Intra- and Inter-Rater Reliability of Ultrasound Measurements of Supraspinatus Tendon Thickness, Acromiohumeral Distance, and Occupation Ratio in Patients With Shoulder Impingement Syndrome

OBJECTIVES: This study aims to evaluate the intra- and inter-rater reliability coefficients of the supraspinatus tendon thickness, acromiohumeral distance, and occupation ratio in patients with shoulder impingement syndrome. PATIENTS AND METHODS: The study included 83 patients (21 males, 62 females;...

Descripción completa

Detalles Bibliográficos
Autores principales: BAĞCIER, Fatih, GELER KÜLCÜ, Duygu, YORULMAZ, Elem, ALTUNOK, Elif Çiğdem
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Turkish League Against Rheumatism 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7788650/
https://www.ncbi.nlm.nih.gov/pubmed/33458662
http://dx.doi.org/10.46497/ArchRheumatol.2020.7515
_version_ 1783633072880615424
author BAĞCIER, Fatih
GELER KÜLCÜ, Duygu
YORULMAZ, Elem
ALTUNOK, Elif Çiğdem
author_facet BAĞCIER, Fatih
GELER KÜLCÜ, Duygu
YORULMAZ, Elem
ALTUNOK, Elif Çiğdem
author_sort BAĞCIER, Fatih
collection PubMed
description OBJECTIVES: This study aims to evaluate the intra- and inter-rater reliability coefficients of the supraspinatus tendon thickness, acromiohumeral distance, and occupation ratio in patients with shoulder impingement syndrome. PATIENTS AND METHODS: The study included 83 patients (21 males, 62 females; mean age 51.6±11.0 years; range, 26 to 70 years) with shoulder impingement syndrome. The supraspinatus tendon thickness, acromiohumeral distance, and occupation ratio values were obtained one week apart by two observers. The intraclass correlation coefficient (ICC), minimum detectable change, and standard error of measurement were calculated. RESULTS: The first observer had excellent intra-rater reliability in all measurements (ICC >0.90) with minimum detectable change of 0.740-0.047 mm and standard error of measurement of 0.017-0.26 mm. The second observer had excellent intra-rater reliability in supraspinatus tendon thickness and acromiohumeral distance measurements (ICC >0.90) with minimum detectable change of 0.498-0.770 mm and standard error of measurement of 0.18-0.28 mm and good intra-rater reliability in the occupation ratio measurement (ICC; 0.75-0.90) with minimum detectable change of 0.060 mm and standard error of measurement of 0.022 mm. Inter-rater reliability coefficients were 0.916 (95% confidence interval [CI]; 0.873-0.945) for supraspinatus tendon thickness, 0.943 (95% CI; 0.914-0.963) for acromiohumeral distance with minimum detectable change of 0.673 mm and standard error of measurement of 0.243 mm and 0.790 (%95 CI; 0.693-0.853) for occupation ratio with minimum detectable change of 0.077 mm and standard error of measurement of 0.028 mm. CONCLUSION: These findings suggest that ultrasonographic measurements of the supraspinatus tendon thickness, acromiohumeral distance and occupation ratio can be reliable and consistent for clinical evaluation of patients with shoulder impingement syndrome in terms of supporting diagnosis and monitoring the treatment effect.
format Online
Article
Text
id pubmed-7788650
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Turkish League Against Rheumatism
record_format MEDLINE/PubMed
spelling pubmed-77886502021-01-14 Intra- and Inter-Rater Reliability of Ultrasound Measurements of Supraspinatus Tendon Thickness, Acromiohumeral Distance, and Occupation Ratio in Patients With Shoulder Impingement Syndrome BAĞCIER, Fatih GELER KÜLCÜ, Duygu YORULMAZ, Elem ALTUNOK, Elif Çiğdem Arch Rheumatol Original Article OBJECTIVES: This study aims to evaluate the intra- and inter-rater reliability coefficients of the supraspinatus tendon thickness, acromiohumeral distance, and occupation ratio in patients with shoulder impingement syndrome. PATIENTS AND METHODS: The study included 83 patients (21 males, 62 females; mean age 51.6±11.0 years; range, 26 to 70 years) with shoulder impingement syndrome. The supraspinatus tendon thickness, acromiohumeral distance, and occupation ratio values were obtained one week apart by two observers. The intraclass