Cargando…
Feasibility and Reliability of Two-Dimensional Shear-Wave Elastography of the Liver of Clinically Healthy Cats
Given the broad overlap of normal and abnormal liver tissue in the subjective evaluation of the liver in conventional B-mode ultrasonography, there is a need for a non-invasive and quantitative method for the diagnosis of liver disease. Novel two-dimensional shear-wave elastography (2-D SWE) can mea...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7785986/ https://www.ncbi.nlm.nih.gov/pubmed/33426033 http://dx.doi.org/10.3389/fvets.2020.614750 |
_version_ | 1783632537885605888 |
---|---|
author | Kim, Kyeonga Lee, Jieun So, Jaebeom Jang, Yong-seok Jung, Mingyu Kang, Kyuyong Choi, Mincheol Yoon, Junghee |
author_facet | Kim, Kyeonga Lee, Jieun So, Jaebeom Jang, Yong-seok Jung, Mingyu Kang, Kyuyong Choi, Mincheol Yoon, Junghee |
author_sort | Kim, Kyeonga |
collection | PubMed |
description | Given the broad overlap of normal and abnormal liver tissue in the subjective evaluation of the liver in conventional B-mode ultrasonography, there is a need for a non-invasive and quantitative method for the diagnosis of liver disease. Novel two-dimensional shear-wave elastography (2-D SWE) can measure tissue stiffness by propagation of the shear wave induced using acoustic radiation force impulse in real time. To the best of our knowledge, two-dimensional shear-wave measurement of the liver in cats has not been reported to date. This study assessed the feasibility, reliability, normal values, and related influencing factors of 2-D SWE for assessment of the feline liver without anesthesia and breath-holding. Two-dimensional shear-wave ultrasonography was performed by two evaluators at the right and left sides of the liver. Twenty-nine client-owned clinically healthy adult cats were included. The means and standard deviations for the shear-wave speed and stiffness in the right liver were 1.52 ± 0.13 m/s and 6.94 ± 1.26 kPa, respectively, and those for the left liver were 1.61 ± 0.15 m/s and 7.90 ± 1.47 kPa, respectively. Shear-wave speed (P = 0.005) and stiffness (P = 0.002) were significantly lower in the right liver when compared to the left. The intraclass correlation value for liver stiffness was 0.835 and 0.901 for the right and left liver, respectively, indicating high interobserver agreement. Age, weight, body condition score (BCS), gabapentin administration, and measurement depths were not significantly correlated with liver stiffness or elastography measurements (P > 0.05). Our findings suggest that 2-D SWE measurements of the liver are not influenced significantly by age, weight, or BCS and can be reliably performed without anesthesia and breath-holding in cats. The values determined here can help form the basis for reference elastography values for evaluation of the feline liver. |
format | Online Article Text |
id | pubmed-7785986 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-77859862021-01-07 Feasibility and Reliability of Two-Dimensional Shear-Wave Elastography of the Liver of Clinically Healthy Cats Kim, Kyeonga Lee, Jieun So, Jaebeom Jang, Yong-seok Jung, Mingyu Kang, Kyuyong Choi, Mincheol Yoon, Junghee Front Vet Sci Veterinary Science Given the broad overlap of normal and abnormal liver tissue in the subjective evaluation of the liver in conventional B-mode ultrasonography, there is a need for a non-invasive and quantitative method for the diagnosis of liver disease. Novel two-dimensional shear-wave elastography (2-D SWE) can measure tissue stiffness by propagation of the shear wave induced using acoustic radiation force impulse in real time. To the best of our knowledge, two-dimensional shear-wave measurement of the liver in cats has not been reported to date. This study assessed the feasibility, reliability, normal values, and related influencing factors of 2-D SWE for assessment of the feline liver without anesthesia and breath-holding. Two-dimensional shear-wave ultrasonography was performed by two evaluators at the right and left sides of the liver. Twenty-nine client-owned clinically healthy adult cats were included. The means and standard deviations for the shear-wave speed and stiffness in the right liver were 1.52 ± 0.13 m/s and 6.94 ± 1.26 kPa, respectively, and those for the left liver were 1.61 ± 0.15 m/s and 7.90 ± 1.47 kPa, respectively. Shear-wave speed (P = 0.005) and stiffness (P = 0.002) were significantly lower in the right liver when compared to the left. The intraclass correlation value for liver stiffness was 0.835 and 0.901 for the right and left liver, respectively, indicating high interobserver agreement. Age, weight, body condition score (BCS), gabapentin administration, and measurement depths were not significantly correlated with liver stiffness or elastography measurements (P > 0.05). Our findings suggest that 2-D SWE measurements of the liver are not influenced significantly by age, weight, or BCS and can be reliably performed without anesthesia and breath-holding in cats. The values determined here can help form the basis for reference elastography values for evaluation of the feline liver. Frontiers Media S.A. 2020-12-23 /pmc/articles/PMC7785986/ /pubmed/33426033 http://dx.doi.org/10.3389/fvets.2020.614750 Text en Copyright © 2020 Kim, Lee, So, Jang, Jung, Kang, Choi and Yoon. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Veterinary Science Kim, Kyeonga Lee, Jieun So, Jaebeom Jang, Yong-seok Jung, Mingyu Kang, Kyuyong Choi, Mincheol Yoon, Junghee Feasibility and Reliability of Two-Dimensional Shear-Wave Elastography of the Liver of Clinically Healthy Cats |
title | Feasibility and Reliability of Two-Dimensional Shear-Wave Elastography of the Liver of Clinically Healthy Cats |
title_full | Feasibility and Reliability of Two-Dimensional Shear-Wave Elastography of the Liver of Clinically Healthy Cats |
title_fullStr | Feasibility and Reliability of Two-Dimensional Shear-Wave Elastography of the Liver of Clinically Healthy Cats |
title_full_unstemmed | Feasibility and Reliability of Two-Dimensional Shear-Wave Elastography of the Liver of Clinically Healthy Cats |
title_short | Feasibility and Reliability of Two-Dimensional Shear-Wave Elastography of the Liver of Clinically Healthy Cats |
title_sort | feasibility and reliability of two-dimensional shear-wave elastography of the liver of clinically healthy cats |
topic | Veterinary Science |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7785986/ https://www.ncbi.nlm.nih.gov/pubmed/33426033 http://dx.doi.org/10.3389/fvets.2020.614750 |
work_keys_str_mv | AT kimkyeonga feasibilityandreliabilityoftwodimensionalshearwaveelastographyoftheliverofclinicallyhealthycats AT leejieun feasibilityandreliabilityoftwodimensionalshearwaveelastographyoftheliverofclinicallyhealthycats AT sojaebeom feasibilityandreliabilityoftwodimensionalshearwaveelastographyoftheliverofclinicallyhealthycats AT jangyongseok feasibilityandreliabilityoftwodimensionalshearwaveelastographyoftheliverofclinicallyhealthycats AT jungmingyu feasibilityandreliabilityoftwodimensionalshearwaveelastographyoftheliverofclinicallyhealthycats AT kangkyuyong feasibilityandreliabilityoftwodimensionalshearwaveelastographyoftheliverofclinicallyhealthycats AT choimincheol feasibilityandreliabilityoftwodimensionalshearwaveelastographyoftheliverofclinicallyhealthycats AT yoonjunghee feasibilityandreliabilityoftwodimensionalshearwaveelastographyoftheliverofclinicallyhealthycats |