Cargando…

Modular tapered conical revision stem in hip revision surgery: mid- term results

BACKGROUND: The aim of this paper is to evaluate the clinical and radiological outcomes of a fluted tapered modular distal-fixation stem at medium to long-term follow-up. The hypothesis of this investigation was to verify if the use of this implant design may have provided potential advantages in fe...

Descripción completa

Detalles Bibliográficos
Autores principales: Perticarini, Loris, Rossi, Stefano Marco Paolo, Fioruzzi, Alberto, Jannelli, Eugenio, Mosconi, Mario, Benazzo, Francesco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7786466/
https://www.ncbi.nlm.nih.gov/pubmed/33407327
http://dx.doi.org/10.1186/s12891-020-03886-y
_version_ 1783632630908977152
author Perticarini, Loris
Rossi, Stefano Marco Paolo
Fioruzzi, Alberto
Jannelli, Eugenio
Mosconi, Mario
Benazzo, Francesco
author_facet Perticarini, Loris
Rossi, Stefano Marco Paolo
Fioruzzi, Alberto
Jannelli, Eugenio
Mosconi, Mario
Benazzo, Francesco
author_sort Perticarini, Loris
collection PubMed
description BACKGROUND: The aim of this paper is to evaluate the clinical and radiological outcomes of a fluted tapered modular distal-fixation stem at medium to long-term follow-up. The hypothesis of this investigation was to verify if the use of this implant design may have provided potential advantages in femoral revisions and post-traumatic instances where the restoration of the anatomy was the prime concern. METHODS: We retrospectively reviewed 62 cases of femoral revision surgeries, performed in Paprosky type IIIA and IIIB bone defects between January 2001 and December 2011 with a mean follow-up of 8.5 ± 1.5 years (range 5.1–15.9 years) where a modular fluted stem was used. The clinical assessment was performed with the Harris Hip Score (HHS), and the radiographic evaluation was carried in order to assess the stability of the femoral component. Intra-operative and postoperative complications were recorded, and the rates of complications and revisions for any cause were determined. RESULTS: Mean HHS improved 35.4 points from the preoperative assessment. Radiographic evaluation showed a stable stem anchorage in 90.3% of the cases at the last follow-up. Five (8%) implants required additional surgery. Neither breakage of the stem nor loosening of the taper junction were recorded. Kaplan-Meier survivorship was 89.4% (CI: 88.8–90%) for any complication and 92.3% (CI: 91.8–92.7%) according to revision for any causes at 81 months follow-up. CONCLUSIONS: Our findings suggest that this stem design is a reliable option in cases of complex femoral bone defects, as well as in cases with high functional deficiencies, with promising survivorship.
format Online
Article
Text
id pubmed-7786466
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-77864662021-01-07 Modular tapered conical revision stem in hip revision surgery: mid- term results Perticarini, Loris Rossi, Stefano Marco Paolo Fioruzzi, Alberto Jannelli, Eugenio Mosconi, Mario Benazzo, Francesco BMC Musculoskelet Disord Research Article BACKGROUND: The aim of this paper is to evaluate the clinical and radiological outcomes of a fluted tapered modular distal-fixation stem at medium to long-term follow-up. The hypothesis of this investigation was to verify if the use of this implant design may have provided potential advantages in femoral revisions and post-traumatic instances where the restoration of the anatomy was the prime concern. METHODS: We retrospectively reviewed 62 cases of femoral revision surgeries, performed in Paprosky type IIIA and IIIB bone defects between January 2001 and December 2011 with a mean follow-up of 8.5 ± 1.5 years (range 5.1–15.9 years) where a modular fluted stem was used. The clinical assessment was performed with the Harris Hip Score (HHS), and the radiographic evaluation was carried in order to assess the stability of the femoral component. Intra-operative and postoperative complications were recorded, and the rates of complications and revisions for any cause were determined. RESULTS: Mean HHS improved 35.4 points from the preoperative assessment. Radiographic evaluation showed a stable stem anchorage in 90.3% of the cases at the last follow-up. Five (8%) implants required additional surgery. Neither breakage of the stem nor loosening of the taper junction were recorded. Kaplan-Meier survivorship was 89.4% (CI: 88.8–90%) for any complication and 92.3% (CI: 91.8–92.7%) according to revision for any causes at 81 months follow-up. CONCLUSIONS: Our findings suggest that this stem design is a reliable option in cases of complex femoral bone defects, as well as in cases with high functional deficiencies, with promising survivorship. BioMed Central 2021-01-06 /pmc/articles/PMC7786466/ /pubmed/33407327 http://dx.doi.org/10.1186/s12891-020-03886-y Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Perticarini, Loris
Rossi, Stefano Marco Paolo
Fioruzzi, Alberto
Jannelli, Eugenio
Mosconi, Mario
Benazzo, Francesco
Modular tapered conical revision stem in hip revision surgery: mid- term results
title Modular tapered conical revision stem in hip revision surgery: mid- term results
title_full Modular tapered conical revision stem in hip revision surgery: mid- term results
title_fullStr Modular tapered conical revision stem in hip revision surgery: mid- term results
title_full_unstemmed Modular tapered conical revision stem in hip revision surgery: mid- term results
title_short Modular tapered conical revision stem in hip revision surgery: mid- term results
title_sort modular tapered conical revision stem in hip revision surgery: mid- term results
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7786466/
https://www.ncbi.nlm.nih.gov/pubmed/33407327
http://dx.doi.org/10.1186/s12891-020-03886-y
work_keys_str_mv AT perticariniloris modulartaperedconicalrevisionsteminhiprevisionsurgerymidtermresults
AT rossistefanomarcopaolo modulartaperedconicalrevisionsteminhiprevisionsurgerymidtermresults
AT fioruzzialberto modulartaperedconicalrevisionsteminhiprevisionsurgerymidtermresults
AT jannellieugenio modulartaperedconicalrevisionsteminhiprevisionsurgerymidtermresults
AT mosconimario modulartaperedconicalrevisionsteminhiprevisionsurgerymidtermresults
AT benazzofrancesco modulartaperedconicalrevisionsteminhiprevisionsurgerymidtermresults