirotation (PFNA) spiral blade fixation in treating femoral trochanteric fractures. METHODS: Patients who underwent angler-assisted PFNA screw blade fixation (angler-assisted group), or conventional internal fixation-intramedullary nailing (traditional surgery group) were included. Intraoperative indicators and treatment effects data were retrospectively analysed. RESULTS: Statistically significant differences were observed between the angler-assisted group (n = 27) and traditional surgery group (n = 28) regarding surgery duration (71.24 ± 8.01 min versus 81.50 ± 11.56 min), number of intraoperative fluoroscopy images (7.28 ± 0.91 versus 12.83 ± 1.55), and surgical bleeding volume (88.80 ± 7.98 ml versus 121.11 ± 27.21 ml). Rates of one-time intramedullary pin puncture for internal fixation in the angler-assisted and traditional surgery groups were 92.59% (25/27) and 32.14% (9/28), respectively. At 1 year following surgery, fractures in both groups had healed without internal fixation failure or fracture displacement failure. Harris hip function scores were 90.68 ± 4.23 (angler-assisted group) versus 81.69 ± 5.85 (traditional surgery group). CONCLUSIONS: Angler-assisted intramedullary nailing with PFNA spiral blade provides good spiral blade positioning, low internal fixation failure rate, low fluoroscopy, short surgery time, and low bleeding volume. Hip function was well restored.
format Online
Article
Text
id pubmed-7783287
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-77832872021-01-13 Femoral trochanteric fracture: PFNA spiral blade placement with the aid of an angler Yu, Ye Pan, Keliang Wang, Gangxiang J Int Med Res Retrospective Clinical Research Report OBJECTIVE: To investigate the effect of angler-assisted proximal femoral nail antirotation (PFNA) spiral blade fixation in treating femoral trochanteric fractures. METHODS: Patients who underwent angler-assisted PFNA screw blade fixation (angler-assisted group), or conventional internal fixation-intramedullary nailing (traditional surgery group) were included. Intraoperative indicators and treatment effects data were retrospectively analysed. RESULTS: Statistically significant differences were observed between the angler-assisted group (n = 27) and traditional surgery group (n = 28) regarding surgery duration (71.24 ± 8.01 min versus 81.50 ± 11.56 min), number of intraoperative fluoroscopy images (7.28 ± 0.91 versus 12.83 ± 1.55), and surgical bleeding volume (88.80 ± 7.98 ml versus 121.11 ± 27.21 ml). Rates of one-time intramedullary pin puncture for internal fixation in the angler-assisted and traditional surgery groups were 92.59% (25/27) and 32.14% (9/28), respectively. At 1 year following surgery, fractures in both groups had healed without internal fixation failure or fracture displacement failure. Harris hip function scores were 90.68 ± 4.23 (angler-assisted group) versus 81.69 ± 5.85 (traditional surgery group). CONCLUSIONS: Angler-assisted intramedullary nailing with PFNA spiral blade provides good spiral blade positioning, low internal fixation failure rate, low fluoroscopy, short surgery time, and low bleeding volume. Hip function was well restored. SAGE Publications 2019-12-18 /pmc/articles/PMC7783287/ /pubmed/31849249 http://dx.doi.org/10.1177/0300060519890782 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by-nc/4.0/ Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Retrospective Clinical Research Report
Yu, Ye
Pan, Keliang
Wang, Gangxiang
Femoral trochanteric fracture: PFNA spiral blade placement with the aid of an angler
title Femoral trochanteric fracture: PFNA spiral blade placement with the aid of an angler
title_full Femoral trochanteric fracture: PFNA spiral blade placement with the aid of an angler
title_fullStr Femoral trochanteric fracture: PFNA spiral blade placement with the aid of an angler
title_full_unstemmed Femoral trochanteric fracture: PFNA spiral blade placement with the aid of an angler
title_short Femoral trochanteric fracture: PFNA spiral blade placement with the aid of an angler
title_sort femoral trochanteric fracture: pfna spiral blade placement with the aid of an angler
topic Retrospective Clinical Research Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7783287/
https://www.ncbi.nlm.nih.gov/pubmed/31849249
http://dx.doi.org/10.1177/0300060519890782
work_keys_str_mv AT yuye femoraltrochantericfracturepfnaspiralbladeplacementwiththeaidofanangler
AT pankeliang femoraltrochantericfracturepfnaspiralbladeplacementwiththeaidofanangler
AT wanggangxiang femoraltrochantericfracturepfnaspiralbladeplacementwiththeaidofanangler