Cargando…
The effect of breast density on the missed lesion rate in screening digital mammography determined using an adjustable-density breast phantom tailored to Japanese women
OBJECTIVE: Despite the high risk of missing lesions in mammography, the missed lesion rate is yet to be clinically established. Further, no breast phantoms with adjustable breast density currently exist. We developed a novel, adjustable-density breast phantom with a composition identical to that of...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7790234/ https://www.ncbi.nlm.nih.gov/pubmed/33411847 http://dx.doi.org/10.1371/journal.pone.0245060 |
_version_ | 1783633378416787456 |
---|---|
author | Yamamuro, Mika Asai, Yoshiyuki Hashimoto, Naomi Yasuda, Nao Ozaki, Yoshiaki Ishii, Kazunari Lee, Yongbum |
author_facet | Yamamuro, Mika Asai, Yoshiyuki Hashimoto, Naomi Yasuda, Nao Ozaki, Yoshiaki Ishii, Kazunari Lee, Yongbum |
author_sort | Yamamuro, Mika |
collection | PubMed |
description | OBJECTIVE: Despite the high risk of missing lesions in mammography, the missed lesion rate is yet to be clinically established. Further, no breast phantoms with adjustable breast density currently exist. We developed a novel, adjustable-density breast phantom with a composition identical to that of actual breasts, and determined the quantitative relationship between breast density and the missed lesion rate in mammography. METHODS: An original breast phantom consisting of adipose- and fibroglandular-equivalent materials was developed, and a receiver operating characteristic (ROC) study was performed. Breast density, which is the fraction by weight of fibroglandular to total tissue, was adjusted to 25%, 50%, and 75% by arbitrarily mixing the two materials. Microcalcification, mass lesions, and spiculated lesions, each with unique characteristics, were inserted into the phantom. For the above-mentioned fibroglandular densities, 50 positive and 50 negative images for each lesion type were used as case samples for the ROC study. Five certified radiological technologists participated in lesion detection. RESULTS: The mass-lesion detection rate, according to the area under the curve, decreased by 18.0% (p = 0.0001, 95% Confidence intervals [CI] = 0.1258 to 0.1822) and 37.8% (p = 0.0003, 95% CI = 0.2453 to 0.4031) for breast densities of 50% and 75%, respectively, compared to that for a 25% breast density. A similar tendency was observed with microcalcification; however, spiculated lesions did not follow this tendency. CONCLUSIONS: We quantified the missed lesion rate in different densities of breast tissue using a novel breast phantom, which is imperative for advancing individualized screening mammography. |
format | Online Article Text |
id | pubmed-7790234 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-77902342021-01-14 The effect of breast density on the missed lesion rate in screening digital mammography determined using an adjustable-density breast phantom tailored to Japanese women Yamamuro, Mika Asai, Yoshiyuki Hashimoto, Naomi Yasuda, Nao Ozaki, Yoshiaki Ishii, Kazunari Lee, Yongbum PLoS One Research Article OBJECTIVE: Despite the high risk of missing lesions in mammography, the missed lesion rate is yet to be clinically established. Further, no breast phantoms with adjustable breast density currently exist. We developed a novel, adjustable-density breast phantom with a composition identical to that of actual breasts, and determined the quantitative relationship between breast density and the missed lesion rate in mammography. METHODS: An original breast phantom consisting of adipose- and fibroglandular-equivalent materials was developed, and a receiver operating characteristic (ROC) study was performed. Breast density, which is the fraction by weight of fibroglandular to total tissue, was adjusted to 25%, 50%, and 75% by arbitrarily mixing the two materials. Microcalcification, mass lesions, and spiculated lesions, each with unique characteristics, were inserted into the phantom. For the above-mentioned fibroglandular densities, 50 positive and 50 negative images for each lesion type were used as case samples for the ROC study. Five certified radiological technologists participated in lesion detection. RESULTS: The mass-lesion detection rate, according to the area under the curve, decreased by 18.0% (p = 0.0001, 95% Confidence intervals [CI] = 0.1258 to 0.1822) and 37.8% (p = 