Cargando…
A review on chest CT scanning parameters implemented in COVID-19 patients: bringing low-dose CT protocols into play
BACKGROUND: This study aims to review chest computed tomography (CT) scanning parameters which are utilized to evaluate patients for COVID-19-induced pneumonia. Also, some of radiation dose reduction techniques in CT would be mentioned, because using these techniques or low-dose protocol can decreas...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7784224/ http://dx.doi.org/10.1186/s43055-020-00400-1 |
_version_ | 1783632265489678336 |
---|---|
author | Azadbakht, Javid Khoramian, Daryoush Lajevardi, Zahra Sadat Elikaii, Fateme Aflatoonian, Amir Hossein Farhood, Bagher Najafi, Masoud Bagheri, Hamed |
author_facet | Azadbakht, Javid Khoramian, Daryoush Lajevardi, Zahra Sadat Elikaii, Fateme Aflatoonian, Amir Hossein Farhood, Bagher Najafi, Masoud Bagheri, Hamed |
author_sort | Azadbakht, Javid |
collection | PubMed |
description | BACKGROUND: This study aims to review chest computed tomography (CT) scanning parameters which are utilized to evaluate patients for COVID-19-induced pneumonia. Also, some of radiation dose reduction techniques in CT would be mentioned, because using these techniques or low-dose protocol can decrease the radiation burden on the population. MAIN BODY: Chest CT scan can play a key diagnostic role in COVID-19 patients. Additionally, it can be useful to monitor imaging changes during treatment. However, CT scan overuse during the COVID-19 pandemic raises concerns about radiation-induced adverse effects, both in patients and healthcare workers. CONCLUSION: By evaluating the CT scanning parameters used in several studies, one can find the necessity for optimizing these parameters. It has been found that chest CT scan taken using low-dose CT protocol is a reliable diagnostic tool to detect COVID-19 pneumonia in daily practice. Moreover, the low-dose chest CT protocol results in a remarkable reduction (up to 89%) in the radiation dose compared to the standard-dose protocol, not lowering diagnostic accuracy of COVID-19-induced pneumonia in CT images. Therefore, its employment in the era of the COVID-19 pandemic is highly recommended. |
format | Online Article Text |
id | pubmed-7784224 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-77842242021-01-05 A review on chest CT scanning parameters implemented in COVID-19 patients: bringing low-dose CT protocols into play Azadbakht, Javid Khoramian, Daryoush Lajevardi, Zahra Sadat Elikaii, Fateme Aflatoonian, Amir Hossein Farhood, Bagher Najafi, Masoud Bagheri, Hamed Egypt J Radiol Nucl Med Review BACKGROUND: This study aims to review chest computed tomography (CT) scanning parameters which are utilized to evaluate patients for COVID-19-induced pneumonia. Also, some of radiation dose reduction techniques in CT would be mentioned, because using these techniques or low-dose protocol can decrease the radiation burden on the population. MAIN BODY: Chest CT scan can play a key diagnostic role in COVID-19 patients. Additionally, it can be useful to monitor imaging changes during treatment. However, CT scan overuse during the COVID-19 pandemic raises concerns about radiation-induced adverse effects, both in patients and healthcare workers. CONCLUSION: By evaluating the CT scanning parameters used in several studies, one can find the necessity for optimizing these parameters. It has been found that chest CT scan taken using low-dose CT protocol is a reliable diagnostic tool to detect COVID-19 pneumonia in daily practice. Moreover, the low-dose chest CT protocol results in a remarkable reduction (up to 89%) in the radiation dose compared to the standard-dose protocol, not lowering diagnostic accuracy of COVID-19-induced pneumonia in CT images. Therefore, its employment in the era of the COVID-19 pandemic is highly recommended. Springer Berlin Heidelberg 2021-01-05 2021 /pmc/articles/PMC7784224/ http://dx.doi.org/10.1186/s43055-020-00400-1 Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Review Azadbakht, Javid Khoramian, Daryoush Lajevardi, Zahra Sadat Elikaii, Fateme Aflatoonian, Amir Hossein Farhood, Bagher Najafi, Masoud Bagheri, Hamed A review on chest CT scanning parameters implemented in COVID-19 patients: bringing low-dose CT protocols into play |
title | A review on chest CT scanning parameters implemented in COVID-19 patients: bringing low-dose CT protocols into play |
title_full | A review on chest CT scanning parameters implemented in COVID-19 patients: bringing low-dose CT protocols into play |
title_fullStr | A review on chest CT scanning parameters implemented in COVID-19 patients: bringing low-dose CT protocols into play |
title_full_unstemmed | A review on chest CT scanning parameters implemented in COVID-19 patients: bringing low-dose CT protocols into play |
title_short | A review on chest CT scanning parameters implemented in COVID-19 patients: bringing low-dose CT protocols into play |
title_sort | review on chest ct scanning parameters implemented in covid-19 patients: bringing low-dose ct protocols into play |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7784224/ http://dx.doi.org/10.1186/s43055-020-00400-1 |
work_keys_str_mv | AT azadbakhtjavid areviewonchestctscanningparametersimplementedincovid19patientsbringinglowdosectprotocolsintoplay AT khoramiandaryoush areviewonchestctscanningparametersimplementedincovid19patientsbringinglowdosectprotocolsintoplay AT lajevardizahrasadat areviewonchestctscanningparametersimplementedincovid19patientsbringinglowdosectprotocolsintoplay AT elikaiifateme areviewonchestctscanningparametersimplementedincovid19patientsbringinglowdosectprotocolsintoplay AT aflatoonianamirhossein areviewonchestctscanningparametersimplementedincovid19patientsbringinglowdosectprotocolsintoplay AT farhoodbagher areviewonchestctscanningparametersimplementedincovid19patientsbringinglowdosectprotocolsintoplay AT najafimasoud areviewonchestctscanningparametersimplementedincovid19patientsbringinglowdosectprotocolsintoplay AT bagherihamed areviewonchestctscanningparametersimplementedincovid19patientsbringinglowdosectprotocolsintoplay AT azadbakhtjavid reviewonchestctscanningparametersimplementedincovid19patientsbringinglowdosectprotocolsintoplay AT khoramiandaryoush reviewonchestctscanningparametersimplementedincovid19patientsbringinglowdosectprotocolsintoplay AT lajevardizahrasadat reviewonchestctscanningparametersimplementedincovid19patientsbringinglowdosectprotocolsintoplay AT elikaiifateme reviewonchestctscanningparametersimplementedincovid19patientsbringinglowdosectprotocolsintoplay AT aflatoonianamirhossein reviewonchestctscanningparametersimplementedincovid19patientsbringinglowdosectprotocolsintoplay AT farhoodbagher reviewonchestctscanningparametersimplementedincovid19patientsbringinglowdosectprotocolsintoplay AT najafimasoud reviewonchestctscanningparametersimplementedincovid19patientsbringinglowdosectprotocolsintoplay AT bagherihamed reviewonchestctscanningparametersimplementedincovid19patientsbringinglowdosectprotocolsintoplay |