Cargando…
Titanium-interlayer mediated hydroxyapatite coating on polyetheretherketone: a prospective study in patients with single-level cervical degenerative disc disease
BACKGROUND: Currently, there are limited reports regarding investigation of the biological properties of polyetheretherketone (PEEK) coated with titanium (Ti) and hydroxyapatite (HA) in human. The objective of this study is to evaluate the in vivo response of the PEEK cages coated with Ti and HA ver...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7788895/ https://www.ncbi.nlm.nih.gov/pubmed/33407627 http://dx.doi.org/10.1186/s12967-020-02688-z |
_version_ | 1783633123769057280 |
---|---|
author | Zhu, Ce He, Miaomiao Mao, Lili Li, Tao Zhang, Li Liu, Limin Feng, Ganjun Song, Yueming |
author_facet | Zhu, Ce He, Miaomiao Mao, Lili Li, Tao Zhang, Li Liu, Limin Feng, Ganjun Song, Yueming |
author_sort | Zhu, Ce |
collection | PubMed |
description | BACKGROUND: Currently, there are limited reports regarding investigation of the biological properties of polyetheretherketone (PEEK) coated with titanium (Ti) and hydroxyapatite (HA) in human. The objective of this study is to evaluate the in vivo response of the PEEK cages coated with Ti and HA versus uncoated PEEK cages after anterior cervical discectomy and fusion (ACDF) in patients with single-level cervical degenerative disc disease (CDDD). METHODS: Twenty-four patients with PEEK cages coated with Ti and HA (PEEK/Ti/HA group) were matched one-to-one with patients with uncoated PEEK cages (PEEK group) based on age, gender, and operative segment. All patients had been followed up for more than 2 years. Radiological assessments included intervertebral height (IH), C2-7 angle (C2-7a), segmental alignment (SA), and fusion rate. Clinical parameters included Visual Analogue Scale (VAS) and Japanese Orthopedic Association (JOA) scores. RESULTS: There was no statistical difference in SA, IH, and C2-7a between the two groups before and after surgery and all these parameters were restored postoperatively. The fusion rate of PEEK/Ti/HA group was significantly higher than PEEK group at 3-month post-operation (87.5% vs. 62.5%). At the last follow-up, the fusion rate of the both groups achieved 100%. The VAS and JOA scores were comparable between two groups and improved postoperatively. CONCLUSIONS: In patients with single-level ACDF, PEEK cage coated with Ti and HA provided a higher fusion rate than uncoated PEEK cage at 3-month post-operation, while both two cages could achieve solid osseous fusion at the last follow up. Compared with the uncoated PEEK cage, PEEK/Ti/HA cage yielded similar favorable segmental and overall cervical lordosis, IH, and clinical outcomes after the surgery. |
format | Online Article Text |
id | pubmed-7788895 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-77888952021-01-07 Titanium-interlayer mediated hydroxyapatite coating on polyetheretherketone: a prospective study in patients with single-level cervical degenerative disc disease Zhu, Ce He, Miaomiao Mao, Lili Li, Tao Zhang, Li Liu, Limin Feng, Ganjun Song, Yueming J Transl Med Research BACKGROUND: Currently, there are limited reports regarding investigation of the biological properties of polyetheretherketone (PEEK) coated with titanium (Ti) and hydroxyapatite (HA) in human. The objective of this study is to evaluate the in vivo response of the PEEK cages coated with Ti and HA versus uncoated PEEK cages after anterior cervical discectomy and fusion (ACDF) in patients with single-level cervical degenerative disc disease (CDDD). METHODS: Twenty-four patients with PEEK cages coated with Ti and HA (PEEK/Ti/HA group) were matched one-to-one with patients with uncoated PEEK cages (PEEK group) based on age, gender, and operative segment. All patients had been followed up for more than 2 years. Radiological assessments included intervertebral height (IH), C2-7 