correlation coefficient (ICC), minimum detectable change, and standard error of measurement were calculated. RESULTS: The first observer had excellent intra-rater reliability in all measurements (ICC >0.90) with minimum detectable change of 0.740-0.047 mm and standard error of measurement of 0.017-0.26 mm. The second observer had excellent intra-rater reliability in supraspinatus tendon thickness and acromiohumeral distance measurements (ICC >0.90) with minimum detectable change of 0.498-0.770 mm and standard error of measurement of 0.18-0.28 mm and good intra-rater reliability in the occupation ratio measurement (ICC; 0.75-0.90) with minimum detectable change of 0.060 mm and standard error of measurement of 0.022 mm. Inter-rater reliability coefficients were 0.916 (95% confidence interval [CI]; 0.873-0.945) for supraspinatus tendon thickness, 0.943 (95% CI; 0.914-0.963) for acromiohumeral distance with minimum detectable change of 0.673 mm and standard error of measurement of 0.243 mm and 0.790 (%95 CI; 0.693-0.853) for occupation ratio with minimum detectable change of 0.077 mm and standard error of measurement of 0.028 mm. CONCLUSION: These findings suggest that ultrasonographic measurements of the supraspinatus tendon thickness, acromiohumeral distance and occupation ratio can be reliable and consistent for clinical evaluation of patients with shoulder impingement syndrome in terms of supporting diagnosis and monitoring the treatment effect. Turkish League Against Rheumatism 2020-02-07 /pmc/articles/PMC7788650/ /pubmed/33458662 http://dx.doi.org/10.46497/ArchRheumatol.2020.7515 Text en Copyright © 2020, Turkish League Against Rheumatism http://creativecommons.org/licenses/by-nc/4.0/ This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Article
BAĞCIER, Fatih
GELER KÜLCÜ, Duygu
YORULMAZ, Elem
ALTUNOK, Elif Çiğdem
Intra- and Inter-Rater Reliability of Ultrasound Measurements of Supraspinatus Tendon Thickness, Acromiohumeral Distance, and Occupation Ratio in Patients With Shoulder Impingement Syndrome
title Intra- and Inter-Rater Reliability of Ultrasound Measurements of Supraspinatus Tendon Thickness, Acromiohumeral Distance, and Occupation Ratio in Patients With Shoulder Impingement Syndrome
title_full Intra- and Inter-Rater Reliability of Ultrasound Measurements of Supraspinatus Tendon Thickness, Acromiohumeral Distance, and Occupation Ratio in Patients With Shoulder Impingement Syndrome
title_fullStr Intra- and Inter-Rater Reliability of Ultrasound Measurements of Supraspinatus Tendon Thickness, Acromiohumeral Distance, and Occupation Ratio in Patients With Shoulder Impingement Syndrome
title_full_unstemmed Intra- and Inter-Rater Reliability of Ultrasound Measurements of Supraspinatus Tendon Thickness, Acromiohumeral Distance, and Occupation Ratio in Patients With Shoulder Impingement Syndrome
title_short Intra- and Inter-Rater Reliability of Ultrasound Measurements of Supraspinatus Tendon Thickness, Acromiohumeral Distance, and Occupation Ratio in Patients With Shoulder Impingement Syndrome
title_sort intra- and inter-rater reliability of ultrasound measurements of supraspinatus tendon thickness, acromiohumeral distance, and occupation ratio in patients with shoulder impingement syndrome
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7788650/
https://www.ncbi.nlm.nih.gov/pubmed/33458662
http://dx.doi.org/10.46497/ArchRheumatol.2020.7515
work_keys_str_mv AT bagcierfatih intraandinterraterreliabilityofultrasoundmeasurementsofsupraspinatustendonthicknessacromiohumeraldistanceandoccupationratioinpatientswithshoulderimpingementsyndrome
AT gelerkulcuduygu intraandinterraterreliabilityofultrasoundmeasurementsofsupraspinatustendonthicknessacromiohumeraldistanceandoccupationratioinpatientswithshoulderimpingementsyndrome
AT yorulmazelem intraandinterraterreliabilityofultrasoundmeasurementsofsupraspinatustendonthicknessacromiohumeraldistanceandoccupationratioinpatientswithshoulderimpingementsyndrome
AT altunokelifcigdem intraandinterraterreliabilityofultrasoundmeasurementsofsupraspinatustendonthicknessacromiohumeraldistanceandoccupationratioinpatientswithshoulderimpingementsyndrome