Accuracy of Patient-Specific 3D-Printed Drill Guides for Pedicle and Lateral Mass Screw Insertion: An Analysis of 76 Cervical and Thoracic Screw Trajectories

STUDY DESIGN. Single-center retrospective case series. OBJECTIVE. The purpose of this study was to assess the safety and accuracy of three-dimensional (3D)-printed individualized drill guides for pedicle and lateral mass screw insertion in the cervical and upper-thoracic region, by comparing the pre...

Descripción completa

Detalles Bibliográficos
Autores principales: Pijpker, Peter A.J., Kraeima, Joep, Witjes, Max J.H., Oterdoom, D.L. Marinus, Vergeer, Rob A., Coppes, Maarten H., Groen, Rob J.M., Kuijlen, Jos M.A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7787187/
https://www.ncbi.nlm.nih.gov/pubmed/33093310
http://dx.doi.org/10.1097/BRS.0000000000003747
_version_ 1783632776819376128
author Pijpker, Peter A.J.
Kraeima, Joep
Witjes, Max J.H.
Oterdoom, D.L. Marinus
Vergeer, Rob A.
Coppes, Maarten H.
Groen, Rob J.M.
Kuijlen, Jos M.A.
author_facet Pijpker, Peter A.J.
Kraeima, Joep
Witjes, Max J.H.
Oterdoom, D.L. Marinus
Vergeer, Rob A.
Coppes, Maarten H.
Groen, Rob J.M.
Kuijlen, Jos M.A.
author_sort Pijpker, Peter A.J.
collection PubMed
description STUDY DESIGN. Single-center retrospective case series. OBJECTIVE. The purpose of this study was to assess the safety and accuracy of three-dimensional (3D)-printed individualized drill guides for pedicle and lateral mass screw insertion in the cervical and upper-thoracic region, by comparing the preoperative 3D surgical plan with the postoperative results. SUMMARY OF BACKGROUND DATA. Posterior spinal fusion surgery can provide rigid intervertebral fixation but screw misplacement involves a high risk of neurovascular injury. However, modern spine surgeons now have tools such as virtual surgical planning and 3D-printed drill guides to facilitate spinal screw insertion. METHODS. A total of 15 patients who underwent posterior spinal fusion surgery involving patient-specific 3D-printed drill guides were included in this study. After segmentation of bone and screws, the postoperative models were superimposed onto the preoperative surgical plan. The accuracy of the realized screw trajectories was quantified by measuring the entry point and angular deviation. RESULTS. The 3D deviation analysis showed that the entry point and angular deviation over all 76 screw trajectories were 1.40 ± 0.81 mm and 6.70 ± 3.77°, respectively. Angular deviation was significantly higher in the sagittal plane than in the axial plane (P = 0.02). All screw positions were classified as “safe” (100%), showing no neurovascular injury, facet joint violation, or violation of the pedicle wall. CONCLUSIONS. 3D virtual planning and 3D-printed patient-specific drill guides appear to be safe and accurate for pedicle and lateral mass screw insertion in the cervical and upper-thoracic spine. The quantitative 3D deviation analyses confirmed that screw positions were accurate with respect to the 3D-surgical plan. Level of Evidence: 4
format Online
Article
Text
id pubmed-7787187
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-77871872021-01-06 Accuracy of Patient-Specific 3D-Printed Drill Guides for Pedicle and Lateral Mass Screw Insertion: An Analysis of 76 Cervical and Thoracic Screw Trajectories Pijpker, Peter A.J. Kraeima, Joep Witjes, Max J.H. Oterdoom, D.L. Marinus Vergeer, Rob A. Coppes, Maarten H. Groen, Rob J.M. Kuijlen, Jos M.A. Spine (Phila Pa 1976) Clinical Case Series STUDY DESIGN. Single-center retrospective case series. OBJECTIVE. The purpose of this study was to assess the safety and accuracy of three-dimensional (3D)-printed individualized drill guides for pedicle and lateral mass screw insertion in the cervical and upper-thoracic region, by comparing the preoperative 3D surgical plan with the postoperative results. SUMMARY OF BACKGROUND DATA. Posterior spinal fusion surgery can provide rigid intervertebral fixation but screw misplacement involves a high risk of neurovascular injury. However, modern spine surgeons now have tools such as virtual surgical planning and 3D-printed drill guides to