Cargando…
Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs
Local anesthetic (LA) injection outside the sheath in epineural or paraneural connective tissue is considered safe practice among regional anesthesiologists. There is limited evidence as to whether neurological complications occur if LA is injected inside the sheath (subepineural - intraneural). We...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Pain Society
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7783848/ https://www.ncbi.nlm.nih.gov/pubmed/33380576 http://dx.doi.org/10.3344/kjp.2021.34.1.132 |
_version_ | 1783632184026857472 |
---|---|
author | Diwan, Sandeep Nair, Abhijit Sancheti, Parag Zundert, André Van |
author_facet | Diwan, Sandeep Nair, Abhijit Sancheti, Parag Zundert, André Van |
author_sort | Diwan, Sandeep |
collection | PubMed |
description | Local anesthetic (LA) injection outside the sheath in epineural or paraneural connective tissue is considered safe practice among regional anesthesiologists. There is limited evidence as to whether neurological complications occur if LA is injected inside the sheath (subepineural - intraneural). We performed ultrasound guided injections at the level of undivided sciatic nerve in four amputated lower limbs. In two specimens, LA was injected in epineural connective tissue (paraneural tissue) and in another two specimens by penetrating the outer nerve sheath (hyperechoic epineurium). Ultrasonography demonstrated an increase in the size of nerve and macroscopic findings revealed fascicular tracings with sub-epineural injections. Limbs were sent for histological analysis in formalin containers. Pathologist performed the analysis which demonstrated an intact perineurium and a breach in the epineurium. We conclude that sub-epineural injections are unsafe and injection should be done in paraneural tissue to ensure safety and avoid unwanted neurological sequelae after the block. |
format | Online Article Text |
id | pubmed-7783848 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | The Korean Pain Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-77838482021-01-11 Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs Diwan, Sandeep Nair, Abhijit Sancheti, Parag Zundert, André Van Korean J Pain Case Report Local anesthetic (LA) injection outside the sheath in epineural or paraneural connective tissue is considered safe practice among regional anesthesiologists. There is limited evidence as to whether neurological complications occur if LA is injected inside the sheath (subepineural - intraneural). We performed ultrasound guided injections at the level of undivided sciatic nerve in four amputated lower limbs. In two specimens, LA was injected in epineural connective tissue (paraneural tissue) and in another two specimens by penetrating the outer nerve sheath (hyperechoic epineurium). Ultrasonography demonstrated an increase in the size of nerve and macroscopic findings revealed fascicular tracings with sub-epineural injections. Limbs were sent for histological analysis in formalin containers. Pathologist performed the analysis which demonstrated an intact perineurium and a breach in the epineurium. We conclude that sub-epineural injections are unsafe and injection should be done in paraneural tissue to ensure safety and avoid unwanted neurological sequelae after the block. The Korean Pain Society 2021-01-01 2021-01-01 /pmc/articles/PMC7783848/ /pubmed/33380576 http://dx.doi.org/10.3344/kjp.2021.34.1.132 Text en © The Korean Pain Society, 2021 This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Diwan, Sandeep Nair, Abhijit Sancheti, Parag Zundert, André Van Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs |
title | Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs |
title_full | Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs |
title_fullStr | Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs |
title_full_unstemmed | Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs |
title_short | Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs |
title_sort | does subepineural injection damage the nerve integrity? a technical report from four amputated limbs |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7783848/ https://www.ncbi.nlm.nih.gov/pubmed/33380576 http://dx.doi.org/10.3344/kjp.2021.34.1.132 |
work_keys_str_mv | AT diwansandeep doessubepineuralinjectiondamagethenerveintegrityatechnicalreportfromfouramputatedlimbs AT nairabhijit doessubepineuralinjectiondamagethenerveintegrityatechnicalreportfromfouramputatedlimbs AT sanchetiparag doessubepineuralinjectiondamagethenerveintegrityatechnicalreportfromfouramputatedlimbs AT zundertandrevan doessubepineuralinjectiondamagethenerveintegrityatechnicalreportfromfouramputatedlimbs |