Cargando…

Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs

Local anesthetic (LA) injection outside the sheath in epineural or paraneural connective tissue is considered safe practice among regional anesthesiologists. There is limited evidence as to whether neurological complications occur if LA is injected inside the sheath (subepineural - intraneural). We...

Descripción completa

Detalles Bibliográficos
Autores principales: Diwan, Sandeep, Nair, Abhijit, Sancheti, Parag, Zundert, André Van
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Pain Society 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7783848/
https://www.ncbi.nlm.nih.gov/pubmed/33380576
http://dx.doi.org/10.3344/kjp.2021.34.1.132
_version_ 1783632184026857472
author Diwan, Sandeep
Nair, Abhijit
Sancheti, Parag
Zundert, André Van
author_facet Diwan, Sandeep
Nair, Abhijit
Sancheti, Parag
Zundert, André Van
author_sort Diwan, Sandeep
collection PubMed
description Local anesthetic (LA) injection outside the sheath in epineural or paraneural connective tissue is considered safe practice among regional anesthesiologists. There is limited evidence as to whether neurological complications occur if LA is injected inside the sheath (subepineural - intraneural). We performed ultrasound guided injections at the level of undivided sciatic nerve in four amputated lower limbs. In two specimens, LA was injected in epineural connective tissue (paraneural tissue) and in another two specimens by penetrating the outer nerve sheath (hyperechoic epineurium). Ultrasonography demonstrated an increase in the size of nerve and macroscopic findings revealed fascicular tracings with sub-epineural injections. Limbs were sent for histological analysis in formalin containers. Pathologist performed the analysis which demonstrated an intact perineurium and a breach in the epineurium. We conclude that sub-epineural injections are unsafe and injection should be done in paraneural tissue to ensure safety and avoid unwanted neurological sequelae after the block.
format Online
Article
Text
id pubmed-7783848
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Korean Pain Society
record_format MEDLINE/PubMed
spelling pubmed-77838482021-01-11 Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs Diwan, Sandeep Nair, Abhijit Sancheti, Parag Zundert, André Van Korean J Pain Case Report Local anesthetic (LA) injection outside the sheath in epineural or paraneural connective tissue is considered safe practice among regional anesthesiologists. There is limited evidence as to whether neurological complications occur if LA is injected inside the sheath (subepineural - intraneural). We performed ultrasound guided injections at the level of undivided sciatic nerve in four amputated lower limbs. In two specimens, LA was injected in epineural connective tissue (paraneural tissue) and in another two specimens by penetrating the outer nerve sheath (hyperechoic epineurium). Ultrasonography demonstrated an increase in the size of nerve and macroscopic findings revealed fascicular tracings with sub-epineural injections. Limbs were sent for histological analysis in formalin containers. Pathologist performed the analysis which demonstrated an intact perineurium and a breach in the epineurium. We conclude that sub-epineural injections are unsafe and injection should be done in paraneural tissue to ensure safety and avoid unwanted neurological sequelae after the block. The Korean Pain Society 2021-01-01 2021-01-01 /pmc/articles/PMC7783848/ /pubmed/33380576 http://dx.doi.org/10.3344/kjp.2021.34.1.132 Text en © The Korean Pain Society, 2021 This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Diwan, Sandeep
Nair, Abhijit
Sancheti, Parag
Zundert, André Van
Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs
title Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs
title_full Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs
title_fullStr Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs
title_full_unstemmed Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs
title_short Does subepineural injection damage the nerve integrity? A technical report from four amputated limbs
title_sort does subepineural injection damage the nerve integrity? a technical report from four amputated limbs
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7783848/
https://www.ncbi.nlm.nih.gov/pubmed/33380576
http://dx.doi.org/10.3344/kjp.2021.34.1.132
work_keys_str_mv AT diwansandeep doessubepineuralinjectiondamagethenerveintegrityatechnicalreportfromfouramputatedlimbs
AT nairabhijit doessubepineuralinjectiondamagethenerveintegrityatechnicalreportfromfouramputatedlimbs
AT sanchetiparag doessubepineuralinjectiondamagethenerveintegrityatechnicalreportfromfouramputatedlimbs
AT zundertandrevan doessubepineuralinjectiondamagethenerveintegrityatechnicalreportfromfouramputatedlimbs