angle (C2-7a), segmental alignment (SA), and fusion rate. Clinical parameters included Visual Analogue Scale (VAS) and Japanese Orthopedic Association (JOA) scores. RESULTS: There was no statistical difference in SA, IH, and C2-7a between the two groups before and after surgery and all these parameters were restored postoperatively. The fusion rate of PEEK/Ti/HA group was significantly higher than PEEK group at 3-month post-operation (87.5% vs. 62.5%). At the last follow-up, the fusion rate of the both groups achieved 100%. The VAS and JOA scores were comparable between two groups and improved postoperatively. CONCLUSIONS: In patients with single-level ACDF, PEEK cage coated with Ti and HA provided a higher fusion rate than uncoated PEEK cage at 3-month post-operation, while both two cages could achieve solid osseous fusion at the last follow up. Compared with the uncoated PEEK cage, PEEK/Ti/HA cage yielded similar favorable segmental and overall cervical lordosis, IH, and clinical outcomes after the surgery. BioMed Central 2021-01-06 /pmc/articles/PMC7788895/ /pubmed/33407627 http://dx.doi.org/10.1186/s12967-020-02688-z Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Zhu, Ce He, Miaomiao Mao, Lili Li, Tao Zhang, Li Liu, Limin Feng, Ganjun Song, Yueming Titanium-interlayer mediated hydroxyapatite coating on polyetheretherketone: a prospective study in patients with single-level cervical degenerative disc disease |
title | Titanium-interlayer mediated hydroxyapatite coating on polyetheretherketone: a prospective study in patients with single-level cervical degenerative disc disease |
title_full | Titanium-interlayer mediated hydroxyapatite coating on polyetheretherketone: a prospective study in patients with single-level cervical degenerative disc disease |
title_fullStr | Titanium-interlayer mediated hydroxyapatite coating on polyetheretherketone: a prospective study in patients with single-level cervical degenerative disc disease |
title_full_unstemmed | Titanium-interlayer mediated hydroxyapatite coating on polyetheretherketone: a prospective study in patients with single-level cervical degenerative disc disease |
title_short | Titanium-interlayer mediated hydroxyapatite coating on polyetheretherketone: a prospective study in patients with single-level cervical degenerative disc disease |
title_sort | titanium-interlayer mediated hydroxyapatite coating on polyetheretherketone: a prospective study in patients with single-level cervical degenerative disc disease |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7788895/ https://www.ncbi.nlm.nih.gov/pubmed/33407627 http://dx.doi.org/10.1186/s12967-020-02688-z |
work_keys_str_mv | AT zhuce titaniuminterlayermediatedhydroxyapatitecoatingonpolyetheretherketoneaprospectivestudyinpatientswithsinglelevelcervicaldegenerativediscdisease AT hemiaomiao titaniuminterlayermediatedhydroxyapatitecoatingonpolyetheretherketoneaprospectivestudyinpatientswithsinglelevelcervicaldegenerativediscdisease AT maolili titaniuminterlayermediatedhydroxyapatitecoatingonpolyetheretherketoneaprospectivestudyinpatientswithsinglelevelcervicaldegenerativediscdisease AT litao titaniuminterlayermediatedhydroxyapatitecoatingonpolyetheretherketoneaprospectivestudyinpatientswithsinglelevelcervicaldegenerativediscdisease AT zhangli titaniuminterlayermediatedhydroxyapatitecoatingonpolyetheretherketoneaprospectivestudyinpatientswithsinglelevelcervicaldegenerativediscdisease AT liulimin titaniuminterlayermediatedhydroxyapatitecoatingonpolyetheretherketoneaprospectivestudyinpatientswithsinglelevelcervicaldegenerativediscdisease AT fengganjun titaniuminterlayermediatedhydroxyapatitecoatingonpolyetheretherketoneaprospectivestudyinpatientswithsinglelevelcervicaldegenerativediscdisease AT songyueming titaniuminterlayermediatedhydroxyapatitecoatingonpolyetheretherketoneaprospectivestudyinpatientswithsinglelevelcervicaldegenerativediscdisease |