facilitate spinal screw insertion. METHODS. A total of 15 patients who underwent posterior spinal fusion surgery involving patient-specific 3D-printed drill guides were included in this study. After segmentation of bone and screws, the postoperative models were superimposed onto the preoperative surgical plan. The accuracy of the realized screw trajectories was quantified by measuring the entry point and angular deviation. RESULTS. The 3D deviation analysis showed that the entry point and angular deviation over all 76 screw trajectories were 1.40 ± 0.81 mm and 6.70 ± 3.77°, respectively. Angular deviation was significantly higher in the sagittal plane than in the axial plane (P = 0.02). All screw positions were classified as “safe” (100%), showing no neurovascular injury, facet joint violation, or violation of the pedicle wall. CONCLUSIONS. 3D virtual planning and 3D-printed patient-specific drill guides appear to be safe and accurate for pedicle and lateral mass screw insertion in the cervical and upper-thoracic spine. The quantitative 3D deviation analyses confirmed that screw positions were accurate with respect to the 3D-surgical plan. Level of Evidence: 4 Lippincott Williams & Wilkins 2021-02-01 2020-10-21 /pmc/articles/PMC7787187/ /pubmed/33093310 http://dx.doi.org/10.1097/BRS.0000000000003747 Text en Copyright © 2020 The Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle Clinical Case Series
Pijpker, Peter A.J.
Kraeima, Joep
Witjes, Max J.H.
Oterdoom, D.L. Marinus
Vergeer, Rob A.
Coppes, Maarten H.
Groen, Rob J.M.
Kuijlen, Jos M.A.
Accuracy of Patient-Specific 3D-Printed Drill Guides for Pedicle and Lateral Mass Screw Insertion: An Analysis of 76 Cervical and Thoracic Screw Trajectories
title Accuracy of Patient-Specific 3D-Printed Drill Guides for Pedicle and Lateral Mass Screw Insertion: An Analysis of 76 Cervical and Thoracic Screw Trajectories
title_full Accuracy of Patient-Specific 3D-Printed Drill Guides for Pedicle and Lateral Mass Screw Insertion: An Analysis of 76 Cervical and Thoracic Screw Trajectories
title_fullStr Accuracy of Patient-Specific 3D-Printed Drill Guides for Pedicle and Lateral Mass Screw Insertion: An Analysis of 76 Cervical and Thoracic Screw Trajectories
title_full_unstemmed Accuracy of Patient-Specific 3D-Printed Drill Guides for Pedicle and Lateral Mass Screw Insertion: An Analysis of 76 Cervical and Thoracic Screw Trajectories
title_short Accuracy of Patient-Specific 3D-Printed Drill Guides for Pedicle and Lateral Mass Screw Insertion: An Analysis of 76 Cervical and Thoracic Screw Trajectories
title_sort accuracy of patient-specific 3d-printed drill guides for pedicle and lateral mass screw insertion: an analysis of 76 cervical and thoracic screw trajectories
topic Clinical Case Series
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7787187/
https://www.ncbi.nlm.nih.gov/pubmed/33093310
http://dx.doi.org/10.1097/BRS.0000000000003747
work_keys_str_mv AT pijpkerpeteraj accuracyofpatientspecific3dprinteddrillguidesforpedicleandlateralmassscrewinsertionananalysisof76cervicalandthoracicscrewtrajectories
AT kraeimajoep accuracyofpatientspecific3dprinteddrillguidesforpedicleandlateralmassscrewinsertionananalysisof76cervicalandthoracicscrewtrajectories
AT witjesmaxjh accuracyofpatientspecific3dprinteddrillguidesforpedicleandlateralmassscrewinsertionananalysisof76cervicalandthoracicscrewtrajectories
AT oterdoomdlmarinus accuracyofpatientspecific3dprinteddrillguidesforpedicleandlateralmassscrewinsertionananalysisof76cervicalandthoracicscrewtrajectories
AT vergeerroba accuracyofpatientspecific3dprinteddrillguidesforpedicleandlateralmassscrewinsertionananalysisof76cervicalandthoracicscrewtrajectories
AT coppesmaartenh accuracyofpatientspecific3dprinteddrillguidesforpedicleandlateralmassscrewinsertionananalysisof76cervicalandthoracicscrewtrajectories
AT groenrobjm accuracyofpatientspecific3dprinteddrillguidesforpedicleandlateralmassscrewinsertionananalysisof76cervicalandthoracicscrewtrajectories
AT kuijlenjosma accuracyofpatientspecific3dprinteddrillguidesforpedicleandlateralmassscrewinsertionananalysisof76cervicalandthoracicscrewtrajectories