0.0003, 95% CI = 0.2453 to 0.4031) for breast densities of 50% and 75%, respectively, compared to that for a 25% breast density. A similar tendency was observed with microcalcification; however, spiculated lesions did not follow this tendency. CONCLUSIONS: We quantified the missed lesion rate in different densities of breast tissue using a novel breast phantom, which is imperative for advancing individualized screening mammography. Public Library of Science 2021-01-07 /pmc/articles/PMC7790234/ /pubmed/33411847 http://dx.doi.org/10.1371/journal.pone.0245060 Text en © 2021 Yamamuro et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Yamamuro, Mika Asai, Yoshiyuki Hashimoto, Naomi Yasuda, Nao Ozaki, Yoshiaki Ishii, Kazunari Lee, Yongbum The effect of breast density on the missed lesion rate in screening digital mammography determined using an adjustable-density breast phantom tailored to Japanese women |
title | The effect of breast density on the missed lesion rate in screening digital mammography determined using an adjustable-density breast phantom tailored to Japanese women |
title_full | The effect of breast density on the missed lesion rate in screening digital mammography determined using an adjustable-density breast phantom tailored to Japanese women |
title_fullStr | The effect of breast density on the missed lesion rate in screening digital mammography determined using an adjustable-density breast phantom tailored to Japanese women |
title_full_unstemmed | The effect of breast density on the missed lesion rate in screening digital mammography determined using an adjustable-density breast phantom tailored to Japanese women |
title_short | The effect of breast density on the missed lesion rate in screening digital mammography determined using an adjustable-density breast phantom tailored to Japanese women |
title_sort | effect of breast density on the missed lesion rate in screening digital mammography determined using an adjustable-density breast phantom tailored to japanese women |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7790234/ https://www.ncbi.nlm.nih.gov/pubmed/33411847 http://dx.doi.org/10.1371/journal.pone.0245060 |
work_keys_str_mv | AT yamamuromika theeffectofbreastdensityonthemissedlesionrateinscreeningdigitalmammographydeterminedusinganadjustabledensitybreastphantomtailoredtojapanesewomen AT asaiyoshiyuki theeffectofbreastdensityonthemissedlesionrateinscreeningdigitalmammographydeterminedusinganadjustabledensitybreastphantomtailoredtojapanesewomen AT hashimotonaomi theeffectofbreastdensityonthemissedlesionrateinscreeningdigitalmammographydeterminedusinganadjustabledensitybreastphantomtailoredtojapanesewomen AT yasudanao theeffectofbreastdensityonthemissedlesionrateinscreeningdigitalmammographydeterminedusinganadjustabledensitybreastphantomtailoredtojapanesewomen AT ozakiyoshiaki theeffectofbreastdensityonthemissedlesionrateinscreeningdigitalmammographydeterminedusinganadjustabledensitybreastphantomtailoredtojapanesewomen AT ishiikazunari theeffectofbreastdensityonthemissedlesionrateinscreeningdigitalmammographydeterminedusinganadjustabledensitybreastphantomtailoredtojapanesewomen AT leeyongbum theeffectofbreastdensityonthemissedlesionrateinscreeningdigitalmammographydeterminedusinganadjustabledensitybreastphantomtailoredtojapanesewomen AT yamamuromika effectofbreastdensityonthemissedlesionrateinscreeningdigitalmammographydeterminedusinganadjustabledensitybreastphantomtailoredtojapanesewomen AT asaiyoshiyuki effectofbreastdensityonthemissedlesionrateinscreeningdigitalmammographydeterminedusinganadjustabledensitybreastphantomtailoredtojapanesewomen AT hashimotonaomi effectofbreastdensityonthemissedlesionrateinscreeningdigitalmammographydeterminedusinganadjustabledensitybreastphantomtailoredtojapanesewomen AT yasudanao effectofbreastdensityonthemissedlesionrateinscreeningdigitalmammographydeterminedusinganadjustabledensitybreastphantomtailoredtojapanesewomen AT ozakiyoshiaki effectofbreastdensityonthemissedlesionrateinscreeningdigitalmammographydeterminedusinganadjustabledensitybreastphantomtailoredtojapanesewomen AT ishiikazunari effectofbreastdensityonthemissedlesionrateinscreeningdigitalmammographydeterminedusinganadjustabledensitybreastphantomtailoredtojapanesewomen AT leeyongbum effectofbreastdensityonthemissedlesionrateinscreeningdigitalmammographydeterminedusinganadjustabledensitybreastphantomtailoredtojapanesewomen |